Literature DB >> 20857309

Accuracy of templates for navigated implantation made by rapid prototyping with DICOM datasets of cone beam computer tomography (CBCT).

Jochen Weitz1, Herbert Deppe, Sebastian Stopp, Tim Lueth, Steffen Mueller, Bettina Hohlweg-Majert.   

Abstract

The aim of this study is to evaluate the accuracy of a surgical template-aided implant placement produced by rapid prototyping using a DICOM dataset from cone beam computer tomography (CBCT). On the basis of CBCT scans (Sirona® Galileos), a total of ten models were produced using a rapid-prototyping three-dimensional printer. On the same patients, impressions were performed to compare fitting accuracy of both methods. From the models made by impression, templates were produced and accuracy was compared and analyzed with the rapid-prototyping model. Whereas templates made by conventional procedure had an excellent accuracy, the fitting accuracy of those produced by DICOM datasets was not sufficient. Deviations ranged between 2.0 and 3.5 mm, after modification of models between 1.4 and 3.1 mm. The findings of this study suggest that the accuracy of the low-dose Sirona Galileos® DICOM dataset seems to show a high deviation, which is not useable for accurate surgical transfer for example in implant surgery.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20857309     DOI: 10.1007/s00784-010-0468-9

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  27 in total

1.  Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy.

Authors:  Arne Wagner; Felix Wanschitz; Wolfgang Birkfellner; Konstantin Zauza; Clemens Klug; Kurt Schicho; Franz Kainberger; Christian Czerny; Helmar Bergmann; Rolf Ewers
Journal:  Clin Oral Implants Res       Date:  2003-06       Impact factor: 5.977

2.  Implant imaging for the dentist.

Authors:  Muralidhar Mupparapu; Steven R Singer
Journal:  J Can Dent Assoc       Date:  2004-01       Impact factor: 1.316

3.  Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine.

Authors:  Thomas Fortin; Guillaume Champleboux; Silvio Bianchi; Hervé Buatois; Jean-Loup Coudert
Journal:  Clin Oral Implants Res       Date:  2002-12       Impact factor: 5.977

4.  Generation of three-dimensional prototype models based on cone beam computed tomography.

Authors:  J Th Lambrecht; D C Berndt; R Schumacher; M Zehnder
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-11-15       Impact factor: 2.924

Review 5.  A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry.

Authors:  David Schneider; Pascal Marquardt; Marcel Zwahlen; Ronald E Jung
Journal:  Clin Oral Implants Res       Date:  2009-09       Impact factor: 5.977

6.  Loma Linda guide: a stereolithographically designed surgical template: technique paper.

Authors:  Alejandro Kleinman; Francisco Leyva; Jaime Lozada; Rishi D Patel
Journal:  J Oral Implantol       Date:  2009       Impact factor: 1.779

7.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

8.  Comparative study of jaws with multislice computed tomography and cone-beam computed tomography.

Authors:  G Carrafiello; M Dizonno; V Colli; S Strocchi; S Pozzi Taubert; A Leonardi; A Giorgianni; M Barresi; A Macchi; E Bracchi; L Conte; C Fugazzola
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

9.  A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study.

Authors:  Daniel van Steenberghe; Roland Glauser; Ulf Blombäck; Matts Andersson; Filip Schutyser; Andreas Pettersson; Inger Wendelhag
Journal:  Clin Implant Dent Relat Res       Date:  2005       Impact factor: 3.932

10.  Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients.

Authors:  Anna M Sanna; Liene Molly; Daniel van Steenberghe
Journal:  J Prosthet Dent       Date:  2007-06       Impact factor: 3.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.