Literature DB >> 30840723

Small animal, positron emission tomography-magnetic resonance imaging system based on a clinical magnetic resonance imaging scanner: evaluation of basic imaging performance.

Raymond R Raylman1, Patrick Ledden2, Alexander V Stolin1, Bob Hou1, Ganghadar Jaliparthi1, Peter F Martone1.   

Abstract

Development of advanced preclinical imaging techniques has had an important impact on the field of biomedical research, with positron emission tomography (PET) imaging the most mature of these efforts. Developers of preclinical PET scanners have joined the recent multimodality imaging trend by combining PET imaging with other modalities, such as magnetic resonance imaging (MRI). Our group has developed a combined PET-MRI insert for the imaging of animals up to the size of rats in a clinical 3T MRI scanner. The system utilizes a sequential scanner configuration instead of the more common coplanar geometry. The PET component of the system consists of a ring of 12 liquid-cooled, SiPM-based detector modules ( diameter = 15.2    cm ). System performance was evaluated with the NEMA NU 4-2008 protocol. Spatial resolution is ∼ 1.71    mm 5 cm from the center of the field-of-view measured from single-slice rebinned filtered backprojection-reconstructed images. Peak noise equivalent count rate is 17.7 kcps at 8.5 MBq; peak sensitivity is 2.9%. The MRI component of the system is composed of a 12-cm-diameter birdcage transmit/receive coil with a dual-preamplifier interface possessing very low noise preamplifiers. System performance was evaluated using American College of Radiology-based methods. Image homogeneity is 99%; the ghosting ratio is 0.0054. The signal-to-noise ratio is 95 and spatial resolution is ∼ 0.25    mm . There was no discernable cross-modality interference.

Entities:  

Keywords:  magnetic resonance imaging; positron emission tomography; preclinical

Year:  2018        PMID: 30840723      PMCID: PMC6129179          DOI: 10.1117/1.JMI.5.3.033504

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  36 in total

1.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging.

Authors:  A F Chatziioannou; S R Cherry; Y Shao; R W Silverman; K Meadors; T H Farquhar; M Pedarsani; M E Phelps
Journal:  J Nucl Med       Date:  1999-07       Impact factor: 10.057

2.  AMIDE: a free software tool for multimodality medical image analysis.

Authors:  Andreas Markus Loening; Sanjiv Sam Gambhir
Journal:  Mol Imaging       Date:  2003-07       Impact factor: 4.488

3.  Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations.

Authors:  Mark F Smith; Raymond R Raylman; Stan Majewski; Andrew G Weisenberger
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

4.  PET Performance Evaluation of an MR-Compatible PET Insert.

Authors:  Yibao Wu; Ciprian Catana; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

5.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

6.  Simultaneous MRI and PET imaging of a rat brain.

Authors:  Raymond R Raylman; Stan Majewski; Susan K Lemieux; S Sendhil Velan; Brian Kross; Vladimir Popov; Mark F Smith; Andrew G Weisenberger; Carl Zorn; Gary D Marano
Journal:  Phys Med Biol       Date:  2006-11-23       Impact factor: 3.609

7.  Development of small-animal PET prototype using silicon photomultiplier (SiPM): initial results of phantom and animal imaging studies.

Authors:  Sun Il Kwon; Jae Sung Lee; Hyun Suk Yoon; Mikiko Ito; Guen Bae Ko; Jae Yeon Choi; Sung-Hyuk Lee; In Chan Song; Jae Min Jeong; Dong Soo Lee; Seong Jong Hong
Journal:  J Nucl Med       Date:  2011-03-18       Impact factor: 10.057

8.  In vivo fiber tracking in the rat brain on a clinical 3T MRI system using a high strength insert gradient coil.

Authors:  Dirk Mayer; Natalie M Zahr; Elfar Adalsteinsson; Brian Rutt; Edith V Sullivan; Adolf Pfefferbaum
Journal:  Neuroimage       Date:  2007-01-25       Impact factor: 6.556

9.  In vivo visualization of endolymphatic hydrops in guinea pigs: magnetic resonance imaging evaluation at 4.7 tesla.

Authors:  Jing Zou; Ilmari Pyykkö; Poul Bretlau; Tomas Klason; Börje Bjelke
Journal:  Ann Otol Rhinol Laryngol       Date:  2003-12       Impact factor: 1.547

10.  In vivo magnetic resonance imaging of iron oxide-labeled, arterially-injected mesenchymal stem cells in kidneys of rats with acute ischemic kidney injury: detection and monitoring at 3T.

Authors:  Harald Ittrich; Claudia Lange; Florian Tögel; Axel R Zander; Hannes Dahnke; Christof Westenfelder; Gerhard Adam; Claus Nolte-Ernsting
Journal:  J Magn Reson Imaging       Date:  2007-06       Impact factor: 4.813

View more
  1 in total

1.  Evaluations of the performances of PET and MRI in a simultaneous PET/MRI instrument for pre-clinical imaging.

Authors:  Alyssa C Pollard; Jorge de la Cerda; F William Schuler; Charles V Kingsley; Seth T Gammon; Mark D Pagel
Journal:  EJNMMI Phys       Date:  2022-10-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.