Literature DB >> 23775840

Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

Nikolai I Avdievich1, Jullie W Pan, Hoby P Hetherington.   

Abstract

Transceiver surface coil arrays improve transmit performance (B1/√kW) and B1 homogeneity for head imaging up to 9.4 T. To further improve reception performance and parallel imaging, the number of array elements must be increased with a corresponding decrease in their size. With a large number of small interacting antennas, decoupling is one of the most challenging aspects in the design and construction of transceiver arrays. Previously described decoupling techniques using geometric overlap, inductive or capacitive decoupling have focused on the elimination of the reactance of the mutual impedance only, which can limit the obtainable decoupling to -10 dB as a result of residual mutual resistance. A novel resonant inductive decoupling (RID) method, which allows compensation for both reactive and resistive components of the mutual impedance between the adjacent surface coils, has been developed and verified experimentally. This method provides an easy way to adjust the decoupling remotely by changing the resonance frequency of the RID circuit through the adjustment of a variable capacitor. As an example, a single-row (1 × 16) 7-T transceiver head array of n = 16 small overlapped surface coils using RID decoupling between adjacent coils was built. In combination with overlapped coils, the RID technique achieved better than -24 dB of decoupling for all adjacent coils.
Copyright © 2013 John Wiley & Sons, Ltd.

Entities:  

Keywords:  RF head coil; array decoupling; high-field MRI; mutual resistance; transceiver arrays

Mesh:

Year:  2013        PMID: 23775840      PMCID: PMC3800502          DOI: 10.1002/nbm.2989

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  19 in total

1.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

2.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

3.  ICE decoupling technique for RF coil array designs.

Authors:  Ye Li; Zhentian Xie; Yong Pang; Daniel Vigneron; Xiaoliang Zhang
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  Radiative losses of a birdcage resonator.

Authors:  M D Harpen
Journal:  Magn Reson Med       Date:  1993-05       Impact factor: 4.668

5.  Size-optimized 32-channel brain arrays for 3 T pediatric imaging.

Authors:  Boris Keil; Vijay Alagappan; Azma Mareyam; Jennifer A McNab; Kyoko Fujimoto; Veneta Tountcheva; Christina Triantafyllou; Daniel D Dilks; Nancy Kanwisher; Weili Lin; P Ellen Grant; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

6.  Quantitative spectroscopic imaging of the human brain.

Authors:  J W Pan; D B Twieg; H P Hetherington
Journal:  Magn Reson Med       Date:  1998-09       Impact factor: 4.668

7.  Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

Authors:  Nikolai I Avdievich; Jullie W Pan; Hoby P Hetherington
Journal:  NMR Biomed       Date:  2013-06-18       Impact factor: 4.044

8.  Shielded microstrip array for 7T human MR imaging.

Authors:  Bing Wu; Chunsheng Wang; Douglas A C Kelley; Duan Xu; Daniel B Vigneron; Sarah J Nelson; Xiaoliang Zhang
Journal:  IEEE Trans Med Imaging       Date:  2009-10-09       Impact factor: 10.048

9.  An eight-channel phased array RF coil for spine MR imaging at 7 T.

Authors:  Oliver Kraff; Andreas K Bitz; Stefan Kruszona; Stephan Orzada; Lena C Schaefer; Jens M Theysohn; Stefan Maderwald; Mark E Ladd; Harald H Quick
Journal:  Invest Radiol       Date:  2009-11       Impact factor: 6.016

10.  Transceiver-Phased Arrays for Human Brain Studies at 7 T.

Authors:  Nikolai I Avdievich
Journal:  Appl Magn Reson       Date:  2011-12       Impact factor: 0.831

View more
  11 in total

1.  Parallel imaging performance investigation of an 8-channel common-mode differential-mode (CMDM) planar array for 7T MRI.

Authors:  Xiaoqing Hu; Xiao Chen; Xin Liu; Hairong Zheng; Ye Li; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

2.  A highly decoupled transmit-receive array design with triangular elements at 7T.

Authors:  Gang Chen; Bei Zhang; Martijn A Cloos; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2018-03-23       Impact factor: 4.668

3.  New resonator geometries for ICE decoupling of loop arrays.

Authors:  Xinqiang Yan; John C Gore; William A Grissom
Journal:  J Magn Reson       Date:  2017-02-16       Impact factor: 2.229

4.  Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

Authors:  Nikolai I Avdievich; Jullie W Pan; Hoby P Hetherington
Journal:  NMR Biomed       Date:  2013-06-18       Impact factor: 4.044

5.  Conductive Thread-Based Stretchable and Flexible Radiofrequency Coils for Magnetic Resonance Imaging.

Authors:  Jana M Vincent; Joseph V Rispoli
Journal:  IEEE Trans Biomed Eng       Date:  2019-11-28       Impact factor: 4.538

6.  Stitching Stretchable Radiofrequency Coils for MRI: A Conductive Thread and Athletic Fabric Approach.

Authors:  Jana M Vincent; Joseph V Rispoli
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2019-07

7.  Electromagnetic simulation of a 16-channel head transceiver at 7 T using circuit-spatial optimization.

Authors:  Xin Li; Jullie W Pan; Nikolai I Avdievich; Hoby P Hetherington; Joseph V Rispoli
Journal:  Magn Reson Med       Date:  2021-02-03       Impact factor: 3.737

8.  Modular transmit/receive arrays using very-high permittivity dielectric resonator antennas.

Authors:  Thomas P A O'Reilly; Thomas Ruytenberg; Andrew G Webb
Journal:  Magn Reson Med       Date:  2017-06-20       Impact factor: 4.668

9.  Self-decoupled radiofrequency coils for magnetic resonance imaging.

Authors:  Xinqiang Yan; John C Gore; William A Grissom
Journal:  Nat Commun       Date:  2018-08-28       Impact factor: 14.919

10.  Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI.

Authors:  Thomas Ruytenberg; Andrew Webb; Irena Zivkovic
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.