Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography.

V Hirschinger1, S Hanke, U Hirschfelder, E Hofmann.   

Abstract

OBJECTIVES: The purpose of this study was to quantify artifacts caused by different bracket systems in cone-beam computed tomography (CBCT) and multislice computed tomography (MSCT) scans.
METHODS: Orthodontic brackets of four different systems were consecutively bonded to the surface of a residual molar on a human cadaveric mandible. One MSCT system and three CBCT units were used to scan each of the four bonded brackets, in addition to obtaining a blank reference scan of the tooth surface. All datasets were registered to the reference dataset using visualization software (Analyze 11.0® by AnalyzeDirect). Artifact-related reductions in image quality were expressed in percent of theoretical maximum standard deviations (SD) obtained for the gray values of the adjacent voxels, with higher percentages correlating more pronounced artifacts.
RESULTS: Both the SD percentages for three defined line profiles and their mean values were almost invariably higher with the MSCT system than with the CBCT units. Looking into the individual SD percentages, two of the CBCT units (Pax Zenith 3D® and Picasso Trio®; both Vatech) produced higher values than the MSCT system (SOMATOM Definition AS+®; Siemens) in some line profiles. The titanium bracket, in particular, was associated with marked differences between the two scanner technologies, as the mean artifact intensities from this bracket were particularly high with the MSCT unit and relatively low with the CBCT units. The artifact intensities observed with the other three bracket systems varied widely depending on which scanner was used.
CONCLUSION: Different artifact intensities were noted depending on the composition of the bracket system and on the scanner technology (MSCT/CBCT). While the artifacts manifested themselves differently with different scanners, their adverse effects were comparable. However, given the variable severity of the artifacts observed depending on the materials scanned and the scanners used, a blanket recommendation for or against MSCT or CBCT units cannot be given on the basis of this study.

Entities:  

Mesh:

Year:  2015        PMID: 25744093     DOI: 10.1007/s00056-014-0278-9

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  27 in total

1.  Subsecond multi-slice computed tomography: basics and applications.

Authors:  K Klingenbeck-Regn; S Schaller; T Flohr; B Ohnesorge; A F Kopp; U Baum
Journal:  Eur J Radiol       Date:  1999-08       Impact factor: 3.528

2.  Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT.

Authors:  F G Draenert; E Coppenrath; P Herzog; S Müller; U G Mueller-Lisse
Journal:  Dentomaxillofac Radiol       Date:  2007-05       Impact factor: 2.419

Review 3.  Principles of CT: radiation dose and image quality.

Authors:  Lee W Goldman
Journal:  J Nucl Med Technol       Date:  2007-11-15

4.  A novel forward projection-based metal artifact reduction method for flat-detector computed tomography.

Authors:  Daniel Prell; Yiannis Kyriakou; Marcel Beister; Willi A Kalender
Journal:  Phys Med Biol       Date:  2009-10-14       Impact factor: 3.609

5.  On cone-beam computed tomography artifacts induced by titanium implants.

Authors:  Ralf Kurt Willy Schulze; Dorothea Berndt; Bernd d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2009-10-21       Impact factor: 5.977

6.  Comparative study of jaws with multislice computed tomography and cone-beam computed tomography.

Authors:  G Carrafiello; M Dizonno; V Colli; S Strocchi; S Pozzi Taubert; A Leonardi; A Giorgianni; M Barresi; A Macchi; E Bracchi; L Conte; C Fugazzola
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

7.  Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction.

Authors:  Jeffrey F Williamson; Bruce R Whiting; Jasenka Benac; Ryan J Murphy; G James Blaine; Joseph A O'Sullivan; David G Politte; Donald L Snyder
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

8.  Metal artifacts from posterior mandibular implants as seen in CBCT.

Authors:  Munetaka Naitoh; Kiyonobu Saburi; Kenichi Gotoh; Kenichi Kurita; Eiichiro Ariji
Journal:  Implant Dent       Date:  2013-04       Impact factor: 2.454

9.  Radiological evaluation of changes in the gonial angle after teeth extraction and wearing of dentures: a 3-year longitudinal study.

Authors:  Nuran Yanikoğlu; Baykal Yilmaz
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-04-16

10.  Influence of dental metallic artifact from multislice CT in the assessment of simulated mandibular lesions.

Authors:  Andréia Perrella; Patricia M L Lopes; Rodney G Rocha; Marlene Fenyo-Pereira; Marcelo G P Cavalcanti
Journal:  J Appl Oral Sci       Date:  2010 Mar-Apr       Impact factor: 2.698

View more
  3 in total

Review 1.  Cone-Beam Computed Tomography in Orthodontics.

Authors:  Ahmad Abdelkarim
Journal:  Dent J (Basel)       Date:  2019-09-02

2.  Fusion of intra-oral scans in cone-beam computed tomography scans.

Authors:  F Baan; R Bruggink; J Nijsink; T J J Maal; E M Ongkosuwito
Journal:  Clin Oral Investig       Date:  2020-06-03       Impact factor: 3.573

3.  Robust and Accurate Mandible Segmentation on Dental CBCT Scans Affected by Metal Artifacts Using a Prior Shape Model.

Authors:  Bingjiang Qiu; Hylke van der Wel; Joep Kraeima; Haye Hendrik Glas; Jiapan Guo; Ronald J H Borra; Max Johannes Hendrikus Witjes; Peter M A van Ooijen
Journal:  J Pers Med       Date:  2021-05-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.