Literature DB >> 24123517

Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression.

Ryan Brown1, Pippa Storey, Christian Geppert, KellyAnne McGorty, Ana Paula Klautau Leite, James Babb, Daniel K Sodickson, Graham C Wiggins, Linda Moy.   

Abstract

PURPOSE: To develop a bilateral coil and fat suppressed T1-weighted sequence for 7 Tesla (T) breast MRI.
MATERIALS AND METHODS: A dual-solenoid coil and three-dimensional (3D) T1w gradient echo sequence with B1+ insensitive fat suppression (FS) were developed. T1w FS image quality was characterized through image uniformity and fat-water contrast measurements in 11 subjects. Signal-to-noise ratio (SNR) and flip angle maps were acquired to assess the coil performance. Bilateral contrast-enhanced and unilateral high resolution (0.6 mm isotropic, 6.5 min acquisition time) imaging highlighted the 7T SNR advantage.
RESULTS: Reliable and effective FS and high image quality was observed in all subjects at 7T, indicating that the custom coil and pulse sequence were insensitive to high-field obstacles such as variable tissue loading. 7T and 3T image uniformity was similar (P=0.24), indicating adequate 7T B1+ uniformity. High 7T SNR and fat-water contrast enabled 0.6 mm isotropic imaging and visualization of a high level of fibroglandular tissue detail.
CONCLUSION: 7T T1w FS bilateral breast imaging is feasible with a custom radiofrequency (RF) coil and pulse sequence. Similar image uniformity was achieved at 7T and 3T, despite different RF field behavior and variable coil-tissue interaction due to anatomic differences that might be expected to alter magnetic field patterns.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  RF coil; bilateral breast magnetic resonance imaging; breast cancer; fat suppression; high-field MRI

Mesh:

Substances:

Year:  2013        PMID: 24123517      PMCID: PMC3945054          DOI: 10.1002/jmri.24205

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  21 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

Authors:  Scott B Reeder; Zhifei Wen; Huanzhou Yu; Angel R Pineda; Garry E Gold; Michael Markl; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction.

Authors:  G H Glover; E Schneider
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

4.  Image reconstruction in SNR units: a general method for SNR measurement.

Authors:  Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

5.  Custom-fitted 16-channel bilateral breast coil for bidirectional parallel imaging.

Authors:  Anderson N Nnewihe; Thomas Grafendorfer; Bruce L Daniel; Paul Calderon; Marcus T Alley; Fraser Robb; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

6.  Effect of B1 inhomogeneity on breast MR imaging at 3.0 T.

Authors:  Christiane K Kuhl; Hendrik Kooijman; Juergen Gieseke; Hans H Schild
Journal:  Radiology       Date:  2007-09       Impact factor: 11.105

Review 7.  How much contrast is enough?. Dependence of enhancement on field strength and MR pulse sequence.

Authors:  A D Elster
Journal:  Eur Radiol       Date:  1997       Impact factor: 5.315

8.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues.

Authors:  S Gabriel; R W Lau; C Gabriel
Journal:  Phys Med Biol       Date:  1996-11       Impact factor: 3.609

9.  Global cancer statistics, 2002.

Authors:  D Max Parkin; Freddie Bray; J Ferlay; Paola Pisani
Journal:  CA Cancer J Clin       Date:  2005 Mar-Apr       Impact factor: 508.702

10.  Brain tumors: full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T--Initial Experience.

Authors:  Carsten Krautmacher; Winfried A Willinek; Henriette J Tschampa; Mark Born; Frank Träber; Jürgen Gieseke; Hans J Textor; Hans H Schild; Christiane K Kuhl
Journal:  Radiology       Date:  2005-10-19       Impact factor: 11.105

View more
  11 in total

1.  Experimental and numerical analysis of B1(+) field and SAR with a new transmit array design for 7T breast MRI.

Authors:  Junghwan Kim; Narayan Krishnamurthy; Tales Santini; Yujuan Zhao; Tiejun Zhao; Kyongtae Ty Bae; Tamer S Ibrahim
Journal:  J Magn Reson       Date:  2016-04-23       Impact factor: 2.229

2.  A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

Authors:  Romina Del Bosque; Jiaming Cui; Stephen Ogier; Sergey Cheshkov; Ivan E Dimitrov; Craig Malloy; Steven M Wright; Mary McDougall
Journal:  Magn Reson Med       Date:  2020-08-09       Impact factor: 4.668

3.  A dual-tuned multichannel bilateral RF coil for 1 H/23 Na breast MRI at 7 T.

Authors:  Carlotta Ianniello; Guillaume Madelin; Linda Moy; Ryan Brown
Journal:  Magn Reson Med       Date:  2019-05-31       Impact factor: 4.668

Review 4.  The potential of multiparametric MRI of the breast.

Authors:  Katja Pinker; Thomas H Helbich; Elizabeth A Morris
Journal:  Br J Radiol       Date:  2016-11-02       Impact factor: 3.039

5.  Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study.

Authors:  Gisela L G Menezes; Bertine L Stehouwer; Dennis W J Klomp; Tijl A van der Velden; Maurice A A J van den Bosch; Floortje M Knuttel; Vincent O Boer; Wybe J M van der Kemp; Peter R Luijten; Wouter B Veldhuis
Journal:  Springerplus       Date:  2016-01-05

6.  Development of a 7 T RF coil system for breast imaging.

Authors:  Junghwan Kim; Tales Santini; Kyongtae Ty Bae; Narayan Krishnamurthy; Yujuan Zhao; Tiejun Zhao; Tamer S Ibrahim
Journal:  NMR Biomed       Date:  2016-11-11       Impact factor: 4.044

Review 7.  Current and Emerging Magnetic Resonance-Based Techniques for Breast Cancer.

Authors:  Apekshya Chhetri; Xin Li; Joseph V Rispoli
Journal:  Front Med (Lausanne)       Date:  2020-05-12

8.  The Potential of High Resolution Magnetic Resonance Microscopy in the Pathologic Analysis of Resected Breast and Lymph Tissue.

Authors:  Brittany Z Dashevsky; Timothy D'Alfonso; Elizabeth J Sutton; Ashley Giambrone; Eric Aronowitz; Elizabeth A Morris; Krishna Juluru; Douglas J Ballon
Journal:  Sci Rep       Date:  2015-12-07       Impact factor: 4.379

9.  Transverse slot antennas for high field MRI.

Authors:  Leeor Alon; Riccardo Lattanzi; Karthik Lakshmanan; Ryan Brown; Cem M Deniz; Daniel K Sodickson; Christopher M Collins
Journal:  Magn Reson Med       Date:  2018-02-01       Impact factor: 4.668

10.  Homogeneous B1 + for bilateral breast imaging at 7 T using a five dipole transmit array merged with a high density receive loop array.

Authors:  Erwin Krikken; Bart R Steensma; Ingmar J Voogt; Peter R Luijten; Dennis W J Klomp; Alexander J E Raaijmakers; Jannie P Wijnen
Journal:  NMR Biomed       Date:  2018-11-29       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.