PURPOSE: To enable rapid imaging with a scan time-efficient 3D cones trajectory with a deep-learning off-resonance artifact correction technique. METHODS: A residual convolutional neural network to correct off-resonance artifacts (Off-ResNet) was trained with a prospective study of pediatric MRA exams. Each exam acquired a short readout scan (1.18 ms ± 0.38) and a long readout scan (3.35 ms ± 0.74) at 3 T. Short readout scans, with longer scan times but negligible off-resonance blurring, were used as reference images and augmented with additional off-resonance for supervised training examples. Long readout scans, with greater off-resonance artifacts but shorter scan time, were corrected by autofocus and Off-ResNet and compared with short readout scans by normalized RMS error, structural similarity index, and peak SNR. Scans were also compared by scoring on 8 anatomical features by two radiologists, using analysis of variance with post hoc Tukey's test and two one-sided t-tests. Reader agreement was determined with intraclass correlation. RESULTS: The total scan time for long readout scans was on average 59.3% shorter than short readout scans. Images from Off-ResNet had superior normalized RMS error, structural similarity index, and peak SNR compared with uncorrected images across ±1 kHz off-resonance (P < .01). The proposed method had superior normalized RMS error over -677 Hz to +1 kHz and superior structural similarity index and peak SNR over ±1 kHz compared with autofocus (P < .01). Radiologic scoring demonstrated that long readout scans corrected with Off-ResNet were noninferior to short readout scans (P < .05). CONCLUSION: The proposed method can correct off-resonance artifacts from rapid long-readout 3D cones scans to a noninferior image quality compared with diagnostically standard short readout scans.
PURPOSE: To enable rapid imaging with a scan time-efficient 3D cones trajectory with a deep-learning off-resonance artifact correction technique. METHODS: A residual convolutional neural network to correct off-resonance artifacts (Off-ResNet) was trained with a prospective study of pediatric MRA exams. Each exam acquired a short readout scan (1.18 ms ± 0.38) and a long readout scan (3.35 ms ± 0.74) at 3 T. Short readout scans, with longer scan times but negligible off-resonance blurring, were used as reference images and augmented with additional off-resonance for supervised training examples. Long readout scans, with greater off-resonance artifacts but shorter scan time, were corrected by autofocus and Off-ResNet and compared with short readout scans by normalized RMS error, structural similarity index, and peak SNR. Scans were also compared by scoring on 8 anatomical features by two radiologists, using analysis of variance with post hoc Tukey's test and two one-sided t-tests. Reader agreement was determined with intraclass correlation. RESULTS: The total scan time for long readout scans was on average 59.3% shorter than short readout scans. Images from Off-ResNet had superior normalized RMS error, structural similarity index, and peak SNR compared with uncorrected images across ±1 kHz off-resonance (P < .01). The proposed method had superior normalized RMS error over -677 Hz to +1 kHz and superior structural similarity index and peak SNR over ±1 kHz compared with autofocus (P < .01). Radiologic scoring demonstrated that long readout scans corrected with Off-ResNet were noninferior to short readout scans (P < .05). CONCLUSION: The proposed method can correct off-resonance artifacts from rapid long-readout 3D cones scans to a noninferior image quality compared with diagnostically standard short readout scans.
Authors: James G Pipe; Nicholas R Zwart; Eric A Aboussouan; Ryan K Robison; Ajit Devaraj; Kenneth O Johnson Journal: Magn Reson Med Date: 2011-04-05 Impact factor: 4.668
Authors: Kerstin Hammernik; Teresa Klatzer; Erich Kobler; Michael P Recht; Daniel K Sodickson; Thomas Pock; Florian Knoll Journal: Magn Reson Med Date: 2017-11-08 Impact factor: 4.668
Authors: Youngwook Kee; Christopher M Sandino; Ali B Syed; Joseph Y Cheng; Ann Shimakawa; Timothy J Colgan; Diego Hernando; Shreyas S Vasanawala Journal: Magn Reson Med Date: 2021-01-11 Impact factor: 4.668
Authors: Akshay S Chaudhari; Christopher M Sandino; Elizabeth K Cole; David B Larson; Garry E Gold; Shreyas S Vasanawala; Matthew P Lungren; Brian A Hargreaves; Curtis P Langlotz Journal: J Magn Reson Imaging Date: 2020-08-24 Impact factor: 5.119
Authors: Ryan L Brunsing; Kathryn J Fowler; Takeshi Yokoo; Guilherme Moura Cunha; Claude B Sirlin; Robert M Marks Journal: Hepatoma Res Date: 2020-09-01