Literature DB >> 18506070

Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for High-Resolution Research Tomograph studies: effects of randoms estimation methods.

Floris H P van Velden1, Reina W Kloet, Bart N M van Berckel, Saskia P A Wolfensberger, Adriaan A Lammertsma, Ronald Boellaard.   

Abstract

The High-Resolution Research Tomograph (HRRT) is a dedicated human brain positron emission tomography (PET) scanner. Recently, a 3D filtered backprojection (3D-FBP) reconstruction method has been implemented to reduce bias in short duration frames, currently observed in 3D ordinary Poisson OSEM (3D-OP-OSEM) reconstructions. Further improvements might be expected using a new method of variance reduction on randoms (VRR) based on coincidence histograms instead of using the delayed window technique (DW) to estimate randoms. The goal of this study was to evaluate VRR in combination with 3D-OP-OSEM and 3D-FBP reconstruction techniques. To this end, several phantom studies and a human brain study were performed. For most phantom studies, 3D-OP-OSEM showed higher accuracy of observed activity concentrations with VRR than with DW. However, both positive and negative deviations in reconstructed activity concentrations and large biases of grey to white matter contrast ratio (up to 88%) were still observed as a function of scan statistics. Moreover 3D-OP-OSEM+VRR also showed bias up to 64% in clinical data, i.e. in some pharmacokinetic parameters as compared with those obtained with 3D-FBP+VRR. In the case of 3D-FBP, VRR showed similar results as DW for both phantom and clinical data, except that VRR showed a better standard deviation of 6-10%. Therefore, VRR should be used to correct for randoms in HRRT PET studies.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18506070     DOI: 10.1088/0031-9155/53/12/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Quantitative Accuracy of HRRT List-mode Reconstructions: Effect of Low Statistics.

Authors:  Beata Planeta-Wilson; Jianhua Yan; Tim Mulnix; Richard E Carson
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008-10-01

2.  Evaluation of motion correction methods in human brain PET imaging--a simulation study based on human motion data.

Authors:  Xiao Jin; Tim Mulnix; Jean-Dominique Gallezot; Richard E Carson
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  Reproducibility of striatal and thalamic dopamine D2 receptor binding using [11C]raclopride with high-resolution positron emission tomography.

Authors:  Kati Alakurtti; Sargo Aalto; Jarkko J Johansson; Kjell Någren; Terhi Tuokkola; Vesa Oikonen; Matti Laine; Juha O Rinne
Journal:  J Cereb Blood Flow Metab       Date:  2010-05-05       Impact factor: 6.200

4.  Comparison of HRRT and HR+ scanners for quantitative (R)-[11C]verapamil, [11C]raclopride and [11C]flumazenil brain studies.

Authors:  Floris H P van Velden; Syahir M Mansor; Daniëlle M E van Assema; Bart N M van Berckel; Femke E Froklage; Shaonan Wang; Robert C Schuit; Marie-Claude Asselin; Adriaan A Lammertsma; Ronald Boellaard; Marc C Huisman
Journal:  Mol Imaging Biol       Date:  2015-02       Impact factor: 3.488

5.  Effect of Scan Time on Oncologic Lesion Detection in Whole-Body PET.

Authors:  Dan J Kadrmas; M Bugrahan Oktay; Michael E Casey; James J Hamill
Journal:  IEEE Trans Nucl Sci       Date:  2012-10       Impact factor: 1.679

6.  Bias reduction for low-statistics PET: maximum likelihood reconstruction with a modified Poisson distribution.

Authors:  Katrien Van Slambrouck; Simon Stute; Claude Comtat; Merence Sibomana; Floris H P van Velden; Ronald Boellaard; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2014-08-14       Impact factor: 10.048

7.  Test-Retest Reliability of the SERT Imaging Agent 11C-HOMADAM in Healthy Humans.

Authors:  Vikram Adhikarla; Boadie W Dunlop; Nashwa Jarkas; Mark M Goodman; Helen Mayberg; Michael J Owens; Jonathon A Nye
Journal:  J Nucl Med       Date:  2017-09-21       Impact factor: 10.057

8.  Evaluation of frame-based and event-by-event motion-correction methods for awake monkey brain PET imaging.

Authors:  Xiao Jin; Tim Mulnix; Christine M Sandiego; Richard E Carson
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

9.  Kinetic modeling of the serotonin 5-HT(1B) receptor radioligand [(11)C]P943 in humans.

Authors:  Jean-Dominique Gallezot; Nabeel Nabulsi; Alexander Neumeister; Beata Planeta-Wilson; Wendol A Williams; Tarun Singhal; Sunhee Kim; R Paul Maguire; Timothy McCarthy; J James Frost; Yiyun Huang; Yu-Shin Ding; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2009-09-23       Impact factor: 6.200

10.  Analytic TOF PET reconstruction algorithm within DIRECT data partitioning framework.

Authors:  Samuel Matej; Margaret E Daube-Witherspoon; Joel S Karp
Journal:  Phys Med Biol       Date:  2016-04-01       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.