Literature DB >> 12793553

Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up.

P Hernigou1, T Bahrami.   

Abstract

Although alumina has been used in orthopaedic surgery since the 1970s, the long-term clinical results of zirconia have not been well documented in vivo. We studied hips with these two different ceramics during the same period and with a minimum follow-up of ten years. Because the size of the alumina and zirconia heads was different, hips with 32 mm alumina heads and those with 28 mm zirconia heads were compared with control hips with stainless-steel heads of the same size. Our aim was to compare the two ceramics. There was an increased linear rate of penetration of the femoral heads into the liner between years five and 12 for the zirconia and the stainless-steel groups. This was severe in the zirconia group (0.4 mm/year compared with 0.13 mm/year for the stainless-steel group). During the same 12-year period there was, however, no significant change in the rate of wear in the alumina group (0.07 mm/year). The mean wear at the most recent follow-up was 1360 mm3 for the 28 mm zirconia group, 683 mm3 for the 28 mm stainless-steel group, 755 mm3 for the 32 mm alumina group and 1314 mm3 for the 32 mm stainless-steel group. The monoclinic content rose on the surface of three zirconia heads which were retrieved at revision. This change was associated with an increase in the surface roughness. A change in the roundness with an increase in the sphericity deviation was also observed both in the articular and non-articular parts of the femoral heads. The increase in rate of wear in the zirconia group was only evident after eight years and may be linked to a long-term biodegradation of zirconia in vivo, associated with the altered roughness and roundness which was observed on the retrieved heads.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12793553     DOI: 10.1302/0301-620x.85b4.13397

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  22 in total

1.  Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register.

Authors:  Thomas Kadar; Eva Dybvik; Geir Hallan; Ove Furnes; Leif Ivar Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  On the fracture of a zirconia ball head.

Authors:  C Piconi; G Maccauro; L Pilloni; W Burger; F Muratori; H G Richter
Journal:  J Mater Sci Mater Med       Date:  2006-03       Impact factor: 3.896

Review 3.  Manufacturers affect clinical results of THA with zirconia heads: a systematic review.

Authors:  Hiroyuki Yoshitomi; Satoru Shikata; Hiromu Ito; Takeo Nakayama; Takashi Nakamura
Journal:  Clin Orthop Relat Res       Date:  2009-01-31       Impact factor: 4.176

4.  Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature

Authors:  Xin Yu Mei; Ying Jia Gong; Oleg Safir; Allan Gross; Paul Kuzyk
Journal:  Can J Surg       Date:  2019-08-01       Impact factor: 2.089

5.  Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Authors:  Randy M Cohn; Alejandro González Della Valle; Margaret Peterson; Charles N Cornell
Journal:  HSS J       Date:  2008-07-15

6.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

7.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11

8.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

9.  Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study.

Authors:  Jean Langlois; Samer El Hage; Faouzi Madi; Jean-Pierre Courpied; Marcel Kerboull; Moussa Hamadouche
Journal:  Int Orthop       Date:  2013-01-31       Impact factor: 3.075

10.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.