Charnley total hip arthroplasty with cement. Fifteen-year results.

B F Kavanagh1, M A Dewitz, D M Ilstrup, R N Stauffer, M B Coventry.   

Abstract

The results of the first 333 Charnley total hip arthroplasties that were performed with cement at the Mayo Clinic were reviewed a minimum of fifteen years postoperatively. Data were available for 166 of 170 hips of patients who were still alive. One hundred and thirty patients died, and thirty-seven hips were revised. At the time of this study, 80 per cent of the living patients had no pain, and 152 of the 160 hips remained much better than before the operation. Kaplan-Meier analysis of probable loosening of one or both components, on the basis of roentgenographic evidence, demonstrated a probability of loosening of 3 per cent incidence at one year after operation, 13 per cent at five years, 19 per cent at ten years, and 32 per cent at fifteen years. The probability of failure (that is, revision or symptomatic loosening) was 0.9 per cent at one year, 4.1 per cent at five years, 8.9 per cent at ten years, and 12.7 per cent at fifteen years. We did not identify a dramatic increase in the incidence of loosening or failure at any of the follow-up periods (one, five, ten, or fifteen years). With the Mayo Clinic clinical and roentgenographic system for scoring the hips, we found that ninety-seven hips had a good or excellent result; fifteen, a fair result; and thirteen, a poor result. (The scoring could not be completed for forty-one hips). The functional results deteriorated slightly over time.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2592389

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  12 in total

1.  Bone remodelling: should we cry Wolff?

Authors:  T C Lee; D Taylor
Journal:  Ir J Med Sci       Date:  1999 Apr-Jun       Impact factor: 1.568

2.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

3.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

4.  Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs.

Authors:  D Kneif; M Downing; G P Ashcroft; P Gibson; D Knight; W Ledingham; J Hutchison
Journal:  Int Orthop       Date:  2005-04-02       Impact factor: 3.075

Review 5.  Total hip arthroplasty.

Authors:  J S Siopack; H E Jergesen
Journal:  West J Med       Date:  1995-03

6.  Management of high-energy acetabular fractures in the elderly individuals: a current review.

Authors:  Brian W Hill; Julie A Switzer; Peter A Cole
Journal:  Geriatr Orthop Surg Rehabil       Date:  2012-09

7.  Improved results of primary total hip replacement.

Authors:  Bjørg-Tilde S Fevang; Stein A Lie; Leif I Havelin; Lars B Engesaeter; Ove Furnes
Journal:  Acta Orthop       Date:  2010-12       Impact factor: 3.717

8.  Classifications in Brief: The Dorr Classification of Femoral Bone.

Authors:  Jacob Wilkerson; Navin D Fernando
Journal:  Clin Orthop Relat Res       Date:  2020-05-06       Impact factor: 4.755

9.  Arterial embolism due to massive cement leakage during total hip arthroplasty revision.

Authors:  Yusuke Kazama; Yasuhiko Takegami; Yusuke Osawa; Kazuya Makida; Taisuke Seki
Journal:  Nagoya J Med Sci       Date:  2021-05       Impact factor: 1.131

10.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359