Literature DB >> 15978765

Dose reduction in maxillofacial imaging using low dose Cone Beam CT.

Kostas Tsiklakis1, Catherine Donta, Sophia Gavala, Kety Karayianni, Vasiliki Kamenopoulou, Costas J Hourdakis.   

Abstract

OBJECTIVES: (a) To measure the absorbed dose at certain anatomical sites of a RANDO phantom and to estimate the effective dose in radiographic imaging of the jaws using low dose Cone Beam computed tomography (CBCT) and (b) to compare the absorbed and the effective doses between thyroid and cervical spine shielding and non-shielding techniques. STUDY
DESIGN: Thermoluminescent dosimeters (TLD-100) were placed at 14 sites in a RANDO phantom, using a Cone Beam CT device (Newtom, Model QR-DVT 9000, Verona, Italy). Dosimetry was carried out applying two techniques: in the first, there was no shielding device used while in the second one, a shielding device (EUREKA!, TRIX) was applied for protection of the thyroid gland and the cervical spine. Effective dose was estimated according to ICRP(60) report (E(ICRP)). An additional estimation of the effective dose was accomplished including the doses of the salivary glands (E(SAL)). A Wilcoxon Signed Ranks Test was used for statistical analysis.
RESULTS: In the non-shielding technique the absorbed doses ranged from 0.16 to 1.67 mGy, while 0.32 and 1.28 mGy were the doses to the thyroid and the cervical spine, respectively. The effective dose, E(ICRP), was 0.035 mSv and the E(SAL) was 0.064 mSv. In the shielding technique, the absorbed doses ranged from 0.09 to 1.64 mGy, while 0.18 and 0.95 mGy were the respective values for the thyroid and the cervical spine. The effective dose, E(ICRP), was 0.023 mSv and E(SAL) was 0.052 mSv.
CONCLUSIONS: The use of CBCT for maxillofacial imaging results in a reduced absorbed and effective dose. The use of lead shielding leads to a further reduction of the absorbed doses of thyroid and cervical spine, as well as the effective dose.

Entities:  

Mesh:

Year:  2005        PMID: 15978765     DOI: 10.1016/j.ejrad.2005.05.011

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  63 in total

1.  Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology.

Authors:  A Endo; T Katoh; I Kobayashi; R Joshi; J Sur; T Okano
Journal:  Dentomaxillofac Radiol       Date:  2011-11-24       Impact factor: 2.419

2.  Effective doses from cone beam CT investigation of the jaws.

Authors:  J Davies; B Johnson; Na Drage
Journal:  Dentomaxillofac Radiol       Date:  2012-01       Impact factor: 2.419

3.  Evaluation of a cone beam CT artefact reduction algorithm.

Authors:  B Bechara; C A McMahan; H Geha; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-02-23       Impact factor: 2.419

4.  Digital method for quantification of circumferential periodontal bone level using cone beam CT.

Authors:  Jonathan Fleiner; Christian Hannig; Dirk Schulze; Andres Stricker; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2012-03-21       Impact factor: 3.573

5.  Dose reduction of cone beam CT scanning for the entire oral and maxillofacial regions with thyroid collars.

Authors:  X M Qu; G Li; G C H Sanderink; Z Y Zhang; X C Ma
Journal:  Dentomaxillofac Radiol       Date:  2012-07       Impact factor: 2.419

6.  Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms.

Authors:  C Theodorakou; A Walker; K Horner; R Pauwels; R Bogaerts; R Jacobs
Journal:  Br J Radiol       Date:  2012-02       Impact factor: 3.039

7.  Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields.

Authors:  Anna Kelaranta; Marja Ekholm; Paula Toroi; Mika Kortesniemi
Journal:  Dentomaxillofac Radiol       Date:  2015-08-27       Impact factor: 2.419

8.  Cone beam CT: a current overview of devices.

Authors:  A Nemtoi; C Czink; D Haba; A Gahleitner
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

9.  Comparative study of jaws with multislice computed tomography and cone-beam computed tomography.

Authors:  G Carrafiello; M Dizonno; V Colli; S Strocchi; S Pozzi Taubert; A Leonardi; A Giorgianni; M Barresi; A Macchi; E Bracchi; L Conte; C Fugazzola
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

10.  Direct comparison of conventional radiography and cone-beam CT in small bone and joint trauma.

Authors:  E De Smet; G De Praeter; K L A Verstraete; K Wouters; Luc De Beuckeleer; F M H M Vanhoenacker
Journal:  Skeletal Radiol       Date:  2015-03-12       Impact factor: 2.199

View more