Spatial localization in NMR spectroscopy in vivo.

P A Bottomley1.   

Abstract

Spatial localization techniques are necessary for in vivo NMR spectroscopy involving heterogeneous organisms. Localization by surface coil NMR detection alone is generally inadequate for deep-lying organs due to contaminating signals from intervening surface tissues. However, localization to preselected planar volumes can be accomplished using a single selective excitation pulse in the presence of a pulsed magnetic field gradient, yielding depth-resolved surface coil spectra (DRESS). Within selected planes, DRESS are spatially restricted by the surface coil sensitivity profiles to disk-shaped volumes whose radii increase with depth, notwithstanding variations in the NMR signal density distribution. Nevertheless, DRESS is a simple and versatile localization procedure that is readily adaptable to spectral relaxation time measurements by adding inversion or spin-echo refocusing pulses or to in vivo solvent-suppressed spectroscopy of proton (1H) metabolites using a combination of chemical-selective RF pulses. Also, the spatial information gathering efficiency of the technique can be improved to provide simultaneous acquisition of spectra from multiple volumes by interleaving excitation of adjacent planes within the normal relaxation recovery period. The spatial selectivity can be improved by adding additional selective excitation spin-echo refocusing pulses to achieve full, three-dimensional point resolved spectroscopy (PRESS) in a single excitation sequence. Alternatively, for samples with short spin-spin relaxation times, DRESS can be combined with other localization schemes, such as image-selected in vivo spectroscopy (ISIS), to provide complete gradient controlled three-dimensional localization with a reduced number of sequence cycles.

Entities:  

Mesh:

Year:  1987        PMID: 3326459     DOI: 10.1111/j.1749-6632.1987.tb32915.x

Source DB:  PubMed          Journal:  Ann N Y Acad Sci        ISSN: 0077-8923            Impact factor:   5.691


  368 in total

1.  Improving the detection of low concentration metabolites in magnetic resonance spectroscopy by digital filtering.

Authors:  L Lemaire; F Franconi; J J Lejeune; P Jallet; P Richomme
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  Coupling between changes in human brain temperature and oxidative metabolism during prolonged visual stimulation.

Authors:  D A Yablonskiy; J J Ackerman; M E Raichle
Journal:  Proc Natl Acad Sci U S A       Date:  2000-06-20       Impact factor: 11.205

3.  Multivoxel 3D proton spectroscopy in the brain at 1.5 versus 3.0 T: signal-to-noise ratio and resolution comparison.

Authors:  O Gonen; S Gruber; B S Li; V Mlynárik; E Moser
Journal:  AJNR Am J Neuroradiol       Date:  2001-10       Impact factor: 3.825

4.  Influence of EEG electrodes on the BOLD fMRI signal.

Authors:  G Bonmassar; N Hadjikhani; J R Ives; D Hinton; J W Belliveau
Journal:  Hum Brain Mapp       Date:  2001-10       Impact factor: 5.038

5.  Three-dimensional proton MR spectroscopic imaging of premature and term neonates.

Authors:  D B Vigneron; A J Barkovich; S M Noworolski; M von dem Bussche; R G Henry; Y Lu; J C Partridge; G Gregory; D M Ferriero
Journal:  AJNR Am J Neuroradiol       Date:  2001-08       Impact factor: 3.825

6.  Ethanol in human brain by magnetic resonance spectroscopy: correlation with blood and breath levels, relaxation, and magnetization transfer.

Authors:  G Fein; D J Meyerhoff
Journal:  Alcohol Clin Exp Res       Date:  2000-08       Impact factor: 3.455

7.  NMR separation of intra- and extracellular compounds based on intermolecular coherences.

Authors:  Verena Hoerr; Armin Purea; Cornelius Faber
Journal:  Biophys J       Date:  2010-10-06       Impact factor: 4.033

Review 8.  Three-dimensional magnetic resonance spectroscopic imaging of brain and prostate cancer.

Authors:  J Kurhanewicz; D B Vigneron; S J Nelson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

9.  Free-breathing inner-volume black-blood imaging of the human heart using two-dimensionally selective local excitation at 3 T.

Authors:  Khaled Z Abd-Elmoniem; Christoph Barmet; Matthias Stuber
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

10.  Biochemical abnormalities of the medial temporal lobe and medial prefrontal cortex in late-life depression.

Authors:  Talaignair N Venkatraman; Ranga R Krishnan; David C Steffens; Allen W Song; Warren D Taylor
Journal:  Psychiatry Res       Date:  2009-04-30       Impact factor: 3.222

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.