Literature DB >> 20857166

Accuracy of CBCT measurements of a human skull.

Kivanç Kamburoğlu1, Eray Kolsuz, Hakan Kurt, Cenk Kiliç, Tuncer Özen, Candan Semra Paksoy.   

Abstract

The purpose of this study is to assess the accuracy and reproducibility of cone-beam computed tomography (CBCT) measurements of a human dry skull by comparing them to direct digital caliper measurements. Heated gutta-percha was used to mark 13 specific distances on a human skull, and the distances were directly measured using a digital caliper and on CBCT images obtained with Iluma (3M Imtec, OK, USA) and 3D Accuitomo 170 (3D Accuitomo; J Morita Mfg. Corp., Kyoto, Japan) CBCT imaging systems. Iluma images were obtained at 120 kVp and 3.8 mA and reconstructed using voxel sizes of 0.2 and 0.3 mm(3). Accuitomo images were obtained at 60 kVp and 2 mA and a voxel size of 0.250 mm(3). In addition, 3-D reconstructions were produced from images obtained from both systems. All measurements were made independently by three trained observers and were repeated after an interval of 1 week. Agreement between observers and image type was assessed by calculating Pearson correlation coefficients, with a level of significance set at p < 0.05. Pearson correlation coefficients between readings ranged from 0.995 to 1 for all image types. Correlations among observers were also very high, ranging from 0.992 to 1 for the first reading and from 0.992 to 1 for the second reading for the different image types. All CBCT image measurements were identical and highly correlated with digital caliper measurements. Accuracy of measurements of various distances on a human skull obtained from different CBCT units and image types is comparable to that of digital caliper measurements.

Entities:  

Mesh:

Year:  2011        PMID: 20857166      PMCID: PMC3180546          DOI: 10.1007/s10278-010-9339-9

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  29 in total

1.  An iterative approach to the beam hardening correction in cone beam CT.

Authors:  J Hsieh; R C Molthen; C A Dawson; R H Johnson
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  Accuracy in measurement of distance using limited cone-beam computerized tomography.

Authors:  Kaoru Kobayashi; Shinji Shimoda; Yoichi Nakagawa; Akira Yamamoto
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Mar-Apr       Impact factor: 2.804

3.  Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom).

Authors:  C A Lascala; J Panella; M M Marques
Journal:  Dentomaxillofac Radiol       Date:  2004-09       Impact factor: 2.419

4.  Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography.

Authors:  Michael L Hilgers; William C Scarfe; James P Scheetz; Allan G Farman
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-12       Impact factor: 2.650

5.  Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT.

Authors:  J B Ludlow; L E Davies-Ludlow; S L Brooks; W B Howerton
Journal:  Dentomaxillofac Radiol       Date:  2006-07       Impact factor: 2.419

6.  Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT.

Authors:  F G Draenert; E Coppenrath; P Herzog; S Müller; U G Mueller-Lisse
Journal:  Dentomaxillofac Radiol       Date:  2007-05       Impact factor: 2.419

7.  Clinical applications of cone-beam computed tomography in dental practice.

Authors:  William C Scarfe; Allan G Farman; Predag Sukovic
Journal:  J Can Dent Assoc       Date:  2006-02       Impact factor: 1.316

8.  Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging.

Authors:  Robert A Mischkowski; Reinhard Pulsfort; Lutz Ritter; Jörg Neugebauer; Hans Georg Brochhagen; Erwin Keeve; Joachim E Zöller
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2007-07-05

9.  Accuracy of measurements of mandibular anatomy in cone beam computed tomography images.

Authors:  John B Ludlow; William Stewart Laster; Meit See; L'Tanya J Bailey; H Garland Hershey
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-08-04

10.  Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography.

Authors:  Mazyar Moshiri; William C Scarfe; Michael L Hilgers; James P Scheetz; Anibal M Silveira; Allan G Farman
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-10       Impact factor: 2.650

View more
  9 in total

1.  Comparison of the accuracy of full head cone beam CT images obtained using a large field of view and stitched images.

Authors:  Mehmet Ozgur Ozemre; Ayse Gulsahi
Journal:  Dentomaxillofac Radiol       Date:  2018-06-19       Impact factor: 2.419

2.  The Use of Cone Beam Computed Tomography in Assessing the Insertion of Bone Conduction Hearing Implants.

Authors:  Tim George Ate Calon; Martin Lars Johansson; Elske Larissa van den Burg; Anna Maria Louisa Janssen; Marc van Hoof; Robert Jan Stokroos
Journal:  Front Surg       Date:  2017-07-24

3.  Comparative study of mandibular linear measurements obtained by cone beam computed tomography and digital calipers.

Authors:  Pablo Tarazona-Álvarez; Javier Romero-Millán; David Peñarrocha-Oltra; María Á Fuster-Torres; Beatriz Tarazona; Miguel Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2014-07-01

4.  Evaluation of diagnostic accuracy and dimensional measurements by using CBCT in mandibular first molars.

Authors:  Saeed Asgary; Sima Nikneshan; Alireza Akbarzadeh-Bagheban; Naghmeh Emadi
Journal:  J Clin Exp Dent       Date:  2016-02-01

5.  Three-dimensional measurement of periodontal surface area for quantifying inflammatory burden.

Authors:  Sa-Beom Park; So-Youn An; Won-Jeong Han; Jong-Tae Park
Journal:  J Periodontal Implant Sci       Date:  2017-06-28       Impact factor: 2.614

6.  Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography.

Authors:  Nathália Cristine da Silva; Maurício Barriviera; José Luiz Cintra Junqueira; Francine Kühl Panzarella; Ricardo Raitz
Journal:  Imaging Sci Dent       Date:  2017-03-21

7.  The efficacy of ultrasonography in monitoring the healing of jaw lesions.

Authors:  Obai Zainedeen; Iyad Al Haffar; Nabil Kochaji; George Wassouf
Journal:  Imaging Sci Dent       Date:  2018-09-18

8.  Gaining surgical access for repositioning the inferior alveolar neurovascular bundle.

Authors:  Saif Yousif Abdullah Al-Siweedi; P Nambiar; P Shanmuhasuntharam; W C Ngeow
Journal:  ScientificWorldJournal       Date:  2014-04-24

9.  Facial Flatness Indices: A Comparison of Two Methods of Assessment.

Authors:  Chimène Chalala; Maria Saadeh; Fouad Ayoub
Journal:  J Clin Imaging Sci       Date:  2020-10-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.