Literature DB >> 24694124

A block matching-based registration algorithm for localization of locally advanced lung tumors.

Scott P Robertson1, Elisabeth Weiss1, Geoffrey D Hugo1.   

Abstract

PURPOSE: To implement and evaluate a block matching-based registration (BMR) algorithm for locally advanced lung tumor localization during image-guided radiotherapy.
METHODS: Small (1 cm(3)), nonoverlapping image subvolumes ("blocks") were automatically identified on the planning image to cover the tumor surface using a measure of the local intensity gradient. Blocks were independently and automatically registered to the on-treatment image using a rigid transform. To improve speed and robustness, registrations were performed iteratively from coarse to fine image resolution. At each resolution, all block displacements having a near-maximum similarity score were stored. From this list, a single displacement vector for each block was iteratively selected which maximized the consistency of displacement vectors across immediately neighboring blocks. These selected displacements were regularized using a median filter before proceeding to registrations at finer image resolutions. After evaluating all image resolutions, the global rigid transform of the on-treatment image was computed using a Procrustes analysis, providing the couch shift for patient setup correction. This algorithm was evaluated for 18 locally advanced lung cancer patients, each with 4-7 weekly on-treatment computed tomography scans having physician-delineated gross tumor volumes. Volume overlap (VO) and border displacement errors (BDE) were calculated relative to the nominal physician-identified targets to establish residual error after registration.
RESULTS: Implementation of multiresolution registration improved block matching accuracy by 39% compared to registration using only the full resolution images. By also considering multiple potential displacements per block, initial errors were reduced by 65%. Using the final implementation of the BMR algorithm, VO was significantly improved from 77% ± 21% (range: 0%-100%) in the initial bony alignment to 91% ± 8% (range: 56%-100%;p < 0.001). Left-right, anterior-posterior, and superior-inferior systematic BDE were 3.2, 2.4, and 4.4 mm, respectively, with random BDE of 2.4, 2.1, and 2.7 mm. Margins required to include both localization and delineation uncertainties ranged from 5.0 to 11.7 mm, an average of 40% less than required for bony alignment.
CONCLUSIONS: BMR is a promising approach for automatic lung tumor localization. Further evaluation is warranted to assess the accuracy and robustness of BMR against other potential localization strategies.
© 2014 American Association of Physicists in Medicine.

Entities:  

Mesh:

Year:  2014        PMID: 24694124      PMCID: PMC3978354          DOI: 10.1118/1.4867860

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  27 in total

1.  Non-rigid image registration using a median-filtered coarse-to-fine displacement field and a symmetric correlation ratio.

Authors:  Y H Lau; M Braun; B F Hutton
Journal:  Phys Med Biol       Date:  2001-04       Impact factor: 3.609

2.  Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry.

Authors:  Gary E Christensen; Joo Hyun Song; Wei Lu; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

3.  Model-independent, multimodality deformable image registration by local matching of anatomical features and minimization of elastic energy.

Authors:  Matthias Söhn; Mattias Birkner; Yuwei Chi; Jian Wang; Yan Di; Bernhard Berger; Markus Alber
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

4.  Tumor volume changes on serial imaging with megavoltage CT for non-small-cell lung cancer during intensity-modulated radiotherapy: how reliable, consistent, and meaningful is the effect?

Authors:  Malika L Siker; Wolfgang A Tomé; Minesh P Mehta
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-07-12       Impact factor: 7.038

5.  An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy.

Authors:  U Malsch; C Thieke; P E Huber; R Bendl
Journal:  Phys Med Biol       Date:  2006-09-08       Impact factor: 3.609

6.  Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position.

Authors:  Thomas G Purdie; Jean-Pierre Bissonnette; Kevin Franks; Andrea Bezjak; David Payne; Fanny Sie; Michael B Sharpe; David A Jaffray
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-02-27       Impact factor: 7.038

7.  Clinicopathologic analysis of microscopic extension in lung adenocarcinoma: defining clinical target volume for radiotherapy.

Authors:  Inga S Grills; Dwight L Fitch; Neal S Goldstein; Di Yan; Gary W Chmielewski; Robert J Welsh; Larry L Kestin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-06-14       Impact factor: 7.038

8.  Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device.

Authors:  Gerben R Borst; Jan-Jakob Sonke; Anja Betgen; Peter Remeijer; Marcel van Herk; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-29       Impact factor: 7.038

Review 9.  Different styles of image-guided radiotherapy.

Authors:  Marcel van Herk
Journal:  Semin Radiat Oncol       Date:  2007-10       Impact factor: 5.934

10.  Target repositional accuracy and PTV margin verification using three-dimensional cone-beam computed tomography (CBCT) in stereotactic body radiotherapy (SBRT) of lung cancers.

Authors:  Lu Wang; Steven Feigenberg; Jiajian Fan; Lihui Jin; Aruna Turaka; Lili Chen; C-M Charlie Ma
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

View more
  2 in total

1.  Biomechanical deformable image registration of longitudinal lung CT images using vessel information.

Authors:  Guillaume Cazoulat; Dawn Owen; Martha M Matuszak; James M Balter; Kristy K Brock
Journal:  Phys Med Biol       Date:  2016-06-08       Impact factor: 3.609

2.  A longitudinal four-dimensional computed tomography and cone beam computed tomography dataset for image-guided radiation therapy research in lung cancer.

Authors:  Geoffrey D Hugo; Elisabeth Weiss; William C Sleeman; Salim Balik; Paul J Keall; Jun Lu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2017-02-02       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.