Literature DB >> 19904533

Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Alfonso Manzotti1, Pietro Cerveri, Elena De Momi, Chris Pullen, Norberto Confalonieri.   

Abstract

Leg length discrepancy following total hip replacement (THR) can contribute to poor hip function. Abnormal gait, pain, neurological disturbance and patient dissatisfaction have all been described as a result of leg length inequality after THR. The purpose of this study was to determine whether the use of computer navigation in THR can improve limb length restoration and early clinical outcomes. We performed a matched-pair study comparing 48 computer-assisted THR with 48 THRs performed using a traditional freehand alignment method. The same implant with a straight non-modular femoral stem was used in all cases. The navigation system used allowed the surgeon to monitor both acetabular cup placement and all the phases of femoral stem implantation including rasping. Patients were matched for age, sex, arthritis level, pre-operative diagnosis and pre-operative leg length discrepancy. At a minimum follow-up of six months, limb length discrepancy was measured using digital radiographs and a standardised protocol. The number of patients with a residual discrepancy of 10 mm or more and/or a post-operative over-lengthening were measured. The clinical outcome was evaluated using both the Harris Hip Score and the normalised Western Ontario and McMaster Universities (WOMAC) Arthritis Index. Restoration of limb length was significantly better in the computer-assisted THR group. The number of patients with a residual limb length discrepancy greater than 10 mm and/or a post-operative over-lengthening was significantly lower. No significant difference in the Harris Hip Score or normalised WOMAC Arthritis Index was seen between the two groups. The surgical time was significantly longer in the computer-assisted THR group. No post-operative dislocations were seen.

Entities:  

Mesh:

Year:  2009        PMID: 19904533      PMCID: PMC3014491          DOI: 10.1007/s00264-009-0903-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  34 in total

Review 1.  Dislocation after total hip arthroplasty: implant design and orientation.

Authors:  Robert L Barrack
Journal:  J Am Acad Orthop Surg       Date:  2003 Mar-Apr       Impact factor: 3.020

Review 2.  WOMAC: a 20-year experiential review of a patient-centered self-reported health status questionnaire.

Authors:  Nicholas Bellamy
Journal:  J Rheumatol       Date:  2002-12       Impact factor: 4.666

3.  The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties.

Authors:  L I Havelin; L B Engesaeter; B Espehaug; O Furnes; S A Lie; S E Vollset
Journal:  Acta Orthop Scand       Date:  2000-08

4.  Radiological assessment of osteo-arthrosis.

Authors:  J H KELLGREN; J S LAWRENCE
Journal:  Ann Rheum Dis       Date:  1957-12       Impact factor: 19.103

5.  Reduced variability of acetabular cup positioning with use of an imageless navigation system.

Authors:  Michael Nogler; Oliver Kessler; Alexandra Prassl; Bill Donnelly; Robert Streicher; John B Sledge; Martin Krismer
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

6.  L-shaped caliper for limb length measurement during total hip arthroplasty.

Authors:  K Shiramizu; M Naito; T Shitama; Y Nakamura; H Shitama
Journal:  J Bone Joint Surg Br       Date:  2004-09

7.  Total hip replacement in congenital dislocation and dysplasia of the hip.

Authors:  J F Crowe; V J Mani; C S Ranawat
Journal:  J Bone Joint Surg Am       Date:  1979-01       Impact factor: 5.284

8.  Studies in osteoarthritis of the hip. IV. Biomechanics and clinical considerations.

Authors:  J P Gofton
Journal:  Can Med Assoc J       Date:  1971-06-05       Impact factor: 8.262

9.  Arthroplasty of the hip. Leg length is not important.

Authors:  T O White; T W Dougall
Journal:  J Bone Joint Surg Br       Date:  2002-04

10.  Surgical treatment of limb-length discrepancy following total hip arthroplasty.

Authors:  Javad Parvizi; Peter F Sharkey; Gina A Bissett; Richard H Rothman; William J Hozack
Journal:  J Bone Joint Surg Am       Date:  2003-12       Impact factor: 5.284

View more
  23 in total

1.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

3.  A comparison of two different navigated hip replacement techniques on leg length discrepancy.

Authors:  T N Jennison; P Craig; Edward D Davis
Journal:  J Orthop       Date:  2018-02-21

Review 4.  Evidence-based computer-navigated total hip arthroplasty: an updated analysis of randomized controlled trials.

Authors:  Yu-Lin Li; Jun Jia; Qiang Wu; Guang-Zhi Ning; Qiu-Li Wu; Shi-Qing Feng
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-04-16

5.  Hip Offset and Leg Length Equalization in Direct Anterior Approach Total Hip Arthroplasty without Preoperative Templating.

Authors:  Ian Hasegawa; Anne R Wright; Samanth N Andrews; Emily Unebasami; Cass K Nakasone
Journal:  Hawaii J Health Soc Welf       Date:  2019-11

6.  Translatory hip kinematics measured with optoelectronic surgical navigation.

Authors:  Sima Zakani; John F Rudan; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-17       Impact factor: 2.924

7.  Fluoroscopy and imageless navigation enable an equivalent reconstruction of leg length and global and femoral offset in THA.

Authors:  Markus Weber; Michael Woerner; Robert Springorum; Ernst Sendtner; Alexander Hapfelmeier; Joachim Grifka; Tobias Renkawitz
Journal:  Clin Orthop Relat Res       Date:  2014-06-26       Impact factor: 4.176

Review 8.  Leg length correction in computer assisted primary total hip arthroplasty: A collective review of the literature.

Authors:  Jitesh Rajpaul; Mahomed Noor Rasool
Journal:  J Orthop       Date:  2018-03-27

9.  Obesity does not influence acetabular component accuracy when using a 3D optical computer navigation system.

Authors:  Mohamad Sharan; Alex Tang; Lauren Schoof; Alexander Gaukhman; Morteza Meftah; Peter Sculco; Ran Schwarzkopf
Journal:  J Clin Orthop Trauma       Date:  2020-10-03

Review 10.  Navigation in surgery.

Authors:  Uli Mezger; Claudia Jendrewski; Michael Bartels
Journal:  Langenbecks Arch Surg       Date:  2013-02-22       Impact factor: 3.445

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.