Literature DB >> 33681408

Reconstruction of positron emission tomography images using adaptive sliced remeshing strategy.

Ramiro R Colmeiro1,2,3, Claudio Verrastro2,4, Daniel Minsky3,4, Thomas Grosges1.   

Abstract

Purpose: The reconstruction of positron emission tomography images is a computationally intensive task which benefits from the use of increasingly complex physical models. Aiming to reduce the computational burden by means of a reduced system matrix, we present a list mode reconstruction approach based on maximum likelihood-expectation maximization and a sliced mesh support. Approach: The reconstruction strategy uses a fully 3D projection along series of 2D meshes arranged in the axial plane of the scanner. These series of meshes describe the continuous volumetric activity using a piece-wise linear function interpolated from the mesh elements. The mesh support is automatically adapted to the underlying structure of the activity by means of a remeshing process. This process finds a high-quality compact mesh representation constrained to a controlled interpolation error.
Results: The method is tested using a Monte Carlo simulation of a Hoffman brain phantom and a National Electrical Manufacturers Association image quality phantom acquisition, using different sets of statistics. The reconstructions are compared against a voxelized reconstruction under different conditions, achieving similar or superior results. The number of parameters needed to reconstruct the image in voxel and mesh support is also compared, and the mesh reconstruction permits to reduce the number of nodes used to represent a complex image. Conclusions: The proposed reconstruction strategy reduces the number of parameters needed to describe the activity distribution by more than one order of magnitude for similar voxel size and with similar accuracy than state-of-the-art methods.
© 2021 Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  compact representation; expectation maximization; iterative reconstruction; list mode; mesh modeling; positron emission tomography

Year:  2021        PMID: 33681408      PMCID: PMC7920386          DOI: 10.1117/1.JMI.8.2.024001

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  16 in total

1.  Tomographic image reconstruction based on a content-adaptive mesh model.

Authors:  Jovan G Brankov; Yongyi Yang; Miles N Wernick
Journal:  IEEE Trans Med Imaging       Date:  2004-02       Impact factor: 10.048

2.  Tomographic reconstruction using an adaptive tetrahedral mesh defined by a point cloud.

Authors:  Arkadiusz Sitek; Ronald H Huesman; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2006-09       Impact factor: 10.048

3.  Conditional entropy maximization for PET image reconstruction using adaptive mesh model.

Authors:  Hongqing Zhu; Huazhong Shu; Jian Zhou; Xiubin Dai; Limin Luo
Journal:  Comput Med Imaging Graph       Date:  2007-04       Impact factor: 4.790

4.  Improved scheme for accurate computation of high electric near-field gradients.

Authors:  Thomas Grosges; Houman Borouchaki; Dominique Barchiesi
Journal:  Opt Express       Date:  2007-02-05       Impact factor: 3.894

5.  List-mode image reconstruction for positron emission tomography using tetrahedral voxels.

Authors:  John E Gillam; Georgios I Angelis; Steven R Meikle
Journal:  Phys Med Biol       Date:  2016-08-23       Impact factor: 3.609

6.  Significant dose reduction is feasible in FDG PET/CT protocols without compromising diagnostic quality.

Authors:  Elena Prieto; María José García-Velloso; Macarena Rodríguez-Fraile; Verónica Morán; Berta García-García; Fernando Guillén; María Isabel Morales; Lidia Sancho; Iván Peñuelas; José Ángel Richter; Josep María Martí-Climent
Journal:  Phys Med       Date:  2018-02-06       Impact factor: 2.685

7.  Evaluation of a 3D point cloud tetrahedral tomographic reconstruction method.

Authors:  N F Pereira; A Sitek
Journal:  Phys Med Biol       Date:  2010-08-24       Impact factor: 3.609

8.  Bias in iterative reconstruction of low-statistics PET data: benefits of a resolution model.

Authors:  M D Walker; M-C Asselin; P J Julyan; M Feldmann; P S Talbot; T Jones; J C Matthews
Journal:  Phys Med Biol       Date:  2011-01-20       Impact factor: 3.609

9.  Practical implementation of tetrahedral mesh reconstruction in emission tomography.

Authors:  R Boutchko; A Sitek; G T Gullberg
Journal:  Phys Med Biol       Date:  2013-04-15       Impact factor: 3.609

10.  Zero-Extra-Dose PET Delayed Imaging with Data-Driven Attenuation Correction Estimation.

Authors:  Lifang Pang; Wentao Zhu; Yun Dong; Yang Lv; Hongcheng Shi
Journal:  Mol Imaging Biol       Date:  2019-02       Impact factor: 3.488

View more