Literature DB >> 22592808

Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease.

Pei Nie1, Ximing Wang, Zhaoping Cheng, Xiaopeng Ji, Yanhua Duan, Jiuhong Chen.   

Abstract

OBJECTIVES: To compare accuracy, image quality and radiation dose between high-pitch spiral and sequential modes on 128-slice dual-source computed tomographic (DSCT) angiography in children with congenital heart disease (CHD).
METHODS: Forty patients suspected with CHD underwent 128-slice DSCT angiography with high-pitch mode and sequential mode respectively. All the anomalies were confirmed by the surgical and/or the conventional cardiac angiography (CCA) findings. The diagnostic accuracy, the subjective and objective image quality and effective radiation doses were compared.
RESULTS: There was no significant difference in diagnostic accuracy (χ ( 2 ) = 0.963, P > 0.05), the objective parameters for image quality (P > 0.05) and the image quality of great vessels (u = 167.500, P > 0.05) between the two groups. The image quality of intracardiac structures and coronary arteries was significantly better in the sequential mode group than that in the high-pitch group (u = 112.500 and 100.000, P < 0.05). The mean effective dose in high-pitch group (0.17 ± 0.05 mSv) was significantly lower (t = 5.287, P < 0.05) than that in the sequential mode group (0.29 ± 0.09 mSv).
CONCLUSIONS: Both the high-pitch and the sequential modes for 128-slice DSCT angiography provide high accuracy for the assessment of CHD in children, while the high-pitch mode, even with some image quality decrease, further significantly lowers the radiation dose. KEY POINTS: • Modern CT provides excellent anatomical detail of congenital heart disease. • Dual source CT systems offer high-pitch spiral and sequential modes. • The high-pitch mode provides high accuracy for the assessment of CHD. • A few images using the high-pitch mode were occasionally slightly degraded. • But the high-pitch mode significantly lowers the radiation dose.

Entities:  

Mesh:

Year:  2012        PMID: 22592808     DOI: 10.1007/s00330-012-2479-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  36 in total

1.  Diagnostic image quality of a comprehensive high-pitch dual-spiral cardiothoracic CT protocol in patients with undifferentiated acute chest pain.

Authors:  Fabian Bamberg; Roy Marcus; Wieland Sommer; Florian Schwarz; Konstantin Nikolaou; Christoph R Becker; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Eur J Radiol       Date:  2010-12-31       Impact factor: 3.528

2.  Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography.

Authors:  Stephan Achenbach; Tobias Goroll; Martin Seltmann; Tobias Pflederer; Katharina Anders; Dieter Ropers; Werner G Daniel; Michael Uder; Michael Lell; Mohamed Marwan
Journal:  JACC Cardiovasc Imaging       Date:  2011-04

3.  Ectopia cordis with tetralogy of Fallot in an infant with pentalogy of Cantrell: high-pitch MDCT exam.

Authors:  Rogerio Santiago-Herrera; Rocio Ramirez-Carmona; Sergio Criales-Vera; Juan Calderon-Colmenero; Eric Kimura-Hayama
Journal:  Pediatr Radiol       Date:  2010-12-22

4.  Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique.

Authors:  Wieland H Sommer; Jan C Schenzle; Christoph R Becker; Konstantin Nikolaou; Anno Graser; Gisela Michalski; Klement Neumaier; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2010-02       Impact factor: 6.016

5.  High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates.

Authors:  Robert Goetti; Gudrun Feuchtner; Paul Stolzmann; Lotus Desbiolles; Michael Alexander Fischer; Christoph Karlo; Stephan Baumueller; Hans Scheffel; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-06-29       Impact factor: 5.315

6.  Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality.

Authors:  Gregor Pache; Jochen Grohmann; Stefan Bulla; Raoul Arnold; Brigitte Stiller; Christian Schlensak; Mathias Langer; Philipp Blanke
Journal:  Eur J Radiol       Date:  2011-02-09       Impact factor: 3.528

7.  Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility.

Authors:  Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen
Journal:  Pediatr Radiol       Date:  2006-10-12

8.  Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease.

Authors:  B Kelly Han; Jana Lindberg; Katharine Grant; Robert S Schwartz; John R Lesser
Journal:  Am J Cardiol       Date:  2011-05-15       Impact factor: 2.778

9.  High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible?

Authors:  Robert Goetti; Stephan Baumüller; Gudrun Feuchtner; Paul Stolzmann; Christoph Karlo; Hatem Alkadhi; Sebastian Leschka
Journal:  AJR Am J Roentgenol       Date:  2010-04       Impact factor: 3.959

10.  Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings.

Authors:  Hyun Woo Goo; Dong-Man Seo; Tae-Jin Yun; Jeong-Jun Park; In-Sook Park; Jae Kon Ko; Young Hwee Kim
Journal:  Pediatr Radiol       Date:  2009-01-22
View more
  27 in total

1.  Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

Authors:  Oliver Rompel; Martin Glöckler; Rolf Janka; Sven Dittrich; Robert Cesnjevar; Michael M Lell; Michael Uder; Matthias Hammon
Journal:  Pediatr Radiol       Date:  2016-01-06

2.  The feasibility of high-pitch acquisition protocol for imaging of the pediatric abdomen by dual-source CT.

Authors:  Eray Atlı; Erhan Akpınar; Emre Ünal; Berna Oğuz Sayan; Mithat Haliloğlu
Journal:  Jpn J Radiol       Date:  2018-05-28       Impact factor: 2.374

3.  Coronary artery visibility in free-breathing young children on non-gated chest CT: impact of temporal resolution.

Authors:  Alexandre Bridoux; Antoine Hutt; Jean-Baptiste Faivre; Thomas Flohr; Alain Duhamel; Julien Pagniez; Jacques Remy; Martine Remy-Jardin
Journal:  Pediatr Radiol       Date:  2015-08-21

Review 4.  Imaging in congenital pulmonary vein anomalies: the role of computed tomography.

Authors:  Kevin Todd Dyer; Anthony Marcus Hlavacek; Felix Gabriel Meinel; Carlo Nicola De Cecco; Andrew Douglas McQuiston; Uwe Joseph Schoepf; Nicholas Peter Pietris
Journal:  Pediatr Radiol       Date:  2014-08-21

5.  A pilot study of a cardiovascular virtual endoscopy system based on multi-detector computed tomography in diagnosing tetralogy of Fallot in pediatric patients.

Authors:  Li-Ping Yao; Li Zhang; Ju Mei; Fang-Bao Ding; Hui-Ming Li; Ming Ding; Xin Yang; Xiao-Ming Li; Kun Sun
Journal:  Exp Ther Med       Date:  2017-11-27       Impact factor: 2.447

6.  Application of low-dose dual-source computed tomography angiography in children with complex congenital heart disease.

Authors:  Xian-Feng Chen; Fan Jiang; Lin Li; Yan Chen; Xin Chen; Yan-Yan Jiang; Li Xiang; Xiao-Jing Ma
Journal:  Exp Ther Med       Date:  2017-06-13       Impact factor: 2.447

7.  ECG-synchronized CT angiography in 324 consecutive pediatric patients: spectrum of indications and trends in radiation dose.

Authors:  Felix G Meinel; Thomas Henzler; U Joseph Schoepf; Patsy W Park; Walter Huda; James V Spearman; Kevin T Dyer; Anil G Rao; Anthony M Hlavacek
Journal:  Pediatr Cardiol       Date:  2014-11-08       Impact factor: 1.655

8.  Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.

Authors:  Wei Zhang; Saivivek Bogale; Farahnaz Golriz; Rajesh Krishnamurthy
Journal:  Pediatr Radiol       Date:  2017-07-25

9.  Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents.

Authors:  Christian A Barrera; Hansel J Otero; Ammie M White; David Saul; David M Biko
Journal:  Int J Cardiovasc Imaging       Date:  2019-01-25       Impact factor: 2.357

10.  Combined prospectively electrocardiography- and respiratory-triggered sequential cardiac computed tomography in free-breathing children: success rate and image quality.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2018-03-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.