Literature DB >> 20177988

Comparative study of jaws with multislice computed tomography and cone-beam computed tomography.

G Carrafiello1, M Dizonno, V Colli, S Strocchi, S Pozzi Taubert, A Leonardi, A Giorgianni, M Barresi, A Macchi, E Bracchi, L Conte, C Fugazzola.   

Abstract

PURPOSE: The aim of this study was to compare the dosimetric and diagnostic performance of multislice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the study of the dental arches.
MATERIALS AND METHODS: Effective dose and dose to the main organs of the head and neck were evaluated by means of thermoluminescent dosimeters (TLDs) placed in an Alderson Rando anthropomorphic phantom and using a standard CBCT protocol and an optimised MSCT protocol. Five patients with occlusal plane ranging from 54 cm to 59 cm who needed close follow-up (range 1-3 months) underwent both examinations. Image quality obtained with CBCT and MSCT was evaluated.
RESULTS: Effective dose and dose to the main organs of the head and neck were higher for MSCT than for CBCT. Image quality of CBCT was judged to be equivalent to that of MSCT for visualising teeth and bone but inferior for visualising soft tissues. Beam-hardening artefacts due to dental-care material and implants were weaker at CBCT than at MSCT.
CONCLUSIONS: When panoramic radiography is not sufficient in the study of the teeth and jaw bones, CBCT can provide identical information to MSCT, with a considerable dose reduction. MSCT is, however, indicated when evaluation of soft tissue is required.

Entities:  

Mesh:

Year:  2010        PMID: 20177988     DOI: 10.1007/s11547-010-0520-5

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  20 in total

1.  Radiation dose in dental radiology.

Authors:  M Cohnen; J Kemper; O Möbes; J Pawelzik; U Mödder
Journal:  Eur Radiol       Date:  2001-06-01       Impact factor: 5.315

2.  Comparison of patient dose from imaging protocols for dental implant planning using conventional radiography and computed tomography.

Authors:  A R Lecomber; Y Yoneyama; D J Lovelock; T Hosoi; A M Adams
Journal:  Dentomaxillofac Radiol       Date:  2001-09       Impact factor: 2.419

3.  Dose reduction in maxillofacial imaging using low dose Cone Beam CT.

Authors:  Kostas Tsiklakis; Catherine Donta; Sophia Gavala; Kety Karayianni; Vasiliki Kamenopoulou; Costas J Hourdakis
Journal:  Eur J Radiol       Date:  2005-06-22       Impact factor: 3.528

4.  Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT.

Authors:  F G Draenert; E Coppenrath; P Herzog; S Müller; U G Mueller-Lisse
Journal:  Dentomaxillofac Radiol       Date:  2007-05       Impact factor: 2.419

5.  Cervical soft tissue imaging using a mobile CBCT scanner with a flat panel detector in comparison with corresponding CT and MRI data sets.

Authors:  Max Heiland; Philipp Pohlenz; Marco Blessmann; Christian R Habermann; Lars Oesterhelweg; Philipp C Begemann; Christian Schmidgunst; Felix A S Blake; Klaus Püschel; Rainer Schmelzle; Dirk Schulze
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2007-09-27

6.  Techniques for measurement of dose width product in panoramic dental radiography.

Authors:  P Doyle; C J Martin; J Robertson
Journal:  Br J Radiol       Date:  2006-02       Impact factor: 3.039

7.  Clinical applications of cone-beam computed tomography in dental practice.

Authors:  William C Scarfe; Allan G Farman; Predag Sukovic
Journal:  J Can Dent Assoc       Date:  2006-02       Impact factor: 1.316

8.  A comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT.

Authors:  Miet Loubele; Maria Eugenia Guerrero; Reinhide Jacobs; Paul Suetens; Daniel van Steenberghe
Journal:  Int J Oral Maxillofac Implants       Date:  2007 May-Jun       Impact factor: 2.804

9.  Accuracy of measurements of mandibular anatomy in cone beam computed tomography images.

Authors:  John B Ludlow; William Stewart Laster; Meit See; L'Tanya J Bailey; H Garland Hershey
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-08-04

10.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

View more
  24 in total

1.  Effect of electric potential and current on mandibular linear measurements in cone beam CT.

Authors:  S Panmekiate; W Apinhasmit; A Petersson
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  Accuracy of templates for navigated implantation made by rapid prototyping with DICOM datasets of cone beam computer tomography (CBCT).

Authors:  Jochen Weitz; Herbert Deppe; Sebastian Stopp; Tim Lueth; Steffen Mueller; Bettina Hohlweg-Majert
Journal:  Clin Oral Investig       Date:  2010-09-21       Impact factor: 3.573

3.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

4.  Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs.

Authors:  R Patcas; G Markic; L Müller; O Ullrich; T Peltomäki; C J Kellenberger; C A Karlo
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

5.  Assessing the need for computed tomography for lower-third-molar extraction: a survey among 322 dentists.

Authors:  S Sivolella; G Boccuzzo; E Gasparini; G De Conti; M Berengo
Journal:  Radiol Med       Date:  2011-04-19       Impact factor: 3.469

Review 6.  Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review.

Authors:  A Al-Okshi; C Lindh; H Salé; M Gunnarsson; M Rohlin
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

7.  Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules.

Authors:  Nicola Rotolo; Chiara Floridi; Andrea Imperatori; Federico Fontana; Anna Maria Ierardi; Monica Mangini; Veronica Arlant; Giuseppe De Marchi; Raffaele Novario; Lorenzo Dominioni; Carlo Fugazzola; Gianpaolo Carrafiello
Journal:  Eur Radiol       Date:  2015-06-06       Impact factor: 5.315

8.  Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography.

Authors:  V Hirschinger; S Hanke; U Hirschfelder; E Hofmann
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

9.  Influence of cone beam CT scanning parameters on grey value measurements at an implant site.

Authors:  A Parsa; N Ibrahim; B Hassan; A Motroni; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

Review 10.  Clinical guidelines for dental cone-beam computed tomography.

Authors:  Takafumi Hayashi; Yoshinori Arai; Toru Chikui; Sachiko Hayashi-Sakai; Kazuya Honda; Hiroko Indo; Taisuke Kawai; Kaoru Kobayashi; Shumei Murakami; Masako Nagasawa; Munetaka Naitoh; Eiji Nakayama; Yutaka Nikkuni; Hideyoshi Nishiyama; Noriaki Shoji; Shigeaki Suenaga; Ray Tanaka
Journal:  Oral Radiol       Date:  2018-01-11       Impact factor: 1.852

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.