Literature DB >> 11039793

Ceramic hip prostheses in young patients: a retrospective study of 74 patients.

J Fenollosa1, P Seminario, C Montijano.   

Abstract

Zones of osteolysis occur in mobilized and in well-fixed prostheses with the classic ultrahigh molecular weight polyethylene-metal couple. However, since 1981 with the use of the ceramic couple in cemented hip prostheses in young patients, osteolysis has not been observed. The prostheses in patients with a longer followup do not show signs of wear in the bearing or signs of bone lysis in the well-fixed prostheses. Cementless prostheses with the same type of ceramic bearing have been used since 1990 in patients with more than 30 years of life expectancy, in an effort to eliminate loosening at the cement-bone interface. The cementless prostheses performed well with spot welds visible 3 months after the operation, which still are present at 7 years of followup. Lysis has not been observed behind the cup or around the stem. In the current series, head ruptures and accidents in the stem and neck junction produced by the modularity of the prostheses did not occur. The authors focus on the positive results shown by ceramic bearings and describe the results of 31 cemented, five hybrid, and 58 uncemented prostheses with ceramic bearings in patients younger than 50 years of age.

Entities:  

Mesh:

Year:  2000        PMID: 11039793     DOI: 10.1097/00003086-200010000-00009

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  8 in total

1.  Incidence and factors associated with squeaking in alumina-on-alumina THA.

Authors:  Il-Yong Choi; Yee-Suk Kim; Kyu-Tae Hwang; Young-Ho Kim
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

2.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

Review 3.  [Pain management in non-juvenile, aseptic osteonecrosis].

Authors:  M Jäger; A Werner; S Lentrodt; U Mödder; R Krauspe
Journal:  Schmerz       Date:  2004-12       Impact factor: 1.107

4.  Metal on metal hip resurfacing versus uncemented custom total hip replacement--early results.

Authors:  Nemandra A Sandiford; Sarah K Muirhead-Allwood; John A Skinner; Jia Hua
Journal:  J Orthop Surg Res       Date:  2010-02-18       Impact factor: 2.359

5.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

6.  Spontaneous resolution of asymptomatic alumina matrix composite ceramic liner dissociation: a case report.

Authors:  He Xiao; Jian Wang; Nian-Ye Zheng; Zhan-Jun Shi
Journal:  BMC Musculoskelet Disord       Date:  2022-08-20       Impact factor: 2.562

7.  Is wear debris responsible for failure in alumina-on-alumina implants?

Authors:  Lucia Savarino; Nicola Baldini; Gabriela Ciapetti; Andrea Pellacani; Armando Giunti
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

8.  Long-term results of cementless hip arthroplasty with ceramic-on-ceramic articulation.

Authors:  Marek Synder; Marek Drobniewski; Marcin Sibiński
Journal:  Int Orthop       Date:  2012-08-19       Impact factor: 3.075

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.