Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography.

Ulrike Ropers1, Dieter Ropers, Tobias Pflederer, Katharina Anders, Axel Kuettner, Nikolaos I Stilianakis, Sei Komatsu, Willi Kalender, Werner Bautz, Werner G Daniel, Stephan Achenbach.   

Abstract

OBJECTIVES: We evaluated the influence of heart rate on image quality and diagnostic accuracy of dual-source computed tomography (DSCT) coronary angiography.
BACKGROUND: Multidetector computed tomography (MDCT) coronary angiography has demonstrated an inverse relationship between heart rate and image quality. Dual-source CT provides a higher temporal resolution.
METHODS: One hundred patients were studied by DSCT (DEFINITION, Siemens Medical Solutions, Forchheim, Germany). A contrast-enhanced volume dataset was acquired (two tubes, 120 kV, 400 mAs/rot, collimation 64 x 0.6 mm). Datasets were evaluated concerning the presence of significant coronary stenoses and validated against invasive coronary angiography.
RESULTS: In 44 patients with a heart rate > or =65 beats/min, 566 of 616 coronary segments were evaluable (92%), whereas in 56 patients with a heart rate <65 beats/min, 777 of 778 coronary segments were evaluable (100%, p < 0.001). On a per-patient basis, 93% of patients (> or =65 beats/min) and 100% of patients (<65 beats/min) were considered evaluable. By classifying unevaluable segments as positive for stenosis, per-patient sensitivity was 95% (19 of 20) for heart rates > or =65 beats/min and 100% (22 of 22) for heart rates <65 beats/min. Specificity was 87% (21 of 24) versus 76% (26 of 34), and overall diagnostic accuracy was 91% (40 of 44) versus 86% (48 of 56). None of these differences were statistically significant. Similarly, no difference in diagnostic accuracy was found in per-vessel and -segment analyses.
CONCLUSIONS: In 100 patients studied without beta-blocker pre-medication, DSCT demonstrated slightly lower per-segment evaluability for high heart rates but no decrease in diagnostic accuracy for the detection of coronary artery stenoses.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18154964     DOI: 10.1016/j.jacc.2007.09.017

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  60 in total

1.  Coronary computed tomography angiography in coronary artery disease.

Authors:  Zhonghua Sun; Kwan-Hoong Ng
Journal:  World J Cardiol       Date:  2011-09-26

Review 2.  Coronary CT angiography: clinical utility and prognosis.

Authors:  James K Min; Fay Y Lin; Shahryar Saba
Journal:  Curr Cardiol Rep       Date:  2009-01       Impact factor: 2.931

Review 3.  Radiation dose of cardiac CT--what is the evidence?

Authors:  Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-02-04       Impact factor: 5.315

4.  Image reconstruction and image quality evaluation for a dual source CT scanner.

Authors:  T G Flohr; H Bruder; K Stierstorfer; M Petersilka; B Schmidt; C H McCollough
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  64 Slice multi-detector row cardiac CT.

Authors:  Harpreet K Pannu; Pamela T Johnson; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2008-10-22

6.  Dose reduction in spiral CT coronary angiography with dual source equipment. Part II. Dose surplus due to slope-up and slope-down of prospective tube current modulation in a phantom model.

Authors:  C Martini; A Palumbo; E Maffei; A Rossi; M Rengo; R Malagò; M Dijkshoorn; A Weustink; N Mollet; G Krestin; F Cademartiri
Journal:  Radiol Med       Date:  2010-02       Impact factor: 3.469

7.  Dose reduction in spiral CT coronary angiography with dual-source equipment. Part I. A phantom study applying different prospective tube current modulation algorithms.

Authors:  C Martini; A Palumbo; E Maffei; A Rossi; M Rengo; R Malagò; M Dijkshoorn; A Weustink; N Mollet; G Krestin; F Cademartiri
Journal:  Radiol Med       Date:  2009-08-07       Impact factor: 3.469

8.  Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience.

Authors:  Michael Lell; Mohamed Marwan; Tiziano Schepis; Tobias Pflederer; Katharina Anders; Thomas Flohr; Thomas Allmendinger; Willi Kalender; Dirk Ertel; Carsten Thierfelder; Axel Kuettner; Dieter Ropers; Werner G Daniel; Stephan Achenbach
Journal:  Eur Radiol       Date:  2009-11       Impact factor: 5.315

9.  Impact of heart rate on diagnostic accuracy of second generation 320-detector computed tomography coronary angiography.

Authors:  Nitesh Nerlekar; Brian S Ko; Arthur Nasis; James D Cameron; Michael Leung; Adam J Brown; Dennis T L Wong; Philip J Ngu; John M Troupis; Sujith K Seneviratne
Journal:  Cardiovasc Diagn Ther       Date:  2017-06

10.  Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

Authors:  Julie M Miller; Marc Dewey; Andrea L Vavere; Carlos E Rochitte; Hiroyuki Niinuma; Armin Arbab-Zadeh; Narinder Paul; John Hoe; Albert de Roos; Kunihiro Yoshioka; Pedro A Lemos; David E Bush; Albert C Lardo; John Texter; Jeffery Brinker; Christopher Cox; Melvin E Clouse; João A C Lima
Journal:  Eur Radiol       Date:  2008-11-08       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.