Literature DB >> 20510201

Anatomic and pathologic variability during radiotherapy for a hybrid active breath-hold gating technique.

Carri K Glide-Hurst1, Ellen Gopan, Geoffrey D Hugo.   

Abstract

PURPOSE: To evaluate intra- and interfraction variability of tumor and lung volume and position using a hybrid active breath-hold gating technique. METHODS AND MATERIALS: A total of 159 repeat normal inspiration active breath-hold CTs were acquired weekly during radiotherapy for 9 lung cancer patients (12-21 scans per patient). A physician delineated the gross tumor volume (GTV), lungs, and spinal cord on the first breath-hold CT, and contours were propagated semiautomatically. Intra- and interfraction variability of tumor and lung position and volume were evaluated. Tumor centroid and border variability were quantified.
RESULTS: On average, intrafraction variability of lung and GTV centroid position was <2.0 mm. Interfraction population variability was 3.6-6.7 mm (systematic) and 3.1-3.9 mm (random) for the GTV centroid and 1.0-3.3 mm (systematic) and 1.5-2.6 mm (random) for the lungs. Tumor volume regressed 44.6% +/- 23.2%. Gross tumor volume border variability was patient specific and demonstrated anisotropic shape change in some subjects. Interfraction GTV positional variability was associated with tumor volume regression and contralateral lung volume (p < 0.05). Inter-breath-hold reproducibility was unaffected by time point in the treatment course (p > 0.1). Increases in free-breathing tidal volume were associated with increases in breath-hold ipsilateral lung volume (p < 0.05).
CONCLUSIONS: The breath-hold technique was reproducible within 2 mm during each fraction. Interfraction variability of GTV position and shape was substantial because of tumor volume and breath-hold lung volume change during therapy. These results support the feasibility of a hybrid breath-hold gating technique and suggest that online image guidance would be beneficial. (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20510201      PMCID: PMC2956181          DOI: 10.1016/j.ijrobp.2009.09.080

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  22 in total

1.  The use of active breathing control (ABC) to reduce margin for breathing motion.

Authors:  J W Wong; M B Sharpe; D A Jaffray; V R Kini; J M Robertson; J S Stromberg; A A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-01       Impact factor: 7.038

2.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.

Authors:  M van Herk; P Remeijer; C Rasch; J V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

3.  Quality and accuracy of cone beam computed tomography gated by active breathing control.

Authors:  Bria P Thompson; Geoffrey D Hugo
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer.

Authors:  David Sarrut; Vlad Boldea; Myriam Ayadi; Jean-Noël Badel; Chantal Ginestet; Sébastien Clippe; Christian Carrie
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

5.  The effectiveness of breath-holding to stabilize lung and pancreas tumors during radiosurgery.

Authors:  Martin J Murphy; David Martin; Richard Whyte; Jenny Hai; Cihat Ozhasoglu; Quynh-Thu Le
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-06-01       Impact factor: 7.038

6.  Effect of ABVD chemotherapy with and without mantle or mediastinal irradiation on pulmonary function and symptoms in early-stage Hodgkin's disease.

Authors:  A Hirsch; N Vander Els; D J Straus; E G Gomez; D Leung; C S Portlock; J Yahalom
Journal:  J Clin Oncol       Date:  1996-04       Impact factor: 44.544

7.  Three-dimensional evaluation of intra- and interfraction immobilization of lung and chest wall using active breathing control: a reproducibility study with breast cancer patients.

Authors:  Vincent M Remouchamps; Nicola Letts; Di Yan; Frank A Vicini; Michel Moreau; Julie A Zielinski; Jian Liang; Larry L Kestin; Alvaro A Martinez; John W Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-11-15       Impact factor: 7.038

8.  Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer.

Authors:  Sara C Erridge; Yvette Seppenwoolde; Sara H Muller; Marcel van Herk; Katrien De Jaeger; José S A Belderbos; Liesbeth J Boersma; Joos V Lebesque
Journal:  Radiother Oncol       Date:  2003-01       Impact factor: 6.280

9.  Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC).

Authors:  Patrick C F Cheung; Katharina E Sixel; Romeo Tirona; Yee C Ung
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-12-01       Impact factor: 7.038

10.  Measurement of lung tumor motion using respiration-correlated CT.

Authors:  Gig S Mageras; Alex Pevsner; Ellen D Yorke; Kenneth E Rosenzweig; Eric C Ford; Agung Hertanto; Steven M Larson; D Michael Lovelock; Yusuf E Erdi; Sadek A Nehmeh; John L Humm; C Clifton Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-01       Impact factor: 7.038

View more
  15 in total

1.  Localization accuracy of the clinical target volume during image-guided radiotherapy of lung cancer.

Authors:  Geoffrey D Hugo; Elisabeth Weiss; Ahmed Badawi; Matthew Orton
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-27       Impact factor: 7.038

2.  Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy.

Authors:  Scott P Robertson; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

Review 3.  Improving radiotherapy planning, delivery accuracy, and normal tissue sparing using cutting edge technologies.

Authors:  Carri K Glide-Hurst; Indrin J Chetty
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

4.  Practical Clinical Workflows for Online and Offline Adaptive Radiation Therapy.

Authors:  Olga L Green; Lauren E Henke; Geoffrey D Hugo
Journal:  Semin Radiat Oncol       Date:  2019-07       Impact factor: 5.934

5.  Deep inspiration breath-hold radiotherapy for lung cancer: impact on image quality and registration uncertainty in cone beam CT image guidance.

Authors:  Mirjana Josipovic; Gitte F Persson; Jens P Bangsgaard; Lena Specht; Marianne C Aznar
Journal:  Br J Radiol       Date:  2016-10-26       Impact factor: 3.039

6.  Tumor, lymph node, and lymph node-to-tumor displacements over a radiotherapy series: analysis of interfraction and intrafraction variations using active breathing control (ABC) in lung cancer.

Authors:  Elisabeth Weiss; Scott P Robertson; Nitai Mukhopadhyay; Geoffrey D Hugo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-12-22       Impact factor: 7.038

7.  Deformable mesh registration for the validation of automatic target localization algorithms.

Authors:  Scott Robertson; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

8.  Optimizing principal component models for representing interfraction variation in lung cancer radiotherapy.

Authors:  Ahmed M Badawi; Elisabeth Weiss; William C Sleeman; Chenyu Yan; Geoffrey D Hugo
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

9.  Interfraction displacement of primary tumor and involved lymph nodes relative to anatomic landmarks in image guided radiation therapy of locally advanced lung cancer.

Authors:  Nuzhat Jan; Salim Balik; Geoffrey D Hugo; Nitai Mukhopadhyay; Elisabeth Weiss
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-11-13       Impact factor: 7.038

10.  A block matching-based registration algorithm for localization of locally advanced lung tumors.

Authors:  Scott P Robertson; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.