Literature DB >> 24056112

Design and application of combined 8-channel transmit and 10-channel receive arrays and radiofrequency shimming for 7-T shoulder magnetic resonance imaging.

Ryan Brown1, Cem Murat Deniz, Bei Zhang, Gregory Chang, Daniel K Sodickson, Graham C Wiggins.   

Abstract

OBJECTIVE: The objective of the study was to investigate the feasibility of 7-T shoulder magnetic resonance imaging by developing transmit and receive radiofrequency (RF) coil arrays and exploring RF shim methods.
MATERIALS AND METHODS: A mechanically flexible 8-channel transmit array and an anatomically conformable 10-channel receive array were designed and implemented. The transmit performance of various RF shim methods was assessed through local flip angle measurements in the right and left shoulders of 6 subjects. The receive performance was assessed through signal-to-noise ratio measurements using the developed 7-T coil and a baseline commercial 3-T coil.
RESULTS: The 7-T transmit array driven with phase-coherent RF shim weights provided adequate B₁⁺ efficiency and uniformity for turbo spin echo shoulder imaging. B₁⁺ twisting that is characteristic of high-field loop coils necessitates distinct RF shim weights in the right and left shoulders. The 7-T receive array provided a 2-fold signal-to-noise ratio improvement over the 3-T array in the deep articular shoulder cartilage.
CONCLUSIONS: Shoulder imaging at 7-T is feasible with a custom transmit/receive array either in a single-channel transmit mode with a fixed RF shim or in a parallel transmit mode with a subject-specific RF shim.

Entities:  

Mesh:

Year:  2014        PMID: 24056112      PMCID: PMC4036121          DOI: 10.1097/RLI.0b013e3182a5662d

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  36 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).

Authors:  Juergen Hennig; Matthias Weigel; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

3.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

4.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

5.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

6.  Central brightening due to constructive interference with, without, and despite dielectric resonance.

Authors:  Christopher M Collins; Wanzhan Liu; Weston Schreiber; Qing X Yang; Michael B Smith
Journal:  J Magn Reson Imaging       Date:  2005-02       Impact factor: 4.813

7.  B(1) destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil.

Authors:  Pierre-François Van de Moortele; Can Akgun; Gregor Adriany; Steen Moeller; Johannes Ritter; Christopher M Collins; Michael B Smith; J Thomas Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

8.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

9.  A precise and fast temperature mapping using water proton chemical shift.

Authors:  Y Ishihara; A Calderon; H Watanabe; K Okamoto; Y Suzuki; K Kuroda; Y Suzuki
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

10.  From complex B(1) mapping to local SAR estimation for human brain MR imaging using multi-channel transceiver coil at 7T.

Authors:  Xiaotong Zhang; Sebastian Schmitter; Pierre-Francois Van de Moortele; Jiaen Liu; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2013-03-11       Impact factor: 10.048

View more
  10 in total

1.  Sparse parallel transmission on randomly perturbed spiral k-space trajectory.

Authors:  Yong Pang; Xiaohua Jiang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-04

2.  Characterization of a dielectric phantom for high-field magnetic resonance imaging applications.

Authors:  Qi Duan; Jeff H Duyn; Natalia Gudino; Jacco A de Zwart; Peter van Gelderen; Daniel K Sodickson; Ryan Brown
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

3.  Electrodynamics and radiofrequency antenna concepts for human magnetic resonance at 23.5 T (1 GHz) and beyond.

Authors:  Lukas Winter; Thoralf Niendorf
Journal:  MAGMA       Date:  2016-04-20       Impact factor: 2.310

4.  An eight-channel sodium/proton coil for brain MRI at 3 T.

Authors:  Karthik Lakshmanan; Ryan Brown; Guillaume Madelin; Yongxian Qian; Fernando Boada; Graham C Wiggins
Journal:  NMR Biomed       Date:  2017-12-27       Impact factor: 4.044

5.  Dependence of B1+ and B1- Field Patterns of Surface Coils on the Electrical Properties of the Sample and the MR Operating Frequency.

Authors:  Manushka V Vaidya; Christopher M Collins; Daniel K Sodickson; Ryan Brown; Graham C Wiggins; Riccardo Lattanzi
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2016-02-04       Impact factor: 1.176

6.  A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Leeor Alon; Gregory Chang; Daniel K Sodickson; Ravinder R Regatte; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2015-10-26       Impact factor: 4.668

Review 7.  Parallel transmission for ultrahigh-field imaging.

Authors:  Francesco Padormo; Arian Beqiri; Joseph V Hajnal; Shaihan J Malik
Journal:  NMR Biomed       Date:  2015-05-19       Impact factor: 4.044

8.  A 32-channel parallel transmit system add-on for 7T MRI.

Authors:  Stephan Orzada; Klaus Solbach; Marcel Gratz; Sascha Brunheim; Thomas M Fiedler; Sören Johst; Andreas K Bitz; Samaneh Shooshtary; Ashraf Abuelhaija; Maximilian N Voelker; Stefan H G Rietsch; Oliver Kraff; Stefan Maderwald; Martina Flöser; Mark Oehmigen; Harald H Quick; Mark E Ladd
Journal:  PLoS One       Date:  2019-09-12       Impact factor: 3.240

9.  7-T clinical MRI of the shoulder in patients with suspected lesions of the rotator cuff.

Authors:  Andrea Lazik-Palm; Oliver Kraff; Stefan H G Rietsch; Mark E Ladd; Michael Kamminga; Sascha Beck; Harald H Quick; Jens M Theysohn
Journal:  Eur Radiol Exp       Date:  2020-02-07

10.  Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles using a Dual-Frequency Coil Array.

Authors:  Ryan Brown; Oleksandr Khegai; Prodromos Parasoglou
Journal:  Sci Rep       Date:  2016-07-28       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.