Literature DB >> 22055851

A dual-tuned quadrature volume coil with mixed λ/2 and λ/4 microstrip resonators for multinuclear MRSI at 7 T.

Yong Pang1, Zhentian Xie, Duan Xu, Douglas A Kelley, Sarah J Nelson, Daniel B Vigneron, Xiaoliang Zhang.   

Abstract

In this work, an eight-element by eight-element dual-tuned quadrature volume coil with a mix of capacitor terminated half-wavelength (λ/2) and quarter-wavelength (λ/4) microstrip resonators is proposed for multinuclear magnetic resonance imaging/spectroscopy studies at 7 T. In the proton channel, λ/2 microstrip resonators with capacitive terminations on both ends are employed for operation at higher frequency of 298.1 MHz; in the heteronucleus channel, capacitor-terminated λ/4 resonators, suitable for low frequency operations, are used to meet the low frequency requirement. This mixed structure design is particularly advantageous for high field heteronuclei magnetic resonance applications with large difference in Larmor frequency of the nuclei in question. The proposed design method makes it much easier to perform frequency tuning for heteronucleus channel using a variable capacitor with a practical capacitance range. As an example, a dual-tuned volume coil for (1)H/(13)C mouse spectroscopic imaging was proposed to demonstrate the feasibility of this method. The finite-difference time-domain method is first used to model this dual-tuned volume coil and calculate the B(1) field distributions at two frequencies. Transmission parameters (S(21)) measured between the proton channel and the carbon channel are -50 dB at 75 MHz and -35 dB at 298 MHz, showing the excellent isolation between the two channels at 7 T. The proton image and (13)C FIDCSI image of a corn oil phantom on the axial plane at 7 T demonstrate the feasibility of the proposed method. A preliminary proton image of a mouse on the sagittal plane is also acquired using the proposed dual-tuned volume coil at 7 T, illustrating a fairly uniform B(1) field and sufficient image coverage for imaging in mice.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22055851      PMCID: PMC3254778          DOI: 10.1016/j.mri.2011.09.022

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  33 in total

1.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

3.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  Design of an inductively decoupled microstrip array at 9.4 T.

Authors:  Bing Wu; Xiaoliang Zhang; Peng Qu; Gary X Shen
Journal:  J Magn Reson       Date:  2006-07-07       Impact factor: 2.229

Review 5.  Sodium MR imaging of acute and subacute stroke for assessment of tissue viability.

Authors:  Keith R Thulborn; Denise Davis; James Snyder; Howard Yonas; Amin Kassam
Journal:  Neuroimaging Clin N Am       Date:  2005-08       Impact factor: 2.264

6.  A practical double-tuned 1H/31P quadrature birdcage headcoil optimized for 31P operation.

Authors:  G B Matson; P Vermathen; T C Hill
Journal:  Magn Reson Med       Date:  1999-07       Impact factor: 4.668

7.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

Review 8.  In vivo 1H-[13C]-NMR spectroscopy of cerebral metabolism.

Authors:  Robin A de Graaf; Graeme F Mason; Anant B Patel; Kevin L Behar; Douglas L Rothman
Journal:  NMR Biomed       Date:  2003 Oct-Nov       Impact factor: 4.044

9.  1H and 31P spectroscopic imaging of epilepsy: spectroscopic and histologic correlations.

Authors:  Hoby P Hetherington; Jung H Kim; Jullie W Pan; Dennis D Spencer
Journal:  Epilepsia       Date:  2004       Impact factor: 5.864

10.  1H-localized broadband 13C NMR spectroscopy of the rat brain in vivo at 9.4 T.

Authors:  Pierre-Gilles Henry; Ivan Tkác; Rolf Gruetter
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

View more
  9 in total

1.  Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding.

Authors:  Yujuan Zhao; Tiejun Zhao; Shailesh B Raval; Narayanan Krishnamurthy; Hai Zheng; Chad T Harris; William B Handler; Blaine A Chronik; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2014-11-03       Impact factor: 4.668

2.  A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-08

3.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

4.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

5.  1 H-13 C independently tuned radiofrequency surface coil applied for in vivo hyperpolarized MRI.

Authors:  Peng Cao; Xiaoliang Zhang; Ilwoo Park; Chloe Najac; Sarah J Nelson; Sabrina Ronen; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

6.  Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.

Authors:  Omar Rutledge; Tiffany Kwak; Peng Cao; Xiaoliang Zhang
Journal:  J Magn Reson       Date:  2016-04-07       Impact factor: 2.229

7.  Multi-reception strategy with improved SNR for multichannel MR imaging.

Authors:  Bing Wu; Ye Li; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2012-08-03       Impact factor: 3.240

8.  Loss Path Influence on the MRI Radio Frequency Pulse Sequence: A Theoretical Evidence.

Authors:  Moses Emetere; A Falade
Journal:  Open Access Maced J Med Sci       Date:  2019-08-28

9.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.