Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Jonathan Mutimer1, Peter A Devane, Kathryn Adams, J Geoffrey Horne.   

Abstract

BACKGROUND: Although hip arthroplasty reliably relieves pain and improves function, problems have arisen with wear and osteolysis. Highly crosslinked polyethylene has been developed to address this problem although at present there is limited clinical evidence it does so longer term. QUESTIONS/PURPOSES: We compared the in vivo wear of standard versus highly crosslinked polyethylene (HXLP) in primary total hip arthroplasty at a minimum of 5-year followup.
METHODS: We enrolled 122 patients in a prospective, double-blinded, randomized trial and followed them annually to assess their progress. Annual radiographs were analyzed using previously validated edge detection software to assess for two-dimensional, three-dimensional, and volumetric wear. The mean follow up was 5.5 years (range, 4.1 to 7 years).
RESULTS: The two-dimensional wear measurements for HXLP showed lower wear compared to the conventional group (0.05 mm/year versus 0.26 mm/year, respectively). Three-dimensional and volumetric wear were similarly lower in the HXLP group.
CONCLUSIONS: Highly crosslinked polyethylene undergoes substantially less wear than conventional polyethylene at medium term. The effect of hip arthroplasty longevity will need to be assessed with longer-term studies, but this may lead to a decreased need for revision as a result of less wear and osteolysis.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20458640      PMCID: PMC2974871          DOI: 10.1007/s11999-010-1379-4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

Review 1.  Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature.

Authors:  P C Oparaugo; I C Clarke; H Malchau; P Herberts
Journal:  Acta Orthop Scand       Date:  2001-02

2.  Assessment of polyethylene wear in total hip replacement.

Authors:  P A Devane; J G Horne
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

3.  Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty.

Authors:  Andrew J Hui; Richard W McCalden; John M Martell; Steven J MacDonald; Robert B Bourne; Cecil H Rorabeck
Journal:  J Bone Joint Surg Am       Date:  2003-03       Impact factor: 5.284

4.  Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement.

Authors:  W J Maloney; J O Galante; M Anderson; V Goldberg; W H Harris; J Jacobs; M Kraay; P Lachiewicz; H E Rubash; S Schutzer; S T Woolson
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

5.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

6.  Charnley total hip arthroplasty with cement. Fifteen-year results.

Authors:  B F Kavanagh; M A Dewitz; D M Ilstrup; R N Stauffer; M B Coventry
Journal:  J Bone Joint Surg Am       Date:  1989-12       Impact factor: 5.284

7.  Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Christopher Verioti; Kace A Ezzet; Steven N Copp; Richard H Walker; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

Review 8.  Bearing surface options for total hip replacement in young patients.

Authors:  Christian Heisel; Mauricio Silva; Thomas P Schmalzried
Journal:  Instr Course Lect       Date:  2004

9.  Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up.

Authors:  Karl F Orishimo; Alexandra M Claus; Christi J Sychterz; Charles A Engh
Journal:  J Bone Joint Surg Am       Date:  2003-06       Impact factor: 5.284

Review 10.  Alternative materials to improve total hip replacement tribology.

Authors:  Seppo Santavirta; Max Böhler; William H Harris; Yrjö T Konttinen; Reijo Lappalainen; Orhun Muratoglu; Claude Rieker; Martin Salzer
Journal:  Acta Orthop Scand       Date:  2003-08
View more
  26 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Second-generation annealed highly cross-linked polyethylene exhibits low wear.

Authors:  James A D'Antonio; William N Capello; Rama Ramakrishnan
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

3.  Short-term wear evaluation of thin acetabular liners on 36-mm femoral heads.

Authors:  Aaron J Johnson; LaQuawn Loving; Lizeth Herrera; Ronald E Delanois; Aiguo Wang; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

4.  Metal-on-conventional polyethylene total hip arthroplasty bearing surfaces have a higher risk of revision than metal-on-highly crosslinked polyethylene: results from a US registry.

Authors:  Elizabeth W Paxton; Maria C S Inacio; Robert S Namba; Rebecca Love; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

Review 5.  Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.

Authors:  Hugo C van der Veen; Hans-Peter W van Jonbergen; Rudolf W Poolman; Sjoerd K Bulstra; Jos J A M van Raay
Journal:  Int Orthop       Date:  2012-12-11       Impact factor: 3.075

6.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

7.  Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  George K Karidakis; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

8.  The influence of bearing surfaces on periprosthetic hip infections: analysis of thirty nine thousand, two hundred and six  cementless total hip arthroplasties.

Authors:  Barbara Bordini; Susanna Stea; Francesco Castagnini; Luca Busanelli; Federico Giardina; Aldo Toni
Journal:  Int Orthop       Date:  2018-08-11       Impact factor: 3.075

9.  Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?

Authors:  Julio J Jauregui; Qais Naziri; Todd P Pierce; Randa K Elmallah; Jeffrey J Cherian; Ronald E Delanois; Michael A Mont
Journal:  Int Orthop       Date:  2015-07-02       Impact factor: 3.075

10.  Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles.

Authors:  Yufei Yan; Hao Chen; Jianmin Feng; Kaizhe Chen; Kaidi Zhou; Weixiang Hong; Yi Wang; Zhihong Liu; Jiong Zhang; Qingming Yang; Lei Guo; Chuan He
Journal:  Int Orthop       Date:  2016-05-13       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.