Literature DB >> 11021692

Resolution and noise properties of MAP reconstruction for fully 3-D PET.

J Qi1, R M Leahy.   

Abstract

We derive approximate analytical expressions for the local impulse response and covariance of images reconstructed from fully three-dimensional (3-D) positron emission tomography (PET) data using maximum a posteriori (MAP) estimation. These expressions explicitly account for the spatially variant detector response and sensitivity of a 3-D tomograph. The resulting spatially variant impulse response and covariance are computed using 3-D Fourier transforms. A truncated Gaussian distribution is used to account for the effect on the variance of the nonnegativity constraint used in MAP reconstruction. Using Monte Carlo simulations and phantom data from the microPET small animal scanner, we show that the approximations provide reasonably accurate estimates of contrast recovery and covariance of MAP reconstruction for priors with quadratic energy functions. We also describe how these analytical results can be used to achieve near-uniform contrast recovery throughout the reconstructed volume.

Mesh:

Year:  2000        PMID: 11021692     DOI: 10.1109/42.870259

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  92 in total

1.  Quantitative, simultaneous PET/MRI for intratumoral imaging with an MRI-compatible PET scanner.

Authors:  Thomas S C Ng; James R Bading; Ryan Park; Hargun Sohi; Daniel Procissi; David Colcher; Peter S Conti; Simon R Cherry; Andrew A Raubitschek; Russell E Jacobs
Journal:  J Nucl Med       Date:  2012-06-01       Impact factor: 10.057

2.  Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT.

Authors:  Jang Hwan Cho; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-10-28       Impact factor: 10.048

Review 3.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

4.  Rapid Computation of LROC Figures of Merit Using Numerical Observers (for SPECT/PET Reconstruction).

Authors:  Parmeshwar Khurd; Gene Gindi
Journal:  IEEE Trans Nucl Sci       Date:  2003       Impact factor: 1.679

5.  Rapid Optimization of SPECT Scatter Correction Using Model LROC Observers.

Authors:  Santosh Kulkarni; Parmeshwar Khurd; Lili Zhou; Gene Gindi
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

6.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

7.  Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-30       Impact factor: 9.236

8.  PET Performance Evaluation of an MR-Compatible PET Insert.

Authors:  Yibao Wu; Ciprian Catana; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

9.  Sparsity Constrained Mixture Modeling for the Estimation of Kinetic Parameters in Dynamic PET.

Authors:  Yanguang Lin; Justin P Haldar; Quanzheng Li; Peter S Conti; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2013-11-07       Impact factor: 10.048

10.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.