Literature DB >> 11327409

Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature.

P C Oparaugo1, I C Clarke, H Malchau, P Herberts.   

Abstract

This survey focused on clinical reports of polyethylene wear and osteolysis in total hip replacements. With regard to documentation of clinical wear-rates, 57 publications were reduced to an analysis of 8 reports of THR series, including the incidence of osteolysis. A direct correlation was found among volumetric wear-rates, incidence of osteolysis and revision rates in THR concepts of the 1983-1987 era. As volumetric wear rate increased, the incidence of osteolysis and revision rates increased. With regard to our grading system for volumetric wear, with follow-up in the 4-15 year range, osteolysis was rare in group A (wear = 0-80 mm3/year), ranging from 6% to 31% in group B (wear 40-80 mm3/year) and from 21% to 100% in group C (wear > 140 mm3/year). With regard to cup design, the optimal low-wear group had mainly cemented polyethylene cups with 22 and 28 mm head sizes. The mid-wear group B had metal-backed cemented and uncemented cups, with 28 mm head size, and the high-risk group C had only uncemented, metal-backed cups, with the highest wear in the 32 mm head size. Less than 10 years of follow-up did not distinguish adequately between different designs of THR, except in a few cases which had early failures due to material or design deficiencies. Overall, the cemented all-polyethylene cup combined with the smaller ball head proved to be better.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11327409     DOI: 10.1080/000164701753606644

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  23 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  The prevalence of groin pain after metal-on-metal total hip arthroplasty and total hip resurfacing.

Authors:  Robert B Bartelt; Brandon J Yuan; Robert T Trousdale; Rafael J Sierra
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

3.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

Review 4.  A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty.

Authors:  Zongyou Mu; Jialiang Tian; Taixiang Wu; Jing Yang; Fuxing Pei
Journal:  Int Orthop       Date:  2009-01-29       Impact factor: 3.075

5.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

6.  The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.

Authors:  Siôn Glyn-Jones; Geraint E R Thomas; Patrick Garfjeld-Roberts; Roger Gundle; Adrian Taylor; Peter McLardy-Smith; David W Murray
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

7.  Analysis of the cytotoxicity of differentially sized titanium dioxide nanoparticles in murine MC3T3-E1 preosteoblasts.

Authors:  Yilin Zhang; Weiqiang Yu; Xinquan Jiang; Kaige Lv; Shengjun Sun; Fuqiang Zhang
Journal:  J Mater Sci Mater Med       Date:  2011-06-18       Impact factor: 3.896

8.  Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner.

Authors:  Min-Yook Kim; Young-Yool Chung; Ji-Hoon Park; Jung-Ho Lee
Journal:  Hip Pelvis       Date:  2015-12-30

9.  Can the volume of pelvic osteolysis be calculated without using computed tomography?

Authors:  Hiroshi Egawa; Cara C Powers; Sarah E Beykirch; Robert H Hopper; C Anderson Engh; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

10.  Periprosthetic osteolysis after total wrist arthroplasty.

Authors:  Michel E H Boeckstyns; Guillaume Herzberg
Journal:  J Wrist Surg       Date:  2014-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.