Literature DB >> 10611861

Assessment of polyethylene wear in total hip replacement.

P A Devane1, J G Horne.   

Abstract

The three-dimensional technique is a method for the measurement of polyethylene wear in patients with total hip joint replacement. Application of image processing technology allows automation of point selection from digital images of radiographs scanned into the computer. Validation of image processing modifications reveals a three-fold increase in accuracy and a 40-fold increase in reproducibility compared with manual input of points from a digitizer during bench testing. A review of three-dimensional technique application to clinical patients gives information on the factors that influence polyethylene wear. Increasing age, activity level, femoral head size, decreasing polyethylene thickness, and insertion of total hip prostheses without cement all increase polyethylene wear. Restoration of femoral offset during total hip replacement seems to decreases polyethylene wear. No apparent difference in polyethylene wear rate could be found between two groups of patients, one group had a stainless steel-polyethylene articulation and the other had a ceramic-polyethylene articulation. Measurement of the serial polyethylene wear of individual patients reveals a high rate of femoral head penetration during the first 2 years after total hip replacement using metal-backed acetabular components inserted without cement. Interpretation of this femoral head penetration as true polyethylene wear may be erroneous, however, because creep of the polyethylene and acetabular liner movement within its metal shell cannot be measured.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10611861     DOI: 10.1097/00003086-199912000-00007

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

2.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

4.  What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17-year followup of a randomized controlled trial.

Authors:  Kristoff Corten; Robert B Bourne; Kory D Charron; Keegan Au; Cecil H Rorabeck
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

5.  Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  George K Karidakis; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

Review 6.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

7.  Acetabular UHMWPE survival and wear changes with different manufacturing techniques.

Authors:  John B Meding; E Michael Keating; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

8.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

9.  Factors influencing the revision rate of Zweymueller acetabular cup.

Authors:  H Effenberger; T Ramsauer; U Dorn; M Imhof
Journal:  Int Orthop       Date:  2004-03-31       Impact factor: 3.075

10.  Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Joel Poupon; Marc-Antoine Rousseau; Carine Roy; Philippe Ravaud; Yves Catonné
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.