Literature DB >> 8622590

Imaging of the active B1 field in vivo.

R Stollberger1, P Wach.   

Abstract

The authors describe a method for accurate in vivo multislice imaging of the active component of the B1 field which is based on a previously proposed method, which uses the signal intensity ratio of two images measured with different excitation angles, and a repetition time TR 5 > or = 5 T1. The new method essentially reduces repetition and scan time by means of an additional compensating pulse. The suppression of T1 effects by this pulse are verified with simulations and measurements. Further investigations concerned the influence of slice selective excitation and magnetization transfer in multislice imaging to the B1 field determination. The stability and accuracy of the presented method is shown by several phantom and in vivo measurements. With the described method the active B1 field can be determined in vivo in 23 cross-sections in less than 6 min.

Mesh:

Year:  1996        PMID: 8622590     DOI: 10.1002/mrm.1910350217

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  88 in total

1.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

2.  Self-refocused adiabatic pulse for spin echo imaging at 7 T.

Authors:  Priti Balchandani; Mohammad Mehdi Khalighi; Gary Glover; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

3.  Measuring B1 distributions by B1 phase encoding.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2016-01-17       Impact factor: 4.668

4.  Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Authors:  Ya-Jun Ma; Xing Lu; Michael Carl; Yanchun Zhu; Nikolaus M Szeverenyi; Graeme M Bydder; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

5.  Practical considerations for the design of sparse-spokes pulses.

Authors:  Marcin Jankiewicz; Huairen Zeng; Jason E Moore; Adam W Anderson; Malcolm J Avison; E Brian Welch; John C Gore
Journal:  J Magn Reson       Date:  2010-02-04       Impact factor: 2.229

6.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

7.  Direct magnetic resonance imaging of histological tissue samples at 3.0T.

Authors:  Mark D Meadowcroft; Shutong Zhang; Wanzhan Liu; Bu Sik Park; James R Connor; Christopher M Collins; Michael B Smith; Qing X Yang
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

8.  Four-dimensional transcatheter intraarterial perfusion (TRIP)-MRI for monitoring liver tumor embolization in VX2 rabbits.

Authors:  Dingxin Wang; Sumeet Virmani; Richard Tang; Barbara Szolc-Kowalska; Gayle Woloschak; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

9.  Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner.

Authors:  Phillip Zhe Sun; Thomas Benner; Ashok Kumar; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  Correlation between conductivity and prognostic factors in invasive breast cancer using magnetic resonance electric properties tomography (MREPT).

Authors:  Soo-Yeon Kim; Jaewook Shin; Dong-Hyun Kim; Min Jung Kim; Eun-Kyung Kim; Hee Jung Moon; Jung Hyun Yoon
Journal:  Eur Radiol       Date:  2015-10-23       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.