Literature DB >> 15446519

L-shaped caliper for limb length measurement during total hip arthroplasty.

K Shiramizu1, M Naito, T Shitama, Y Nakamura, H Shitama.   

Abstract

The existing methods of assessing limb lengthening during total hip arthroplasty (THA) are prone to error because the measurements are not parallel to the limb lengthening axis. In order to address this, we designed a caliper to estimate limb lengthening during THA and evaluated its accuracy compared with our previous device, the straight caliper. Limb lengths were measured in 100 patients. The L-shaped caliper was used in 50 cases and the straight caliper in 50. The correlation between intra-operative and post-operative radiographic measurements was significantly improved using the L-shaped device (p < 0.0001, r = 0.934). This method was extremely accurate in predicting changes in limb length due to surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15446519     DOI: 10.1302/0301-620x.86b7.14587

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  19 in total

1.  [Is shorter really better? : Philosophy of short stem prosthesis designs].

Authors:  J Jerosch
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

3.  A technique to avoid leg-length discrepancy in total hip arthroplasty.

Authors:  M Hossain; A K Sinha
Journal:  Ann R Coll Surg Engl       Date:  2007-04       Impact factor: 1.891

4.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

5.  A new and simple intraoperative method for correction of leg-length discrepancy in total hip arthroplasty.

Authors:  Hiroaki Tagomori; Nobuhiro Kaku; Tomonori Tabata; Hiroshi Tsumura
Journal:  J Orthop       Date:  2019-05-01

6.  [Differences between short stem prostheses].

Authors:  J Jerosch
Journal:  Orthopade       Date:  2014-08       Impact factor: 1.087

7.  Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Authors:  Xing Chen; Shuxing Xing; Zhiyong Zhu; Huisheng Wang; Zhongshen Yu; Xizhuang Bai; Xi Li
Journal:  Front Surg       Date:  2022-03-03

8.  Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-11-11       Impact factor: 3.075

9.  To what extent does leg length discrepancy impair motor activity in patients after total hip arthroplasty?

Authors:  Maria Grazia Benedetti; Fabio Catani; Emanuela Benedetti; Lisa Berti; Annalisa Di Gioia; Sandro Giannini
Journal:  Int Orthop       Date:  2009-09-18       Impact factor: 3.075

10.  Reliability of relation between greater trochanter and center of rotation of femoral head in Indian population.

Authors:  Arvind Kumar; Jigyasa Passey; Mukesh Kumar; Dushyant Chouhan; Manish Saini; Saubhik Das
Journal:  J Clin Orthop Trauma       Date:  2020-04-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.