Quantitative Accuracy of HRRT List-mode Reconstructions: Effect of Low Statistics.

Beata Planeta-Wilson1, Jianhua Yan, Tim Mulnix, Richard E Carson.   

Abstract

Previous studies showed that iterative image reconstruction algorithms may produce overestimations of activity in low-activity regions in low-count frames. The purpose of this study was (1) to evaluate the quantitative accuracy of the MOLAR list-mode iterative reconstruction method in the context of ligand-receptor PET studies in low counts, and (2) to determine the minimum noise equivalent counts (NEC) per frame to avoid bias. Evaluation of clinical data was performed for 4 tracers using dynamic brain PET studies. True activity was estimated from high-statistics frames (300s) and ROI analysis was performed to evaluate bias in low-activity regions in short acquisition frames (10-30s) from matching times. Bias in the ROI mean values was analyzed as function of NEC. In addition, accuracy was assessed using Hoffman phantom data and simulated list mode data based on human data, but without scatter and randoms.Unlike previous results, small biases of -3±3% for low statistics region across the 4 tracers were found for NEC >100K in each frame. Very similar results were found in the phantom and simulation data. We conclude that the MOLAR iterative reconstruction method provides accurate results even in very low-count frames. This improved performance may be attributed to some of the unique characteristics of MOLAR including randoms estimation from singles, iterative estimation of scatter within the algorithm, component-based normalization, and incorporation of a line-spread function model in the reconstruction.

Entities:  

Year:  2008        PMID: 20617118      PMCID: PMC2898285          DOI: 10.1109/NSSMIC.2008.4774388

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  5 in total

1.  Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single-subject brain.

Authors:  N Tzourio-Mazoyer; B Landeau; D Papathanassiou; F Crivello; O Etard; N Delcroix; B Mazoyer; M Joliot
Journal:  Neuroimage       Date:  2002-01       Impact factor: 6.556

2.  Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for High-Resolution Research Tomograph studies: effects of randoms estimation methods.

Authors:  Floris H P van Velden; Reina W Kloet; Bart N M van Berckel; Saskia P A Wolfensberger; Adriaan A Lammertsma; Ronald Boellaard
Journal:  Phys Med Biol       Date:  2008-05-27       Impact factor: 3.609

3.  Quantitation in positron emission computed tomography: 4. Effect of accidental coincidences.

Authors:  E J Hoffman; S C Huang; M E Phelps; D E Kuhl
Journal:  J Comput Assist Tomogr       Date:  1981-06       Impact factor: 1.826

4.  Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies.

Authors:  Anthonin Reilhac; Sandrine Tomeï; Irène Buvat; Christian Michel; Frank Keheren; Nicolas Costes
Journal:  Neuroimage       Date:  2007-08-09       Impact factor: 6.556

5.  Tracer kinetic modeling of [(11)C]AFM, a new PET imaging agent for the serotonin transporter.

Authors:  Mika Naganawa; Nabeel Nabulsi; Beata Planeta; Jean-Dominique Gallezot; Shu-Fei Lin; Soheila Najafzadeh; Wendol Williams; Jim Ropchan; David Labaree; Alexander Neumeister; Yiyun Huang; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2013-08-07       Impact factor: 6.200

  5 in total
  10 in total

1.  Initial Evaluation of Direct 4D Parametric Reconstruction with Human PET Data.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Jean-Dominique Gallezot; Richard E Carson
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-11-01

2.  Reproducibility of striatal and thalamic dopamine D2 receptor binding using [11C]raclopride with high-resolution positron emission tomography.

Authors:  Kati Alakurtti; Sargo Aalto; Jarkko J Johansson; Kjell Någren; Terhi Tuokkola; Vesa Oikonen; Matti Laine; Juha O Rinne
Journal:  J Cereb Blood Flow Metab       Date:  2010-05-05       Impact factor: 6.200

3.  Evaluation of bias and variance in low-count OSEM list mode reconstruction.

Authors:  Y Jian; B Planeta; R E Carson
Journal:  Phys Med Biol       Date:  2014-12-05       Impact factor: 3.609

4.  PET Imaging of Leg Arteries for Determining the Input Function in PET/MRI Brain Studies Using a Compact, MRI-compatible PET System.

Authors:  Shouyi Wei; Nandita Joshi; Michael Salerno; David Ouellette; Lemise Saleh; Christine DeLorenzo; Craig Woody; David Schlyer; Martin L Purschke; Jean-Francois Pratte; Sachin Junnarkar; Michael Budassi; Tuoyu Cao; Jack Fried; Joel S Karp; Paul Vaska
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-09-13

5.  Evaluation of frame-based and event-by-event motion-correction methods for awake monkey brain PET imaging.

Authors:  Xiao Jin; Tim Mulnix; Christine M Sandiego; Richard E Carson
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

6.  Kinetic modeling of the serotonin 5-HT(1B) receptor radioligand [(11)C]P943 in humans.

Authors:  Jean-Dominique Gallezot; Nabeel Nabulsi; Alexander Neumeister; Beata Planeta-Wilson; Wendol A Williams; Tarun Singhal; Sunhee Kim; R Paul Maguire; Timothy McCarthy; J James Frost; Yiyun Huang; Yu-Shin Ding; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2009-09-23       Impact factor: 6.200

7.  Cerebral blood flow with [15O]water PET studies using an image-derived input function and MR-defined carotid centerlines.

Authors:  Edward K Fung; Richard E Carson
Journal:  Phys Med Biol       Date:  2013-02-27       Impact factor: 3.609

8.  Direct 4-D PET list mode parametric reconstruction with a novel EM algorithm.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Richard E Carson
Journal:  IEEE Trans Med Imaging       Date:  2012-08-23       Impact factor: 10.048

9.  Bias evaluation and reduction in 3D OP-OSEM reconstruction in dynamic equilibrium PET studies with 11C-labeled for binding potential analysis.

Authors:  Cláudia Régio Brambilla; Jürgen Scheins; Ahlam Issa; Lutz Tellmann; Hans Herzog; Elena Rota Kops; N Jon Shah; Irene Neuner; Christoph W Lerche
Journal:  PLoS One       Date:  2021-01-22       Impact factor: 3.240

10.  Reconstruction of positron emission tomography images using adaptive sliced remeshing strategy.

Authors:  Ramiro R Colmeiro; Claudio Verrastro; Daniel Minsky; Thomas Grosges
Journal:  J Med Imaging (Bellingham)       Date:  2021-03-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.