Literature DB >> 11380139

Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening.

J E Nevelos1, F Prudhommeaux, M Hamadouche, C Doyle, E Ingham, A Meunier, A B Nevelos, L Sedel, J Fisher.   

Abstract

We compared and quantified the modes of failure and patterns of wear of 11 Mittelmeier and 11 Ceraver-Ostal retrieved alumina-alumina hip prostheses with reference to the corresponding clinical and radiological histories. Macroscopic wear was assessed using a three-dimensional co-ordinate measuring machine. Talysurf contacting profilometry was used to measure surface roughness on a microscopic scale and SEM to determine mechanisms of wear at the submicron level. The components were classified into one of three categories of wear: low (no visible/measurable wear), stripe (elliptical wear stripe on the heads and larger worn areas on the cups) and severe (macroscopic wear, large volumes of material lost). Overall, the volumetric wear of the alumina-alumina prostheses was substantially less than the widely used metal and ceramic-on-polyethylene combinations. By identifying and eliminating the factors which accelerate wear, it is expected that the lifetime of these devices can be further increased.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11380139

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  14 in total

1.  High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings.

Authors:  J C Keurentjes; R M Kuipers; D J Wever; B W Schreurs
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

2.  Is there a risk in placing a ceramic head on a previously implanted trunion?

Authors:  Didier Hannouche; Jérôme Delambre; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

4.  Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Int Orthop       Date:  2009-09-26       Impact factor: 3.075

5.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

6.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

7.  CORR Insights®: Squeaking Is Common and Increases Over Time Among Patients With Long-term Follow-up After Ceramic-on-ceramic THA.

Authors:  Charles N Cornell
Journal:  Clin Orthop Relat Res       Date:  2021-04-01       Impact factor: 4.176

8.  (v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear.

Authors:  John Fisher; Mazen Al Hajjar; Sophie Williams; Joanne Tipper; Eileen Ingham; Louise Jennings
Journal:  Orthop Trauma       Date:  2012-08

9.  Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions.

Authors:  Mazen Al-Hajjar; John Fisher; Sophie Williams; Joanne L Tipper; Louise M Jennings
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-12-20       Impact factor: 3.368

10.  (iv) Enhancing the safety and reliability of joint replacement implants.

Authors:  Louise M Jennings; Mazen Al-Hajjar; Claire L Brockett; Sophie Williams; Joanne L Tipper; Eileen Ingham; John Fisher
Journal:  Orthop Trauma       Date:  2012-08
View more