Literature DB >> 26375209

A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Ryan Brown1, Karthik Lakshmanan2, Guillaume Madelin2, Prodromos Parasoglou2.   

Abstract

A dual-nuclei radiofrequency coil array was constructed for phosphorus and proton magnetic resonance imaging and spectroscopy of the human brain at 7T. An eight-channel transceive degenerate birdcage phosphorus module was implemented to provide whole-brain coverage and significant sensitivity improvement over a standard dual-tuned loop coil. A nested eight-channel proton module provided adequate sensitivity for anatomical localization without substantially sacrificing performance on the phosphorus module. The developed array enabled phosphorus spectroscopy, a saturation transfer technique to calculate the global creatine kinase forward reaction rate, and single-metabolite whole-brain imaging with 1.4cm nominal isotropic resolution in 15min (2.3cm actual resolution), while additionally enabling 1mm isotropic proton imaging. This study demonstrates that a multi-channel array can be utilized for phosphorus and proton applications with improved coverage and/or sensitivity over traditional single-channel coils. The efficient multi-channel coil array, time-efficient pulse sequences, and the enhanced signal strength available at ultra-high fields can be combined to allow volumetric assessment of the brain and could provide new insights into the underlying energy metabolism impairment in several neurodegenerative conditions, such as Alzheimer's and Parkinson's diseases, as well as mental disorders such as schizophrenia.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Creatine kinase reaction; Degenerate birdcage; Dual-tuned coil; FLORET pulse sequence; Transceive phased array

Mesh:

Substances:

Year:  2015        PMID: 26375209      PMCID: PMC4651763          DOI: 10.1016/j.neuroimage.2015.08.066

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  68 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Metabolic mapping using 2D 31P-MR spectroscopy reveals frontal and thalamic metabolic abnormalities in schizophrenia.

Authors:  Stefan Smesny; Timm Rosburg; Igor Nenadic; Klaus Peter Fenk; Sebastian Kunstmann; Reinhardt Rzanny; Hans-Peter Volz; Heinrich Sauer
Journal:  Neuroimage       Date:  2006-12-29       Impact factor: 6.556

3.  A new design and rationale for 3D orthogonally oversampled k-space trajectories.

Authors:  James G Pipe; Nicholas R Zwart; Eric A Aboussouan; Ryan K Robison; Ajit Devaraj; Kenneth O Johnson
Journal:  Magn Reson Med       Date:  2011-04-05       Impact factor: 4.668

4.  High-resolution quantitative sodium imaging at 9.4 Tesla.

Authors:  Christian C Mirkes; Jens Hoffmann; G Shajan; Rolf Pohmann; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

5.  Clinically constrained optimization of flexTPI acquisition parameters for the tissue sodium concentration bioscale.

Authors:  Ian C Atkinson; Aiming Lu; Keith R Thulborn
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

6.  Double resonant quadrature birdcage.

Authors:  J R Fitzsimmons; B L Beck; H R Brooker
Journal:  Magn Reson Med       Date:  1993-07       Impact factor: 4.668

Review 7.  NMR studies of enzymatic rates in vitro and in vivo by magnetization transfer.

Authors:  J R Alger; R G Shulman
Journal:  Q Rev Biophys       Date:  1984-02       Impact factor: 5.318

8.  Double-tuned four-ring birdcage resonators for in vivo 31P-nuclear magnetic resonance spectroscopy at 11.75 T.

Authors:  T Lanz; M von Kienlin; W Behr; A Haase
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

9.  Dynamic three-dimensional imaging of phosphocreatine recovery kinetics in the human lower leg muscles at 3T and 7T: a preliminary study.

Authors:  Prodromos Parasoglou; Ding Xia; Gregory Chang; Ravinder R Regatte
Journal:  NMR Biomed       Date:  2012-10-13       Impact factor: 4.044

10.  Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging.

Authors:  Ryan Brown; Guillaume Madelin; Riccardo Lattanzi; Gregory Chang; Ravinder R Regatte; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2012-08-08       Impact factor: 4.668

View more
  4 in total

1.  An eight-channel sodium/proton coil for brain MRI at 3 T.

Authors:  Karthik Lakshmanan; Ryan Brown; Guillaume Madelin; Yongxian Qian; Fernando Boada; Graham C Wiggins
Journal:  NMR Biomed       Date:  2017-12-27       Impact factor: 4.044

2.  (31)P CSI of the human brain in healthy subjects and tumor patients at 9.4 T with a three-layered multi-nuclear coil: initial results.

Authors:  Christian Mirkes; Gunamony Shajan; Grzegorz Chadzynski; Kai Buckenmaier; Benjamin Bender; Klaus Scheffler
Journal:  MAGMA       Date:  2016-01-25       Impact factor: 2.310

3.  A radially interleaved sodium and proton coil array for brain MRI at 7 T.

Authors:  Bili Wang; Bei Zhang; Zidan Yu; Carlotta Ianniello; Karthik Lakshmanan; Jan Paska; Guillaume Madelin; Martijn Cloos; Ryan Brown
Journal:  NMR Biomed       Date:  2021-09-03       Impact factor: 4.478

4.  Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles using a Dual-Frequency Coil Array.

Authors:  Ryan Brown; Oleksandr Khegai; Prodromos Parasoglou
Journal:  Sci Rep       Date:  2016-07-28       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.