Literature DB >> 20099330

Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T.

Michael Schär1, Evert-Jan Vonken, Matthias Stuber.   

Abstract

High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance frequency f(0) and the radiofrequency power to generate the intended local B(1)+ field. In this work, dual echo time B(0)-map and dual flip angle B(1)+-map acquisition methods are combined to acquire multislice B(0)- and B(1)+-maps simultaneously covering the entire heart in a single breath hold of 18 heartbeats. A previously proposed excitation pulse shape dependent slice profile correction is tested and applied to reduce systematic errors of the multislice B(1)+-map. Localized higher-order shim correction values including the zero-order terms for frequency f(0) and radiofrequency power can be determined based on the acquired B(0)- and B(1)+-maps. This method has been tested in 7 healthy adult human subjects at 3 T and improved the B(0) field homogeneity (standard deviation) from 60 Hz to 35 Hz and the average B(1)+ field from 77% to 100% of the desired B(1)+ field when compared to more commonly used preparation methods.

Entities:  

Mesh:

Year:  2010        PMID: 20099330      PMCID: PMC2987721          DOI: 10.1002/mrm.22234

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Application of finite difference time domain method for the design of birdcage RF head coils using multi-port excitations.

Authors:  T S Ibrahim; R Lee; B A Baertlein; A Kangarlu; P L Robitaille
Journal:  Magn Reson Imaging       Date:  2000-07       Impact factor: 2.546

2.  Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency.

Authors:  Vibhas S Deshpande; Steven M Shea; Debiao Li
Journal:  Magn Reson Med       Date:  2003-05       Impact factor: 4.668

3.  Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T.

Authors:  Robert L Greenman; John E Shirosky; Robert V Mulkern; Neil M Rofsky
Journal:  J Magn Reson Imaging       Date:  2003-06       Impact factor: 4.813

4.  Navigator gating and volume tracking for double-triggered cardiac proton spectroscopy at 3 Tesla.

Authors:  Michael Schär; Sebastian Kozerke; Peter Boesiger
Journal:  Magn Reson Med       Date:  2004-06       Impact factor: 4.668

5.  Cardiac SSFP imaging at 3 Tesla.

Authors:  Michael Schär; Sebastian Kozerke; Stefan E Fischer; Peter Boesiger
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

6.  Design and use of tailored hard-pulse trains for uniformed saturation of myocardium at 3 Tesla.

Authors:  Kyunghyun Sung; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

7.  Imaging of the active B1 field in vivo.

Authors:  R Stollberger; P Wach
Journal:  Magn Reson Med       Date:  1996-02       Impact factor: 4.668

8.  Simulation of B1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field.

Authors:  R W Singerman; T J Denison; H Wen; R S Balaban
Journal:  J Magn Reson       Date:  1997-03       Impact factor: 2.229

Review 9.  Spatial localization in NMR spectroscopy in vivo.

Authors:  P A Bottomley
Journal:  Ann N Y Acad Sci       Date:  1987       Impact factor: 5.691

10.  Java-based graphical user interface for the MRUI quantitation package.

Authors:  A Naressi; C Couturier; J M Devos; M Janssen; C Mangeat; R de Beer; D Graveron-Demilly
Journal:  MAGMA       Date:  2001-05       Impact factor: 2.533

View more
  32 in total

1.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

3.  A multichannel, real-time MRI RF power monitor for independent SAR determination.

Authors:  Abdel-Monem M El-Sharkawy; Di Qian; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

4.  Deep residual network for off-resonance artifact correction with application to pediatric body MRA with 3D cones.

Authors:  David Y Zeng; Jamil Shaikh; Signy Holmes; Ryan L Brunsing; John M Pauly; Dwight G Nishimura; Shreyas S Vasanawala; Joseph Y Cheng
Journal:  Magn Reson Med       Date:  2019-05-22       Impact factor: 4.668

5.  Targeted radiofrequency field mapping using 3D reduced field-of-view-catalyzed double-angle method.

Authors:  Dingxin Wang; Sven Zuehlsdorff; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Imaging       Date:  2011-06-25       Impact factor: 2.546

6.  Transmit B1+ field inhomogeneity and T1 estimation errors in breast DCE-MRI at 3 tesla.

Authors:  Kyunghyun Sung; Bruce L Daniel; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2013-01-04       Impact factor: 4.813

7.  Natively fat-suppressed 5D whole-heart MRI with a radial free-running fast-interrupted steady-state (FISS) sequence at 1.5T and 3T.

Authors:  Jessica A M Bastiaansen; Davide Piccini; Lorenzo Di Sopra; Christopher W Roy; John Heerfordt; Robert R Edelman; Ioannis Koktzoglou; Jérôme Yerly; Matthias Stuber
Journal:  Magn Reson Med       Date:  2019-08-27       Impact factor: 4.668

8.  Three-dimensional amide proton transfer MR imaging of gliomas: Initial experience and comparison with gadolinium enhancement.

Authors:  Jinyuan Zhou; He Zhu; Michael Lim; Lindsay Blair; Alfredo Quinones-Hinojosa; Steven A Messina; Charles G Eberhart; Martin G Pomper; John Laterra; Peter B Barker; Peter C M van Zijl; Jaishri O Blakeley
Journal:  J Magn Reson Imaging       Date:  2013-02-25       Impact factor: 4.813

9.  Temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ): Dynamic myocardial T1 mapping using a cine steady-state look-locker approach.

Authors:  Sebastian Weingärtner; Chetan Shenoy; Benedikt Rieger; Lothar R Schad; Jeanette Schulz-Menger; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

10.  The effects of concomitant gradients on chemical shift encoded MRI.

Authors:  Timothy J Colgan; Diego Hernando; Samir D Sharma; Scott B Reeder
Journal:  Magn Reson Med       Date:  2016-09-21       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.