Literature DB >> 22225303

Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy.

Scott P Robertson1, Elisabeth Weiss, Geoffrey D Hugo.   

Abstract

PURPOSE: To evaluate localization accuracy resulting from rigid registration of locally-advanced lung cancer targets using fully automatic and semi-automatic protocols for image-guided radiation therapy.
METHODS: Seventeen lung cancer patients, fourteen also presenting with involved lymph nodes, received computed tomography (CT) scans once per week throughout treatment under active breathing control. A physician contoured both lung and lymph node targets for all weekly scans. Various automatic and semi-automatic rigid registration techniques were then performed for both individual and simultaneous alignments of the primary gross tumor volume (GTV(P)) and involved lymph nodes (GTV(LN)) to simulate the localization process in image-guided radiation therapy. Techniques included "standard" (direct registration of weekly images to a planning CT), "seeded" (manual prealignment of targets to guide standard registration), "transitive-based" (alignment of pretreatment and planning CTs through one or more intermediate images), and "rereferenced" (designation of a new reference image for registration). Localization error (LE) was assessed as the residual centroid and border distances between targets from planning and weekly CTs after registration.
RESULTS: Initial bony alignment resulted in centroid LE of 7.3 ± 5.4 mm and 5.4 ± 3.4 mm for the GTV(P) and GTV(LN), respectively. Compared to bony alignment, transitive-based and seeded registrations significantly reduced GTV(P) centroid LE to 4.7 ± 3.7 mm (p = 0.011) and 4.3 ± 2.5 mm (p < 1 × 10(-3)), respectively, but the smallest GTV(P) LE of 2.4 ± 2.1 mm was provided by rereferenced registration (p < 1 × 10(-6)). Standard registration significantly reduced GTV(LN) centroid LE to 3.2 ± 2.5 mm (p < 1 × 10(-3)) compared to bony alignment, with little additional gain offered by the other registration techniques. For simultaneous target alignment, centroid LE as low as 3.9 ± 2.7 mm and 3.8 ± 2.3 mm were achieved for the GTV(P) and GTV(LN), respectively, using rereferenced registration.
CONCLUSIONS: Target shape, volume, and configuration changes during radiation therapy limited the accuracy of standard rigid registration for image-guided localization in locally-advanced lung cancer. Significant error reductions were possible using other rigid registration techniques, with LE approaching the lower limit imposed by interfraction target variability throughout treatment.

Entities:  

Mesh:

Year:  2012        PMID: 22225303      PMCID: PMC3259614          DOI: 10.1118/1.3671929

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  40 in total

1.  Magnitude and clinical relevance of translational and rotational patient setup errors: a cone-beam CT study.

Authors:  Matthias Guckenberger; Juergen Meyer; Dirk Vordermark; Kurt Baier; Juergen Wilbert; Michael Flentje
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-07-01       Impact factor: 7.038

Review 2.  Advances in image-guided radiation therapy.

Authors:  Laura A Dawson; David A Jaffray
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

3.  Tumor volume changes on serial imaging with megavoltage CT for non-small-cell lung cancer during intensity-modulated radiotherapy: how reliable, consistent, and meaningful is the effect?

Authors:  Malika L Siker; Wolfgang A Tomé; Minesh P Mehta
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-07-12       Impact factor: 7.038

Review 4.  Adaptive radiotherapy for lung cancer.

Authors:  Jan-Jakob Sonke; José Belderbos
Journal:  Semin Radiat Oncol       Date:  2010-04       Impact factor: 5.934

5.  Assessment of gross tumor volume regression and motion changes during radiotherapy for non-small-cell lung cancer as measured by four-dimensional computed tomography.

Authors:  Keith R Britton; George Starkschall; Susan L Tucker; Tinsu Pan; Christopher Nelson; Joe Y Chang; James D Cox; Radhe Mohan; Ritsuko Komaki
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-26       Impact factor: 7.038

6.  Tumor regression and positional changes in non-small cell lung cancer during radical radiotherapy.

Authors:  Gerald Lim; Andrea Bezjak; Jane Higgins; Doug Moseley; Andrew J Hope; Alex Sun; John B C Cho; Anthony M Brade; Clement Ma; Jean-Pierre Bissonnette
Journal:  J Thorac Oncol       Date:  2011-03       Impact factor: 15.609

7.  Evolution of surface-based deformable image registration for adaptive radiotherapy of non-small cell lung cancer (NSCLC).

Authors:  Matthias Guckenberger; Kurt Baier; Anne Richter; Juergen Wilbert; Michael Flentje
Journal:  Radiat Oncol       Date:  2009-12-21       Impact factor: 3.481

8.  Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy.

Authors:  Inga S Grills; Geoffrey Hugo; Larry L Kestin; Ana Paula Galerani; K Kenneth Chao; Jennifer Wloch; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-29       Impact factor: 7.038

9.  An evaluation of two internal surrogates for determining the three-dimensional position of peripheral lung tumors.

Authors:  Femke O B Spoelstra; John R van Sörnsen de Koste; Andrew Vincent; Johan P Cuijpers; Ben J Slotman; Suresh Senan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-26       Impact factor: 7.038

Review 10.  Image-guided radiation therapy for non-small cell lung cancer.

Authors:  Joe Y Chang; Lei Dong; Helen Liu; George Starkschall; Peter Balter; Radhe Mohan; Zhongxing Liao; James D Cox; Ritsuko Komaki
Journal:  J Thorac Oncol       Date:  2008-02       Impact factor: 15.609

View more
  4 in total

1.  Deformable mesh registration for the validation of automatic target localization algorithms.

Authors:  Scott Robertson; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

2.  Imaging study of pseudo-CT images of superposed ultrasound deformation fields acquired in radiotherapy based on step-by-step local registration.

Authors:  Hongfei Sun; Tao Lin; Kai Xie; Liugang Gao; Jianfeng Sui; Xinye Ni
Journal:  Med Biol Eng Comput       Date:  2018-10-15       Impact factor: 2.602

3.  A block matching-based registration algorithm for localization of locally advanced lung tumors.

Authors:  Scott P Robertson; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

4.  Effect of variations in atelectasis on tumor displacement during radiation therapy for locally advanced lung cancer.

Authors:  Nathan Tennyson; Elisabeth Weiss; William Sleeman; Mihaela Rosu; Nuzhat Jan; Geoffrey D Hugo
Journal:  Adv Radiat Oncol       Date:  2016-12-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.