Literature DB >> 27178441

Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles.

Yufei Yan1,2, Hao Chen1,2, Jianmin Feng2, Kaizhe Chen1,2, Kaidi Zhou1,2, Weixiang Hong1,2, Yi Wang2, Zhihong Liu1,2, Jiong Zhang2, Qingming Yang1,2, Lei Guo3,4, Chuan He5,6.   

Abstract

PURPOSE: The aim of the present study was to investigate the long-term outcome and the wear characteristics of two distinct types of ultra-high molecular weight polyethylene (UHMWPE) liners in total hip arthroplasty (THA).
METHODS: We conducted a retrospective clinical study on patients which were treated with total hip arthroplasty using either Enduron polyethylene (Enduron PE) or Trilogy polyethylene (Trilogy PE) liners based on a minimum of ten year follow up data. Morphological analyses of wear particles from tissue samples, which were harvested during revision surgeries, were also performed.
RESULTS: A total of 79 THAs in the Enduron group and 55 THAs in the Trilogy group were available for analysis. Kaplan-Meier survival with revision for wear-related complications as the endpoint of the Enduron PE liners was lower than that of Trilogy PE liners at ten years (93.5 % and 100 %, P = 0.03). The Enduron group had higher mean linear wear rate than that of the Trilogy group (0.20 ± 0.09 and 0.09 ± 0.03 mm/year, P < 0.01). The incidence of osteolysis for the Enduron group was higher than that of the Trilogy group (33.3 % and 12 %, P = 0.04). Under transmission electron microscopy, the Enduron group had more than 82 % of the particles less than 1.0 μm in size and more than 57 % of the particles less than 0.5 μm.
CONCLUSION: The long-term performance of Enduron liners was worse than that of Trilogy liners. Further clinical follow-up may be necessary in patients with Enduron PE liners in order to avoid catastrophic complications.

Entities:  

Keywords:  Enduron polyethylene liner; Follow up; Total hip arthroplasty; Wear

Mesh:

Substances:

Year:  2016        PMID: 27178441     DOI: 10.1007/s00264-016-3217-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  29 in total

1.  Long-term follow-up of primary total hip arthroplasty with the Alloclassic Variall system.

Authors:  Josef Hochreiter; Giovanni Brusaferri; Klaus Kirschbichler; Katja Emmanuel
Journal:  Int Orthop       Date:  2015-08-18       Impact factor: 3.075

2.  The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene.

Authors:  Daniel M Estok; Charles R Bragdon; Gordon R Plank; Anna Huang; Orhun K Muratoglu; William H Harris
Journal:  J Arthroplasty       Date:  2005-02       Impact factor: 4.757

3.  A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners.

Authors:  C Anderson Engh; Adam S Stepniewski; Stuart D Ginn; Sarah E Beykirch; Christi J Sychterz-Terefenko; Robert H Hopper; Charles A Engh
Journal:  J Arthroplasty       Date:  2006-09       Impact factor: 4.757

4.  Effect of head surface roughness and sterilization on wear of UHMWPE acetabular cups.

Authors:  A Jedenmalm; S Affatato; P Taddei; W Leardini; U W Gedde; C Fagnano; M Viceconti
Journal:  J Biomed Mater Res A       Date:  2009-09-15       Impact factor: 4.396

5.  [Distribution of UHMWPE wear particles in periprosthetic tissues of total hip replacements].

Authors:  D Pokorný; M Slouf; F Veselý; P Fulín; D Jahoda; A Sosna
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2010-04       Impact factor: 0.531

6.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

7.  The long-term results of Charnley low-friction arthroplasty in young patients who have congenital dislocation, degenerative osteoarthrosis, or rheumatoid arthritis.

Authors:  D H Sochart; M L Porter
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

8.  The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.

Authors:  Geraint E R Thomas; David J Simpson; Shahid Mehmood; Adrian Taylor; Peter McLardy-Smith; Harinderjit Singh Gill; David W Murray; Siôn Glyn-Jones
Journal:  J Bone Joint Surg Am       Date:  2011-04-20       Impact factor: 5.284

Review 9.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

10.  Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.

Authors:  Richard W McCalden; Steven J MacDonald; Cecil H Rorabeck; Robert B Bourne; David G Chess; Kory D Charron
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

View more
  5 in total

1.  Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.

Authors:  Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2016-11-04       Impact factor: 3.075

2.  Delay of total hip arthroplasty to advanced stage worsens post-operative hip motion in patients with femoral head osteonecrosis.

Authors:  Woo-Lam Jo; Young-Kyun Lee; Yong-Chan Ha; Tae-Young Kim; Kyung-Hoi Koo
Journal:  Int Orthop       Date:  2018-04-26       Impact factor: 3.075

3.  Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements.

Authors:  Harman Khatkar; Harry Hothi; Danielle de Villiers; Christian Lausmann; Daniel Kendoff; Thorsten Gehrke; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-10-25       Impact factor: 3.075

Review 4.  A prospective osseointegration retrieval analysis of second generation cementless shells.

Authors:  M Curtin; E Pomeroy; M Grigoras; T Murphy; Fiachra E Rowan
Journal:  J Clin Orthop Trauma       Date:  2022-06-03

5.  Long-Term Results of Hip Arthroplasty Using Extensive Porous-Coated Stem-A Minimum Follow-Up of 15 Years.

Authors:  Myung Hoon Park; Yung Hun Youn; Joon Soon Kang; Kyoung Ho Moon
Journal:  Geriatr Orthop Surg Rehabil       Date:  2019-12-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.