Literature DB >> 2266841

The NMR phased array.

P B Roemer1, W A Edelstein, C E Hayes, S P Souza, O M Mueller.   

Abstract

We describe methods for simultaneously acquiring and subsequently combining data from a multitude of closely positioned NMR receiving coils. The approach is conceptually similar to phased array radar and ultrasound and hence we call our techniques the "NMR phased array." The NMR phased array offers the signal-to-noise ratio (SNR) and resolution of a small surface coil over fields-of-view (FOV) normally associated with body imaging with no increase in imaging time. The NMR phased array can be applied to both imaging and spectroscopy for all pulse sequences. The problematic interactions among nearby surface coils is eliminated (a) by overlapping adjacent coils to give zero mutual inductance, hence zero interaction, and (b) by attaching low input impedance preamplifiers to all coils, thus eliminating interference among next nearest and more distant neighbors. We derive an algorithm for combining the data from the phased array elements to yield an image with optimum SNR. Other techniques which are easier to implement at the cost of lower SNR are explored. Phased array imaging is demonstrated with high resolution (512 x 512, 48-cm FOV, and 32-cm FOV) spin-echo images of the thoracic and lumbar spine. Data were acquired from four-element linear spine arrays, the first made of 12-cm square coils and the second made of 8-cm square coils. When compared with images from a single 15 x 30-cm rectangular coil and identical imaging parameters, the phased array yields a 2X and 3X higher SNR at the depth of the spine (approximately 7 cm).

Mesh:

Year:  1990        PMID: 2266841     DOI: 10.1002/mrm.1910160203

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  528 in total

1.  Multiple channel phased arrays for echo planar imaging.

Authors:  G X Shen; J Wu; F E Boada
Journal:  MAGMA       Date:  2000-12       Impact factor: 2.310

2.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

3.  An analytical SMASH procedure (ASP) for sensitivity-encoded MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; P A Bottomley
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

Review 4.  Echo planar imaging's impact on modern diagnostic MR-imaging: general principles and historic facts.

Authors:  M K Stehling; L Liu
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

5.  Cardiovascular MRI probes for the outside in and for the inside out.

Authors:  P A Bottomley; E Atalar; R F Lee; K A Shunk; A Lardo
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

6.  SMASH imaging with an eight element multiplexed RF coil array.

Authors:  J A Bankson; M A Griswold; S M Wright; D K Sodickson
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

7.  Moment method analysis of mutual interaction in MRI phased array coils.

Authors:  H Fujita; J W Missal; M A Morich
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

8.  Determination of appropriate RF blocking impedance for MRI surface coils and arrays.

Authors:  A Kocharian; P J Rossman; T C Hulshizer; J P Felmlee; S J Riederer
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

9.  Investigation of complex phased array coil designs for cardiac imaging.

Authors:  M Nittka; A Haase
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

10.  A multicoil array designed for cardiac SMASH imaging.

Authors:  M A Griswold; P M Jakob; R R Edelman; D K Sodickson
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.