Long-term radiographic assessment of cemented polyethylene acetabular cups.

Sophie Williams1, Graham Isaac, Neil Porter, John Fisher, John Older.   

Abstract

UNLABELLED: In vitro studies demonstrating excessive wear in polyethylene cups sterilized using gamma irradiation and stored in air led to the abandonment of this sterilization technique. We evaluated the clinical wear performance of a metal femoral component on a polyethylene cup in a hip prosthesis from a selected subset of implants in a group of patients followed for at least 20 years and assessed the time dependency of variation in penetration rates. We measured penetration in 33 polyethylene cups in 25 patients who had a Charnley low-friction arthroplasty between 1982 and 1984. All patients had Charnley Ogee cups implanted for more than 20 years and sterilized using the gamma irradiation in air technique. If degradation occurred over time in vivo, it was not reflected by an increased penetration rate with increasing time in vivo; even after 20 years of implantation, the degree of wear remained low. This suggests gamma irradiation affects wear on ultra-high-molecular-weight polyethylene by reducing wear secondary to the crosslinking, by increasing wear as shown through in vitro studies of heavily oxidized samples, or by oxidation resulting from prolonged shelf life. The effect of progressive oxidation in vivo does not appear to affect wear in vivo. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18196419      PMCID: PMC2505130          DOI: 10.1007/s11999-007-0072-8

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates.

Authors:  P S Barbour; M H Stone; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

Review 2.  The role of macrophages in osteolysis of total joint replacement.

Authors:  Eileen Ingham; John Fisher
Journal:  Biomaterials       Date:  2005-04       Impact factor: 12.479

3.  Rate of wear in total hip replacement.

Authors:  J Charnley; D K Halley
Journal:  Clin Orthop Relat Res       Date:  1975-10       Impact factor: 4.176

4.  Measurement of wear in retrieved acetabular sockets.

Authors:  R M Hall; A Unsworth; P S Craig; C Hardaker; P Siney; B M Wroblewski
Journal:  Proc Inst Mech Eng H       Date:  1995       Impact factor: 1.617

5.  Digital edge-detection measurement of polyethylene wear after total hip arthroplasty.

Authors:  S M Shaver; T D Brown; S L Hillis; J J Callaghan
Journal:  J Bone Joint Surg Am       Date:  1997-05       Impact factor: 5.284

6.  An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups--wear, creep or degradation?

Authors:  G H Isaac; D Dowson; B M Wroblewski
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

7.  Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide.

Authors:  M D Ries; K Weaver; R M Rose; J Gunther; W Sauer; N Beals
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

8.  Overview of polyethylene as a bearing material: comparison of sterilization methods.

Authors:  J P Collier; L C Sutula; B H Currier; J H Currier; R E Wooding; I R Williams; K B Farber; M B Mayor
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

9.  Polyethylene sterilization and production affects wear in total hip arthroplasties.

Authors:  Philip M Faris; Merrill A Ritter; Andrew L Pierce; Kenneth E Davis; Gregory W Faris
Journal:  Clin Orthop Relat Res       Date:  2006-12       Impact factor: 4.176

10.  Socket wear in Charnley low friction arthroplasty of the hip.

Authors:  M J Griffith; M K Seidenstein; D Williams; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1978 Nov-Dec       Impact factor: 4.176

View more
  5 in total

1.  Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study.

Authors:  Bin Chen; Sheng-xiang Xiao; Peng-cheng Gu; Xiang-jin Lin
Journal:  J Zhejiang Univ Sci B       Date:  2010-09       Impact factor: 3.066

2.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

3.  Pseudotumour Complicated by Implant Loosening One Year After revision Ceramic on Metal Total Hip Arthroplasty: A Case Report.

Authors:  Devendra Lakhotia; Prashant Kumar
Journal:  J Orthop Case Rep       Date:  2017 Jan-Feb

4.  Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report.

Authors:  Lokesh Gudda Naik; Won Yong Shon; I C Clarke; Jun-Gyu Moon; Piyush Mukund; Sang-Min Kim
Journal:  Hip Pelvis       Date:  2018-12-06

Review 5.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.