Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Philippe Hernigou1, Sebastien Zilber, Paolo Filippini, Alexandre Poignard.   

Abstract

Although ceramic implants have been in use for many years and they are intended to minimize wear debris it is unknown whether alumina-on-alumina or alumina-on-polyethylene produce less wear and osteolysis. We therefore investigated wear and osteolysis on 28 bilateral arthroplasties (one ceramic-ceramic and the contralateral ceramic-polyethylene) of patients who had survived 20 years without revision and without loosening of either hip. Osteolysis was identified on anteroposterior pelvic radiographs and 3-D volume from CT scans. The number of osteolytic lesions detected with CT scan was higher than with radiographs. The number of lesions was higher on the side with the alumina-PE couple. With a similar length of followup on each side, the surface and the volume of osteolysis were consistently higher on the side with the alumina-PE couple. We found no correlation between the volume of osteolysis and the volume of estimated wear in each couple of friction. Hips with osteolysis had a lower Harris score.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19283439      PMCID: PMC2866910          DOI: 10.1007/s11999-009-0773-2

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  36 in total

1.  Ceramic hip prostheses in young patients: a retrospective study of 74 patients.

Authors:  J Fenollosa; P Seminario; C Montijano
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

2.  Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening.

Authors:  J E Nevelos; F Prudhommeaux; M Hamadouche; C Doyle; E Ingham; A Meunier; A B Nevelos; L Sedel; J Fisher
Journal:  J Bone Joint Surg Br       Date:  2001-05

3.  Long-term radiographic assessment of cemented polyethylene acetabular cups.

Authors:  Sophie Williams; Graham Isaac; Neil Porter; John Fisher; John Older
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

4.  Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up.

Authors:  P Hernigou; T Bahrami
Journal:  J Bone Joint Surg Br       Date:  2003-05

5.  Interleukin-6 in the blood of patients with total hip arthroplasty without loosening.

Authors:  P Hernigou; L Intrator; T Bahrami; A Bensussan; J P Farcet
Journal:  Clin Orthop Relat Res       Date:  1999-09       Impact factor: 4.176

6.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

7.  Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study.

Authors:  Moussa Hamadouche; Pierre Boutin; Jacques Daussange; Mark E Bolander; Laurent Sedel
Journal:  J Bone Joint Surg Am       Date:  2002-01       Impact factor: 5.284

8.  Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty.

Authors:  Lalit Puri; Richard L Wixson; Steven H Stern; Joe Kohli; Ronald W Hendrix; S David Stulberg
Journal:  J Bone Joint Surg Am       Date:  2002-04       Impact factor: 5.284

9.  Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results.

Authors:  J A Urban; K L Garvin; C K Boese; L Bryson; D R Pedersen; J J Callaghan; R K Miller
Journal:  J Bone Joint Surg Am       Date:  2001-11       Impact factor: 5.284

10.  Alumina-on-alumina total hip prostheses in patients 40 years of age or younger.

Authors:  P Bizot; L Banallec; L Sedel; R Nizard
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

View more
  18 in total

Review 1.  [Total hip arthroplasty in young patients : Bearings and custom-made prostheses].

Authors:  C Benignus; M Morlock; J Beckmann
Journal:  Orthopade       Date:  2019-04       Impact factor: 1.087

2.  Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum followup study.

Authors:  Hyeong Jo Yoon; Jeong Joon Yoo; Kang Sup Yoon; Kyung-Hoi Koo; Hee Joong Kim
Journal:  Clin Orthop Relat Res       Date:  2012-07-24       Impact factor: 4.176

Review 3.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

4.  Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis.

Authors:  Philippe Hernigou; Jean Charles Auregan; Claire Bastard; Victor Housset; Charles Henri Flouzat-Lachaniette; Arnaud Dubory
Journal:  Int Orthop       Date:  2018-03-04       Impact factor: 3.075

5.  Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors.

Authors:  Philippe Hernigou; Xavier Roussignol; Jerome Delambre; Alexandre Poignard; Charles-Henri Flouzat-Lachaniette
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

6.  Use of morphometry to quantify osteolysis after total hip arthroplasty.

Authors:  Lindsay K Smith; Fiona Cramp; Shea Palmer; Nikki Coghill; Robert F Spencer
Journal:  Clin Orthop Relat Res       Date:  2010-05-12       Impact factor: 4.176

7.  Alumina heads minimize wear and femoral osteolysis progression after isolated simple acetabular revision.

Authors:  Philippe Hernigou; Nicolas Dupuy; Olivier Pidet; Yashuhiro Homma; Charles Henri Flouzat Lachaniette
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

8.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11

10.  Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?

Authors:  Henri Migaud; Sophie Putman; Grégory Kern; Ronald Isida; Julien Girard; Nassima Ramdane; Christian P Delaunay; Moussa Hamadouche
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.