Literature DB >> 12704761

Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency.

Vibhas S Deshpande1, Steven M Shea, Debiao Li.   

Abstract

The presence of resonance frequency offsets often causes artifacts in images acquired with true fast imaging with steady-state precession (true-FISP). One source of resonance offsets is a suboptimal setting of the synthesizer frequency. The goal of this work was to demonstrate that shifting the synthesizer frequency could minimize the off-resonance related image artifacts in true-FISP. A simple scouting method was developed to estimate the optimal synthesizer frequency for the volume of interest (VOI). To improve fat suppression, a similar scouting method was also developed to determine the optimal frequency offset for the fat saturation pulse. Coronary artery imaging was performed in healthy subjects using a 3D true-FISP sequence to validate the effectiveness of the frequency corrections. Substantial reduction in image artifacts and improvement in fat suppression were observed by using the water and fat frequencies estimated by the scouting scans. Frequency shifting is a useful and practical method for improving coronary artery imaging using true-FISP. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12704761     DOI: 10.1002/mrm.10442

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  [MRI for therapy control in patients with aortic isthmus stenosis].

Authors:  B J Wintersperger; D Theisen; M F Reiser
Journal:  Radiologe       Date:  2011-01       Impact factor: 0.635

2.  Frequency scouting for cardiac imaging with SSFP at 3 Tesla.

Authors:  Janaka Wansapura; Robert Fleck; Eric Crotty; William Gottliebson
Journal:  Pediatr Radiol       Date:  2006-07-08

3.  Improved shim method based on the minimization of the maximum off-resonance frequency for balanced steady-state free precession (bSSFP).

Authors:  Jongho Lee; Michael Lustig; Dong-hyun Kim; John M Pauly
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

Review 4.  Low-Field Cardiac Magnetic Resonance Imaging: A Compelling Case for Cardiac Magnetic Resonance's Future.

Authors:  Orlando P Simonetti; Rizwan Ahmad
Journal:  Circ Cardiovasc Imaging       Date:  2017-06       Impact factor: 7.792

Review 5.  Evaluation of left ventricular function using cardiac magnetic resonance imaging.

Authors:  Suchi Grover; Darryl P Leong; Joseph B Selvanayagam
Journal:  J Nucl Cardiol       Date:  2011-04       Impact factor: 5.952

6.  Improved coronary MR angiography using wideband steady state free precession at 3 tesla with sub-millimeter resolution.

Authors:  Hsu-Lei Lee; Ajit Shankaranarayanan; Gerald M Pohost; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

7.  Whole-heart coronary magnetic resonance angiography at 3.0T using short-TR steady-state free precession, vastly undersampled isotropic projection reconstruction.

Authors:  Jingsi Xie; Peng Lai; Himanshu Bhat; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

8.  Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging.

Authors:  Jaime S Robb; Chenxi Hu; Dana C Peters
Journal:  Magn Reson Med       Date:  2019-10-12       Impact factor: 4.668

9.  Clinical applications for cardiovascular magnetic resonance imaging at 3 tesla.

Authors:  Allison G Hays; Michael Schär; Sebastian Kelle
Journal:  Curr Cardiol Rev       Date:  2009-08

10.  Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T.

Authors:  Michael Schär; Evert-Jan Vonken; Matthias Stuber
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.