Literature DB >> 21278923

Initial Evaluation of Direct 4D Parametric Reconstruction with Human PET Data.

Jianhua Yan1, Beata Planeta-Wilson, Jean-Dominique Gallezot, Richard E Carson.   

Abstract

Previously, we presented a direct EM method for producing kinetic parameter images from list mode PET data, where the time-activity curve for each voxel is described by a one-tissue compartment model (1T). The initial evaluations were performed with simulations, without motion, randoms, or scatter effects included. By extension of our previous frame-based physics correction methods, a practical direct 4D parametric reconstruction algorithm is now proposed and implemented for human data. Initial evaluations were performed using 3 human subjects with the serotonin transporter tracer [(11)C]AFM. Comparisons with the 2-step approach (frame-based reconstruction followed by voxel-by-voxel parameter estimation) provided encouraging initial results. Regional analysis showed that the 2-step and 4D methods have similar K(1) and V(T) values, but with a consistent difference. Visual analysis showed some noise reduction in 4D. These initial results suggest that direct 4D parametric reconstruction can be performed with real data, and offers the potential for improved accuracy and precision over the 2-step frame method.

Entities:  

Year:  2009        PMID: 21278923      PMCID: PMC3030204          DOI: 10.1109/NSSMIC.2009.5402049

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  6 in total

1.  Quantitative Accuracy of HRRT List-mode Reconstructions: Effect of Low Statistics.

Authors:  Beata Planeta-Wilson; Jianhua Yan; Tim Mulnix; Richard E Carson
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008-10-01

2.  Direct 4D List Mode Parametric Reconstruction for PET with a Novel EM Algorithm.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Richard E Carson
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008

3.  Direct reconstruction of kinetic parameter images from dynamic PET data.

Authors:  M E Kamasak; C A Bouman; E D Morris; K Sauer
Journal:  IEEE Trans Med Imaging       Date:  2005-05       Impact factor: 10.048

4.  Maximum a posteriori reconstruction of the Patlak parametric image from sinograms in dynamic PET.

Authors:  Guobao Wang; Lin Fu; Jinyi Qi
Journal:  Phys Med Biol       Date:  2008-01-10       Impact factor: 3.609

5.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.

Authors:  Charalampos Tsoumpas; Federico E Turkheimer; Kris Thielemans
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

6.  Generalized algorithms for direct reconstruction of parametric images from dynamic PET data.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

  6 in total
  2 in total

1.  Direct reconstruction of parametric images for brain PET with event-by-event motion correction: evaluation in two tracers across count levels.

Authors:  Mary Germino; Jean-Dominque Gallezot; Jianhua Yan; Richard E Carson
Journal:  Phys Med Biol       Date:  2017-05-15       Impact factor: 3.609

2.  Direct 4-D PET list mode parametric reconstruction with a novel EM algorithm.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Richard E Carson
Journal:  IEEE Trans Med Imaging       Date:  2012-08-23       Impact factor: 10.048

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.