Literature DB >> 11287516

MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents.

L W Bartels1, H F Smits, C J Bakker, M A Viergever.   

Abstract

PURPOSE: The purpose of this in vitro study was to examine the various sources of artifacts in magnetic resonance (MR) imaging and angiography of vascular stents.
MATERIALS AND METHODS: Five low-artifact stents-Wallstent (cobalt alloy), Memotherm (nitinol), Perflex (stainless steel), Passager (tantalum), and Smart (nitinol)-were imaged in a vascular flow phantom, consisting of a thin-walled cellulose vessel model connected to a pump system. The echo time and the angulation of the stents with respect to the direction of the main magnetic field were varied. Spin echo and gradient echo images as well as three-dimensional MR angiograms were obtained to study the effects of flow, magnetic susceptibility, and radiofrequency-induced eddy currents.
RESULTS: Susceptibility artifacts were restricted to the stents' direct environment and were mildest at short echo times and with the stents aligned with the main magnetic field. Nitinol stents showed less artifacts than steel stents did. Radiofrequency artifacts obscuring the stent lumen and flow-related lumen displacement were seen in all stents. The extent to which these occurred depended on strut geometry and orientation.
CONCLUSIONS: For low-artifact stents, the material the stent is made of is not the only important factor in the process of artifact formation. Susceptibility artifacts, radiofrequency eddy currents and flow-related artifacts all contribute to the image distortion, and are dependent on the geometry and orientation of the struts and on the orientation of the stent in the main magnetic field.

Entities:  

Mesh:

Year:  2001        PMID: 11287516     DOI: 10.1016/s1051-0443(07)61918-6

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  24 in total

1.  MR-velocity mapping in vascular stents to assess peak systolic velocity. In vitro comparison of various stent designs made of Stainless Steel and Nitinol.

Authors:  Jacqueline van Holten; Patrik Kunz; Paul G H Mulder; Peter M T Pattynama; Hildo J Lamb; Lukas C van Dijk
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI.

Authors:  K Miyata; M Hasegawa; Y Abe; T Tabuchi; T Namiki; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

3.  Carotid artery stents: in vitro comparison of different stent designs and sizes using CT angiography and contrast-enhanced MR angiography at 1.5T and 3T.

Authors:  M Lettau; A Sauer; S Heiland; S Rohde; M Bendszus; S Hähnel
Journal:  AJNR Am J Neuroradiol       Date:  2009-09-12       Impact factor: 3.825

4.  Radiofrequency heating of metallic dental devices during 3.0 T MRI.

Authors:  M Hasegawa; K Miyata; Y Abe; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

5.  Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms.

Authors:  Y J Heo; H W Jeong; J W Baek; S T Kim; Y G Jeong; J Y Lee; S-C Jin
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

6.  Comparison of nonenhanced MR angiographic subtraction techniques for infragenual arteries at 1.5 T: a preliminary study.

Authors:  Ruth P Lim; Zhaoyang Fan; Manjil Chatterji; Amanjit Baadh; Iliyana P Atanasova; Pippa Storey; Danny C Kim; Sooah Kim; Philip A Hodnett; Afhsan Ahmad; David R Stoffel; James S Babb; Mark A Adelman; Jian Xu; Debiao Li; Vivian S Lee
Journal:  Radiology       Date:  2013-01-07       Impact factor: 11.105

7.  Postoperative 3D angiography in intracranial aneurysms.

Authors:  Hyun-Seung Kang; Moon Hee Han; Bae Ju Kwon; Sung Il Jung; Chang-Wan Oh; Dae Hee Han; Kee-Hyun Chang
Journal:  AJNR Am J Neuroradiol       Date:  2004-10       Impact factor: 3.825

Review 8.  An overview on the advances in cardiovascular interventional MR imaging.

Authors:  Olaf Saborowski; Maythem Saeed
Journal:  MAGMA       Date:  2007-05-09       Impact factor: 2.310

9.  In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T.

Authors:  Michael Lettau; Annett Sauer; Sabine Heiland; Stefan Rohde; Julia Reinhardt; Martin Bendszus; Stefan Hähnel
Journal:  Neuroradiology       Date:  2009-11-19       Impact factor: 2.804

10.  Successful nitinol stent implantation in a large coronary aneurysm: post-interventional patency assessment by magnetic resonance imaging.

Authors:  Frank Breuckmann; Kai Nassenstein; Dirk Boese; Dieter Opherk; Harald H Quick; Jörg Barkhausen; Raimund Erbel
Journal:  Int J Cardiovasc Imaging       Date:  2006-03-04       Impact factor: 2.357

View more