Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout.

Sohae Chung1, Daniel Kim, Elodie Breton, Leon Axel.   

Abstract

In MRI, the transmit radiofrequency field (B(1)(+)) inhomogeneity can lead to signal intensity variations and quantitative measurement errors. By independently mapping the local B(1)(+) variation, the radiofrequency-related signal variations can be corrected for. In this study, we present a new fast B(1)(+) mapping method using a slice-selective preconditioning radiofrequency pulse. Immediately after applying a slice-selective preconditioning pulse, a turbo fast low-angle-shot imaging sequence with centric k-space reordering is performed to capture the residual longitudinal magnetization left behind by the slice-selective preconditioning pulse due to B(1)(+) variation. Compared to the reference double-angle method, this method is considerably faster. Specifically, the total scan time for the double-angle method is equal to the product of 2 (number of images), the number of phase-encoding lines, and approximately 5T(1), whereas the slice-selective preconditioning method takes approximately 5T(1). This method was validated in vitro and in vivo with a 3-T whole-body MRI system. The combined brain and pelvis B(1)(+) measurements showed excellent agreement and strong correlation with those by the double-angle method (mean difference = 0.025; upper and lower 95% limits of agreement were -0.07 and 0.12; R = 0.93; P < 0.001). This fast B(1)(+) mapping method can be used for a variety of applications, including body imaging where fast imaging is desirable.

Entities:  

Mesh:

Year:  2010        PMID: 20665788      PMCID: PMC2929762          DOI: 10.1002/mrm.22423

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Human cardiac imaging at 3 T using phased array coils.

Authors:  R Noeske; F Seifert; K H Rhein; H Rinneberg
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

2.  Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging.

Authors:  M S Cohen; R M DuBois; M M Zeineh
Journal:  Hum Brain Mapp       Date:  2000-08       Impact factor: 5.038

3.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

4.  Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan.

Authors:  G W Miller; T A Altes; J R Brookeman; E E De Lange; J P Mugler
Journal:  MAGMA       Date:  2004-03-23       Impact factor: 2.310

5.  Mapping of the radio frequency magnetic field with a MR snapshot FLASH technique.

Authors:  U Klose
Journal:  Med Phys       Date:  1992 Jul-Aug       Impact factor: 4.071

6.  MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results.

Authors:  Cedric M J de Bazelaire; Guillaume D Duhamel; Neil M Rofsky; David C Alsop
Journal:  Radiology       Date:  2004-03       Impact factor: 11.105

7.  Simulation of B1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field.

Authors:  R W Singerman; T J Denison; H Wen; R S Balaban
Journal:  J Magn Reson       Date:  1997-03       Impact factor: 2.229

8.  Radio frequency field intensity mapping using a composite spin-echo sequence.

Authors:  C H Oh; S K Hilal; Z H Cho; I K Mun
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

9.  Chemical shift artifact in clinical magnetic resonance images at 0.35 T.

Authors:  J C Weinreb; L Brateman; E E Babcock; K R Maravilla; J M Cohen; S D Horner
Journal:  AJR Am J Roentgenol       Date:  1985-07       Impact factor: 3.959

10.  Improving image quality and T(1) measurements using saturation recovery turboFLASH with an approximate K-space normalisation filter.

Authors:  G J Parker; I Baustert; S F Tanner; M O Leach
Journal:  Magn Reson Imaging       Date:  2000-02       Impact factor: 2.546

View more
  67 in total

1.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

2.  Lowering the B1 threshold for improved BEAR B1 mapping.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

3.  Modification of population based arterial input function to incorporate individual variation.

Authors:  Harrison Kim
Journal:  Magn Reson Imaging       Date:  2017-09-27       Impact factor: 2.546

4.  Radiofrequency transmit calibration: A multi-center evaluation of vendor-provided radiofrequency transmit mapping methods.

Authors:  Yannick Bliesener; Xinran Zhong; Yi Guo; Michael Boss; Ryan Bosca; Hendrik Laue; Caroline Chung; Kyunghyun Sung; Krishna S Nayak
Journal:  Med Phys       Date:  2019-04-15       Impact factor: 4.071

5.  Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator.

Authors:  KyungPyo Hong; Eun-Kee Jeong; T Scott Wall; Stavros G Drakos; Daniel Kim
Journal:  Magn Reson Med       Date:  2015-05-14       Impact factor: 4.668

6.  An in vivo comparison of the DREAM sequence with current RF shim technology.

Authors:  Kay Nehrke; Alois M Sprinkart; Peter Börnert
Journal:  MAGMA       Date:  2014-08-10       Impact factor: 2.310

7.  Pulsed arterial spin labelling at ultra-high field with a B 1 (+) -optimised adiabatic labelling pulse.

Authors:  Fabian Zimmer; Kieran O'Brien; Steffen Bollmann; Josef Pfeuffer; Keith Heberlein; Markus Barth
Journal:  MAGMA       Date:  2016-04-15       Impact factor: 2.310

8.  Optimized quantification of spin relaxation times in the hybrid state.

Authors:  Jakob Assländer; Riccardo Lattanzi; Daniel K Sodickson; Martijn A Cloos
Journal:  Magn Reson Med       Date:  2019-06-12       Impact factor: 4.668

9.  Portable perfusion phantom for quantitative DCE-MRI of the abdomen.

Authors:  Harrison Kim; Mina Mousa; Patrick Schexnailder; Robert Hergenrother; Mark Bolding; Bernard Ntsikoussalabongui; Vinoy Thomas; Desiree E Morgan
Journal:  Med Phys       Date:  2017-08-12       Impact factor: 4.071

10.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.