Literature DB >> 15667982

Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer.

David Sarrut1, Vlad Boldea, Myriam Ayadi, Jean-Noël Badel, Chantal Ginestet, Sébastien Clippe, Christian Carrie.   

Abstract

PURPOSE: To study the interfraction reproducibility of breath-holding using active breath control (ABC), and to develop computerized tools to evaluate three-dimensional (3D) intrathoracic motion in each patient. METHODS AND MATERIALS: Since June 2002, 11 patients with non-small-cell lung cancer enrolled in a Phase II trial have undergone four CT scans: one during free-breathing (reference) and three using ABC. Patients left the room between breath-hold scans. The patient's breath was held at the same predefined phase of the breathing cycle (about 70% of the vital capacity) using the ABC device, then patients received 3D-conformal radiotherapy. Automated computerized tools for breath-hold CT scans were developed to analyze lung and tumor interfraction residual motions with 3D nonrigid registration.
RESULTS: All patients but one were safely treated with ABC for 7 weeks. For 6 patients, the lung volume differences were <5%. The mean 3D displacement inside the lungs was between 2.3 mm (SD 1.4) and 4 mm (SD 3.3), and the gross tumor volume residual motion was 0.9 mm (SD 0.4) to 5.9 mm (SD 0.7). The residual motion was slightly greater in the inferior part of the lung than the superior. For 2 patients, we detected volume changes >300 cm(3) and displacements >10 mm, probably owing to atelectasia and emphysema. One patient was excluded, and two others had incomplete data sets.
CONCLUSION: Breath-holding with ABC was effective in 6 patients, and discrepancies were clinically accountable in 2. The proposed 3D nonrigid registration method allows for personalized evaluation of breath-holding reproducibility with ABC. It will be used to adapt the patient-specific internal margins.

Entities:  

Mesh:

Year:  2005        PMID: 15667982     DOI: 10.1016/j.ijrobp.2004.08.007

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  10 in total

1.  Pulmonary CT image registration and warping for tracking tissue deformation during the respiratory cycle through 3D consistent image registration.

Authors:  Baojun Li; Gary E Christensen; Eric A Hoffman; Geoffrey McLennan; Joseph M Reinhardt
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

2.  4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

Authors:  Yugang Min; John Neylon; Amish Shah; Sanford Meeks; Percy Lee; Patrick Kupelian; Anand P Santhanam
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-01-14       Impact factor: 2.924

3.  Tumor, lymph node, and lymph node-to-tumor displacements over a radiotherapy series: analysis of interfraction and intrafraction variations using active breathing control (ABC) in lung cancer.

Authors:  Elisabeth Weiss; Scott P Robertson; Nitai Mukhopadhyay; Geoffrey D Hugo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-12-22       Impact factor: 7.038

4.  Application of a deformable registration technique to investigate breath-hold reproducibility.

Authors:  Nobuyoshi Fukumitsu; Yasutaka Hayashi
Journal:  Jpn J Radiol       Date:  2014-11-08       Impact factor: 2.374

5.  Anatomic and pathologic variability during radiotherapy for a hybrid active breath-hold gating technique.

Authors:  Carri K Glide-Hurst; Ellen Gopan; Geoffrey D Hugo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-07-01       Impact factor: 7.038

6.  Determination of reproducibility of end-exhaled breath-holding in stereotactic body radiation therapy.

Authors:  Motoharu Sasaki; Hitoshi Ikushima; Kanako Sakuragawa; Michihiro Yokoishi; Akira Tsuzuki; Wataru Sugimoto
Journal:  J Radiat Res       Date:  2020-11-16       Impact factor: 2.724

7.  Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control.

Authors:  Yali Shen; Hong Zhang; Jin Wang; Renming Zhong; Xiaoqing Jiang; Qinfeng Xu; Xin Wang; Sen Bai; Feng Xu
Journal:  Radiat Oncol       Date:  2010-02-27       Impact factor: 3.481

8.  Estimation of pulmonary motion in healthy subjects and patients with intrathoracic tumors using 3D-dynamic MRI: initial results.

Authors:  Christian Plathow; Max Schoebinger; Felix Herth; Siegfried Tuengerthal; Heinz-Peter Meinzer; Hans-Ulrich Kauczor
Journal:  Korean J Radiol       Date:  2009 Nov-Dec       Impact factor: 3.500

9.  First MRI application of an active breathing coordinator.

Authors:  E Kaza; R Symonds-Tayler; D J Collins; F McDonald; H A McNair; E Scurr; D-M Koh; M O Leach
Journal:  Phys Med Biol       Date:  2015-01-29       Impact factor: 3.609

Review 10.  [Advances of precise radiotherapy for lung cancer].

Authors:  Xin Wang; Feng Xu; Yuquan Wei
Journal:  Zhongguo Fei Ai Za Zhi       Date:  2011-11
  10 in total