Low-dose computed tomography of the paranasal sinus and facial skull using a high-pitch dual-source system--first clinical results.

Boris Schell1, Ralf W Bauer, Thomas Lehnert, J Matthias Kerl, Markus Hambek, Angelika May, Thomas J Vogl, Martin G Mack.   

Abstract

OBJECTIVE: Computed tomography (CT) of the paranasal sinus is the standard diagnostic tool for a wide range of indications in mostly younger patients. This study aims to assess the image quality of CT of the sinus by using a high-pitch dual-source technique with special regard to the radiation dose.
METHODS: Examinations were performed on a second-generation dual-source CT with a pitch factor of 3.0 (dual-source mode). Images were compared with those with a pitch factor of 0.9 on the same system (single-source mode) and with those of 16-slice CT. Image quality was evaluated by four blinded readers using a 5-point scale (1=poor, 5=excellent). Comparison of the dose length product (DLP) was used to estimate radiation exposure.
RESULTS: Seventy-three consecutive patients underwent imaging with the proposed CT protocols. The viewers rated the image quality of the dual-source image sets as nearly as good (3.62) as the single-source images on the same device (4.18) and those on 16-slice CT (3.7). DLP was cut to half of the dose [51 mGycm vs. 97.8 mGycm vs. 116.9 mGycm (p<0.01)].
CONCLUSIONS: Using the proposed dual-source mode when examining the paranasal sinus, diagnostic image quality can be achieved while drastically lowering the patient's radiation exposure.

Entities:  

Mesh:

Year:  2010        PMID: 20644936     DOI: 10.1007/s00330-010-1892-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  22 in total

1.  [Radiation exposure during spiral-CT of the paranasal sinuses].

Authors:  F Dammann; E Momino-Traserra; C Remy; P L Pereira; I Baumann; A Koitschev; C D Claussen
Journal:  Rofo       Date:  2000-03

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 3.  [Imaging of paranasal sinuses today].

Authors:  F Dammann
Journal:  Radiologe       Date:  2007-07       Impact factor: 0.635

4.  Pediatric CT radiation dose: how low can you go?

Authors:  Mervyn D Cohen
Journal:  AJR Am J Roentgenol       Date:  2009-05       Impact factor: 3.959

5.  Revised radiation doses for typical X-ray examinations. Report on a recent review of doses to patients from medical X-ray examinations in the UK by NRPB. National Radiological Protection Board.

Authors:  B F Wall; D Hart
Journal:  Br J Radiol       Date:  1997-05       Impact factor: 3.039

6.  [Computerized tomography of paranasal sinuses--a preoperative check list].

Authors:  D Simmen; B Schuknecht
Journal:  Laryngorhinootologie       Date:  1997-01       Impact factor: 1.057

7.  Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique.

Authors:  Wieland H Sommer; Jan C Schenzle; Christoph R Becker; Konstantin Nikolaou; Anno Graser; Gisela Michalski; Klement Neumaier; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2010-02       Impact factor: 6.016

8.  Clinical utility of intraoperative volume computed tomography scanner for endoscopic sinonasal and skull base procedures.

Authors:  Pete S Batra; Seth J Kanowitz; Martin J Citardi
Journal:  Am J Rhinol       Date:  2008 Sep-Oct

9.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

Review 10.  Technical principles of dual source CT.

Authors:  Martin Petersilka; Herbert Bruder; Bernhard Krauss; Karl Stierstorfer; Thomas G Flohr
Journal:  Eur J Radiol       Date:  2008-10-07       Impact factor: 3.528

View more
  17 in total

1.  An education and training programme for radiological institutes: impact on the reduction of the CT radiation dose.

Authors:  Sebastian T Schindera; Reto Treier; Gabriel von Allmen; Claude Nauer; Philipp R Trueb; Peter Vock; Zsolt Szucs-Farkas
Journal:  Eur Radiol       Date:  2011-05-31       Impact factor: 5.315

2.  Letter to the editor re: low-dose computed tomography of the paranasal sinus and facial skull using a high-pitch dual-source system-first clinical results.

Authors:  Wen Jie Yang; Ke Min Chen
Journal:  Eur Radiol       Date:  2011-03-12       Impact factor: 5.315

3.  Letter to the editor re: low-dose computed tomography of the paranasal sinus and facial skull using a high-pitch dual-source system--first clinical results.

Authors:  Stefan Bulla; Philipp Blanke; Mathias Langer; Gregor Pache
Journal:  Eur Radiol       Date:  2011-03-12       Impact factor: 5.315

4.  High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experience.

Authors:  Martin Beeres; Boris Schell; Aristidis Mastragelopoulos; Eva Herrmann; Josef Matthias Kerl; Tatjana Gruber-Rouh; Clara Lee; Petra Siebenhandl; Boris Bodelle; Stephan Zangos; Thomas J Vogl; Volkmar Jacobi; Ralf W Bauer
Journal:  Eur Radiol       Date:  2011-09-14       Impact factor: 5.315

5.  The feasibility of high-pitch acquisition protocol for imaging of the pediatric abdomen by dual-source CT.

Authors:  Eray Atlı; Erhan Akpınar; Emre Ünal; Berna Oğuz Sayan; Mithat Haliloğlu
Journal:  Jpn J Radiol       Date:  2018-05-28       Impact factor: 2.374

Review 6.  New and emerging patient-centered CT imaging and image-guided treatment paradigms for maxillofacial trauma.

Authors:  David Dreizin; Arthur J Nam; Jeffrey Hirsch; Mark P Bernstein
Journal:  Emerg Radiol       Date:  2018-06-20

7.  Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose.

Authors:  M M Lell; M S May; M Brand; A Eller; T Buder; E Hofmann; M Uder; W Wuest
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-26       Impact factor: 3.825

8.  Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

Authors:  J M Hoxworth; D Lal; G P Fletcher; A C Patel; M He; R G Paden; A K Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

9.  Low-tube-voltage 80-kVp neck CT: evaluation of diagnostic accuracy and interobserver agreement.

Authors:  J L Wichmann; J Kraft; E-M Nöske; B Bodelle; I Burck; J-E Scholtz; C Frellesen; J Wagenblast; J M Kerl; R W Bauer; T Lehnert; T J Vogl; B Schulz
Journal:  AJNR Am J Neuroradiol       Date:  2014-08-07       Impact factor: 3.825

10.  Comparing subjective and objective image quality at two different radiation exposure ranges of the paranasal sinus CT examinations using a volumetric 320-row detector CT system.

Authors:  Berhan Pirimoglu; Recep Sade; Muhammed Sedat Sakat; Hayri Ogul; Suat Eren; Mecit Kantarci
Journal:  Dentomaxillofac Radiol       Date:  2017-10-10       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.