Simulation of B1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field.

R W Singerman1, T J Denison, H Wen, R S Balaban.   

Abstract

Two issues that pertain to the optimal static magnetic field for cardiac MRI were addressed: intrinsic signal-to-noise ratio (ISNR) and radiofrequency power deposition. From 1.5 to 9.5 T, proton Larmor frequencies of 63 to 400 MHz, numerical simulations were performed of the RF fields from a surface coil and a body coil loaded by a heterogeneous, three-dimensional, symmetric model of the human chest. The RF field distribution, the power required to produce the RF field, and the ISNR at the center of the heart were computed. The model was validated by comparison with experimental data up to 4 T. The RF field distortion was quantified and found to increase linearly up to 6 T due mostly to dielectric resonance modes. Body coil simulations beyond 6 T showed the onset of higher-order modes at the center of the heart. A range of expected RF power requirements was constructed as a function of field up to 9.5 T for surface coils and up to 6.8 T for body coils. Over this range of static field, ISNR for a constant coil geometry was bracketed by an upper limit that was slightly greater than linear with field and a lower limit that was slightly less than linear with field. The RF power and ISNR showed a strong dependence on chest thickness at 1.5 and 4.0 T. Additionally, independent of chest thickness, the model predicts a lower limit of a factor of 5 increase in RF power as the static field is increased from 1.5 to 4 T. Implications for imaging with other nuclei are discussed. Methods for checking the self-consistency of electrodynamic simulations are presented.

Entities:  

Mesh:

Year:  1997        PMID: 9245362     DOI: 10.1006/jmre.1996.1073

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  17 in total

Review 1.  Cardiac magnetic resonance at high field: promises and problems.

Authors:  Ahmed M Gharib; Abdalla Elagha; Roderic I Pettigrew
Journal:  Curr Probl Diagn Radiol       Date:  2008 Mar-Apr

2.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements.

Authors:  Gregory J Metzger; Carl Snyder; Can Akgun; Tommy Vaughan; Kamil Ugurbil; Pierre-Francois Van de Moortele
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

3.  The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T.

Authors:  H Wen; T J Denison; R W Singerman; R S Balaban
Journal:  J Magn Reson       Date:  1997-03       Impact factor: 2.229

4.  Calculations of B1 Distribution, Specific Energy Absorption Rate, and Intrinsic Signal-to-Noise Ratio for a Body-Size Birdcage Coil Loaded with Different Human Subjects at 64 and 128 MHz.

Authors:  W Liu; C M Collins; M B Smith
Journal:  Appl Magn Reson       Date:  2005-03       Impact factor: 0.831

5.  Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects.

Authors:  Christopher M Collins; Zhangwei Wang
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

6.  Image-guided radio-frequency gain calibration for high-field MRI.

Authors:  Elodie Breton; Kellyanne McGorty; Graham C Wiggins; Leon Axel; Daniel Kim
Journal:  NMR Biomed       Date:  2009-12-15       Impact factor: 4.044

Review 7.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

8.  Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T.

Authors:  Daniel Kim; Niels Oesingmann; Kellyanne McGorty
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

9.  Myocardial T2 quantitation in patients with iron overload at 3 Tesla.

Authors:  Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

10.  Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T.

Authors:  Michael Schär; Evert-Jan Vonken; Matthias Stuber
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.