Literature DB >> 28698108

Imaging at ultrahigh magnetic fields: History, challenges, and solutions.

Kamil Uğurbil1.   

Abstract

Following early efforts in applying nuclear magnetic resonance (NMR) spectroscopy to study biological processes in intact systems, and particularly since the introduction of 4 T human scanners circa 1990, rapid progress was made in imaging and spectroscopy studies of humans at 4 T and animal models at 9.4 T, leading to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has provided numerous technological solutions to challenges posed at these ultrahigh fields, and demonstrated the existence of significant advantages in signal-to-noise ratio and biological information content. Primary difference from lower fields is the deviation from the near field regime at the radiofrequencies (RF) corresponding to hydrogen resonance conditions. At such ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image non-uniformities for a given sample-coil configuration because of destructive and constructive interferences. These non-uniformities were initially considered detrimental to progress of imaging at high field strengths. However, they are advantageous for parallel imaging in signal reception and transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies and improvements in instrumentation and imaging methods, today ultrahigh fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28698108      PMCID: PMC5758441          DOI: 10.1016/j.neuroimage.2017.07.007

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  245 in total

1.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

3.  Computation of electromagnetic fields for high-frequency magnetic resonance imaging applications.

Authors:  J M Jin; J Chen; W C Chew; H Gan; R L Magin; P J Dimbylow
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

4.  In vivo 1H NMR spectroscopy of the human brain at 9.4 T: initial results.

Authors:  Dinesh Kumar Deelchand; Pierre-François Van de Moortele; Gregor Adriany; Isabelle Iltis; Peter Andersen; John P Strupp; J Thomas Vaughan; Kâmil Uğurbil; Pierre-Gilles Henry
Journal:  J Magn Reson       Date:  2010-06-10       Impact factor: 2.229

5.  NMR imaging/spectroscopy system to study both anatomy and metabolism.

Authors:  P A Bottomley; H R Hart; W A Edelstein; J F Schenck; L S Smith; W M Leue; O M Mueller; R W Redington
Journal:  Lancet       Date:  1983-07-30       Impact factor: 79.321

6.  Toward imaging the body at 10.5 tesla.

Authors:  M Arcan Ertürk; Xiaoping Wu; Yiğitcan Eryaman; Pierre-François Van de Moortele; Edward J Auerbach; Russell L Lagore; Lance DelaBarre; J Thomas Vaughan; Kâmil Uğurbil; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2016-10-21       Impact factor: 4.668

7.  Design of parallel transmission pulses for simultaneous multislice with explicit control for peak power and local specific absorption rate.

Authors:  Bastien Guérin; Kawin Setsompop; Huihui Ye; Benedikt A Poser; Andrew V Stenger; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-06-17       Impact factor: 4.668

8.  Transmural metabolite distribution in regional myocardial ischemia as studied with 31P NMR.

Authors:  P M Robitaille; B Lew; H Merkle; E Sublett; P Lindstrom; A H From; M Garwood; R J Bache; K Uğurbil
Journal:  Magn Reson Med       Date:  1989-04       Impact factor: 4.668

9.  Phosphorus nuclear magnetic resonance study of the rat kidney in vivo.

Authors:  R S Balaban; D G Gadian; G K Radda
Journal:  Kidney Int       Date:  1981-11       Impact factor: 10.612

10.  Encoding of natural sounds at multiple spectral and temporal resolutions in the human auditory cortex.

Authors:  Roberta Santoro; Michelle Moerel; Federico De Martino; Rainer Goebel; Kamil Ugurbil; Essa Yacoub; Elia Formisano
Journal:  PLoS Comput Biol       Date:  2014-01-02       Impact factor: 4.475

View more
  35 in total

1.  Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array.

Authors:  Kamil Uğurbil; Edward Auerbach; Steen Moeller; Andrea Grant; Xiaoping Wu; Pierre-Francois Van de Moortele; Cheryl Olman; Lance DelaBarre; Scott Schillak; Jerahmie Radder; Russell Lagore; Gregor Adriany
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

Review 2.  RF pulse methods for use with surface coils: Frequency-modulated pulses and parallel transmission.

Authors:  Michael Garwood; Kamil Uğurbil
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

3.  Evaluation of a 16-channel transceiver loop + dipole antenna array for human head imaging at 10.5 tesla.

Authors:  Myung Kyun Woo; Lance DelaBarre; Byeong-Yeul Lee; Matt Waks; Russell Luke Lagore; Jerahmie Radder; Yigitcan Eryaman; Kamil Ugurbil; Gregor Adriany
Journal:  IEEE Access       Date:  2020-11-06       Impact factor: 3.367

4.  Human Connectome Project-style resting-state functional MRI at 7 Tesla using radiofrequency parallel transmission.

Authors:  Xiaoping Wu; Edward J Auerbach; An T Vu; Steen Moeller; Pierre-François Van de Moortele; Essa Yacoub; Kâmil Uğurbil
Journal:  Neuroimage       Date:  2018-09-17       Impact factor: 6.556

5.  Real-time assessment of potential peak local specific absorption rate value without phase monitoring: Trigonometric maximization method for worst-case local specific absorption rate determination.

Authors:  Ettore Flavio Meliadò; Alessandro Sbrizzi; Cornelis A T van den Berg; Peter R Luijten; Alexander J E Raaijmakers
Journal:  Magn Reson Med       Date:  2020-12-22       Impact factor: 4.668

6.  10.5 T MRI static field effects on human cognitive, vestibular, and physiological function.

Authors:  Andrea Grant; Gregory J Metzger; Pierre-François Van de Moortele; Gregor Adriany; Cheryl Olman; Lin Zhang; Joseph Koopermeiners; Yiğitcan Eryaman; Margaret Koeritzer; Meredith E Adams; Thomas R Henry; Kamil Uğurbil
Journal:  Magn Reson Imaging       Date:  2020-08-18       Impact factor: 2.546

7.  First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.

Authors:  Xiaoxuan He; M Arcan Ertürk; Andrea Grant; Xiaoping Wu; Russell L Lagore; Lance DelaBarre; Yiğitcan Eryaman; Gregor Adriany; Eddie J Auerbach; Pierre-François Van de Moortele; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2019-12-17       Impact factor: 4.668

Review 8.  Parallel Transmission for Ultrahigh Field MRI.

Authors:  Cem M Deniz
Journal:  Top Magn Reson Imaging       Date:  2019-06

9.  Specific absorption rate implications of within-scan patient head motion for ultra-high field MRI.

Authors:  Emre Kopanoglu; Cem M Deniz; M Arcan Erturk; Richard G Wise
Journal:  Magn Reson Med       Date:  2020-04-17       Impact factor: 4.668

10.  High-resolution whole-brain diffusion MRI at 7T using radiofrequency parallel transmission.

Authors:  Xiaoping Wu; Edward J Auerbach; An T Vu; Steen Moeller; Christophe Lenglet; Sebastian Schmitter; Pierre-François Van de Moortele; Essa Yacoub; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2018-03-30       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.