Literature DB >> 20725934

Tailoring the flow sensitivity of fast spin-echo sequences for noncontrast peripheral MR angiography.

Pippa Storey1, Iliyana P Atanasova, Ruth P Lim, Jian Xu, Daniel Kim, Qun Chen, Vivian S Lee.   

Abstract

There has recently been renewed interest in noncontrast techniques for peripheral MR angiography following the discovery of an association between gadolinium-based contrast agents and nephrogenic systemic fibrosis in patients with renal insufficiency. The "fresh blood imaging" technique proposed by Miyazaki et al. involves the subtraction of two three-dimensional fast spin-echo image sets, one acquired in systole, when the arteries appear dark due to flow-related dephasing, and the other obtained in diastole, when the arteries are brighter. Our goal was to investigate how parameters of the fast spin-echo sequence influence its flow sensitivity, and how that in turn impacts the depiction of large and small arteries. Results from phantom experiments and human studies in the calf suggest that the flow sensitivity is governed largely by the flip angle of the radiofrequency refocusing pulses. The area of the spoiler gradients has a lesser effect, and at low flip angles the echo time plays a role. These parameters can be optimized to obtain good depiction of the calf arteries in healthy subjects. It remains to be seen whether they provide sufficient control over flow sensitivity to achieve diagnostic-quality images in other vascular beds and in the presence of pathology.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20725934      PMCID: PMC3057440          DOI: 10.1002/mrm.22510

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

2.  Peripheral MR angiography: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging.

Authors:  Mitsue Miyazaki; Hiroshi Takai; Satoshi Sugiura; Hirofumi Wada; Rie Kuwahara; Joji Urata
Journal:  Radiology       Date:  2003-04-17       Impact factor: 11.105

Review 3.  Nonenhanced MR angiography.

Authors:  Mitsue Miyazaki; Vivian S Lee
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

4.  Factors predicting the diameter of the popliteal artery in healthy humans.

Authors:  T Sandgren; B Sonesson; A R Ahlgren; T Länne
Journal:  J Vasc Surg       Date:  1998-08       Impact factor: 4.268

5.  The sensitivity of low flip angle RARE imaging.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-02       Impact factor: 4.668

6.  Gradient moment nulling in fast spin echo.

Authors:  R S Hinks; R T Constable
Journal:  Magn Reson Med       Date:  1994-12       Impact factor: 4.668

Review 7.  Magnetic resonance angiography for the evaluation of lower extremity arterial disease: a meta-analysis.

Authors:  M J Koelemay; J G Lijmer; J Stoker; D A Legemate; P M Bossuyt
Journal:  JAMA       Date:  2001-03-14       Impact factor: 56.272

8.  Image-guided radio-frequency gain calibration for high-field MRI.

Authors:  Elodie Breton; Kellyanne McGorty; Graham C Wiggins; Leon Axel; Daniel Kim
Journal:  NMR Biomed       Date:  2009-12-15       Impact factor: 4.044

9.  Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo.

Authors:  Reed F Busse; Anja C S Brau; Anthony Vu; Charles R Michelich; Ersin Bayram; Richard Kijowski; Scott B Reeder; Howard A Rowley
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

Review 10.  Gadolinium and nephrogenic systemic fibrosis.

Authors:  T Grobner; F C Prischl
Journal:  Kidney Int       Date:  2007-05-16       Impact factor: 10.612

View more
  25 in total

1.  Nonenhanced methods for lower-extremity MRA: a phantom study examining the effects of stenosis and pathologic flow waveforms at 1.5T.

Authors:  Erik J Offerman; Philip A Hodnett; Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Optimization of 3D-variable refocusing flip angle RARE imaging for high-resolution volumetric black-blood angiography.

Authors:  Masami Yoneyama; Masanobu Nakamura; Takashi Tabuchi; Atsushi Takemura; Makoto Obara
Journal:  Radiol Phys Technol       Date:  2012-06-20

3.  Arterial flow characteristics in the presence of vascular disease and implications for fast spin echo-based noncontrast MR angiography.

Authors:  Pippa Storey; Ruth P Lim; Sooah Kim; David R Stoffel; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2011-09-29       Impact factor: 4.813

4.  Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA.

Authors:  Gesine Knobloch; Marie-Teres Lauff; Sebastian Hirsch; Carsten Schwenke; Bernd Hamm; Moritz Wagner
Journal:  Eur Radiol       Date:  2016-02-10       Impact factor: 5.315

5.  Simple method for whole-brain volumetric T(1)-weighted turbo spin-echo imaging.

Authors:  Masami Yoneyama; Masanobu Nakamura; Makoto Obara; Takashi Namiki; Atsushi Takemura; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-12-04

6.  Controlling T2 blurring in 3D RARE arterial spin labeling acquisition through optimal combination of variable flip angles and k-space filtering.

Authors:  Li Zhao; Ching-Di Chang; David C Alsop
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

7.  Velocity-selective magnetization-prepared non-contrast-enhanced cerebral MR angiography at 3 Tesla: Improved immunity to B0/B1 inhomogeneity.

Authors:  Qin Qin; Taehoon Shin; Michael Schär; Hua Guo; Hanwei Chen; Ye Qiao
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

8.  Comparison of nonenhanced MR angiographic subtraction techniques for infragenual arteries at 1.5 T: a preliminary study.

Authors:  Ruth P Lim; Zhaoyang Fan; Manjil Chatterji; Amanjit Baadh; Iliyana P Atanasova; Pippa Storey; Danny C Kim; Sooah Kim; Philip A Hodnett; Afhsan Ahmad; David R Stoffel; James S Babb; Mark A Adelman; Jian Xu; Debiao Li; Vivian S Lee
Journal:  Radiology       Date:  2013-01-07       Impact factor: 11.105

9.  Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition.

Authors:  Weitian Chen; Queenie Chan; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-04

10.  Hyperintense Vessels on T2-PROPELLER-FLAIR in Patients with Acute MCA Stroke: Prediction of Arterial Stenosis and Perfusion Abnormality.

Authors:  S J Ahn; S H Suh; K-Y Lee; J H Kim; K-D Seo; S Lee
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-30       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.