Literature DB >> 27535040

Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions: an in vitro comparison study.

Gitsios Gitsioudis1, Philipp Fortner2, Matthias Stuber3,4, Anna Missiou2, Florian Andre2, Oliver J Müller2, Hugo A Katus2, Grigorios Korosoglou2.   

Abstract

To compare the value of inversion recovery with on-resonant water suppression (IRON) to conventional T1-weighted (T1w) MRA and computed tomography angiography (CTA) for visualization of peripheral nitinol stents. We visualized 14 different peripheral nitinol stents in vitro both using Gadolinium (Gd) and ultrasmall superparamagnetic iron nanoparticles (USPIOs) for conventional T1w and IRON-MRA using clinical grade 1.5T MR scanner and iodinated contrast material for CTA using a 256-slice CT scanner. Parameter assessment included signal- and contrast-to-noise ratio (S/CNR), relative in-stent signal and artificial lumen narrowing. X-ray angiography served as gold standard for diameter assessment. Gd-enhanced IRON-MRA exhibited highest in-stent SNR and CNR values compared to conventional T1w MRA (IRON (Gd/USPIO): SNR = 30 ± 3/21 ± 2, CNR = 23 ± 2/14 ± 1; T1w: SNR = 16 ± 1/14 ± 2, CNR = 12 ± 1/10 ± 1, all p < 0.05). Furthermore, IRON-MRA achieved highest relative in-stent signal both using Gd and USPIO (IRON (Gd/USPIO): 121 ± 8 %/103 ± 6 %; T1w: 73 ± 2 %/66 ± 4 %; CTA: 84 ± 6 %, all p < 0.05). However, artificial lumen narrowing appeared similar in all imaging protocols (IRON (Gd/USPIO): 21 ± 3 %/21 ± 2 %; T1w: 16 ± 4 %/17 ± 3 %; CTA: 19 ± 2 %, all p = NS). Finally, IRON-MRA provided improvement of the in-stent lumen visualization with an 'open-close-open' design, which revealed a complete in-stent signal loss in T1w MRA. IRON-MRA improves in-stent visualization in vitro compared to conventional T1w MRA and CTA. In light of the in vitro results with Gd-enhanced IRON-MRA, the clinical implementation of such an approach appears promising.

Entities:  

Keywords:  Computed tomography angiography (CTA); Inversion recovery with on-resonant water suppression (IRON); Magnetic resonance angiography (MRA); Stent-related artifacts; T1-weighted MRA

Mesh:

Substances:

Year:  2016        PMID: 27535040     DOI: 10.1007/s10554-016-0955-4

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  40 in total

1.  In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT.

Authors:  Henning Steen; Florian André; Grigorios Korosoglou; Dirk Mueller; Waldemar Hosch; Hans-Ulrich Kauczor; Evangelos Giannitsis; Hugo A Katus
Journal:  Eur J Radiol       Date:  2010-09-03       Impact factor: 3.528

2.  Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II).

Authors:  L Norgren; W R Hiatt; J A Dormandy; M R Nehler; K A Harris; F G R Fowkes
Journal:  J Vasc Surg       Date:  2007-01       Impact factor: 4.268

3.  Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

Authors:  Matthias Stuber; Wesley D Gilson; Michael Schär; Dorota A Kedziorek; Lawrence V Hofmann; Saurabh Shah; Evert-Jan Vonken; Jeff W M Bulte; Dara L Kraitchman
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

4.  ESC Guidelines on the diagnosis and treatment of peripheral artery diseases: Document covering atherosclerotic disease of extracranial carotid and vertebral, mesenteric, renal, upper and lower extremity arteries: the Task Force on the Diagnosis and Treatment of Peripheral Artery Diseases of the European Society of Cardiology (ESC).

Authors:  Michal Tendera; Victor Aboyans; Marie-Louise Bartelink; Iris Baumgartner; Denis Clément; Jean-Philippe Collet; Alberto Cremonesi; Marco De Carlo; Raimund Erbel; F Gerry R Fowkes; Magda Heras; Serge Kownator; Erich Minar; Jan Ostergren; Don Poldermans; Vincent Riambau; Marco Roffi; Joachim Röther; Horst Sievert; Marc van Sambeek; Thomas Zeller
Journal:  Eur Heart J       Date:  2011-08-26       Impact factor: 29.983

5.  Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent.

Authors:  Alexander Radbruch; Lukas D Weberling; Pascal J Kieslich; Oliver Eidel; Sina Burth; Philipp Kickingereder; Sabine Heiland; Wolfgang Wick; Heinz-Peter Schlemmer; Martin Bendszus
Journal:  Radiology       Date:  2015-04-06       Impact factor: 11.105

6.  Gadolinium-based Contrast Agent Accumulates in the Brain Even in Subjects without Severe Renal Dysfunction: Evaluation of Autopsy Brain Specimens with Inductively Coupled Plasma Mass Spectroscopy.

Authors:  Tomonori Kanda; Toshio Fukusato; Megumi Matsuda; Keiko Toyoda; Hiroshi Oba; Jun'ichi Kotoku; Takahiro Haruyama; Kazuhiro Kitajima; Shigeru Furui
Journal:  Radiology       Date:  2015-05-05       Impact factor: 11.105

Review 7.  Hepatic MRI with SPIO: detection and characterization of focal liver lesions.

Authors:  P Reimer; B Tombach
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

8.  In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T.

Authors:  Michael Lettau; Annett Sauer; Sabine Heiland; Stefan Rohde; Julia Reinhardt; Martin Bendszus; Stefan Hähnel
Journal:  Neuroradiology       Date:  2009-11-19       Impact factor: 2.804

9.  Contrast-enhanced MR imaging of liver and spleen: first experience in humans with a new superparamagnetic iron oxide.

Authors:  B Hamm; T Staks; M Taupitz; R Maibauer; A Speidel; A Huppertz; T Frenzel; R Lawaczeck; K J Wolf; L Lange
Journal:  J Magn Reson Imaging       Date:  1994 Sep-Oct       Impact factor: 4.813

10.  Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate.

Authors:  Matthew S Davenport; Shokoufeh Khalatbari; Richard H Cohan; Jonathan R Dillman; James D Myles; James H Ellis
Journal:  Radiology       Date:  2013-04-11       Impact factor: 11.105

View more
  2 in total

1.  Positive visualization of MR-compatible nitinol stent using a susceptibility-based imaging technique.

Authors:  Caiyun Shi; Guoxi Xie; Dong Liang; Haifeng Wang; Yi Huang; Yanan Ren; Yong Xue; Hanwei Chen; Shi Su; Xin Liu
Journal:  Quant Imaging Med Surg       Date:  2019-03

2.  Cardiovascular imaging 2016 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Vande Veire
Journal:  Int J Cardiovasc Imaging       Date:  2017-06       Impact factor: 2.357

  2 in total