Literature DB >> 10627728

Interleukin-6 in the blood of patients with total hip arthroplasty without loosening.

P Hernigou1, L Intrator, T Bahrami, A Bensussan, J P Farcet.   

Abstract

Patients with total hip arthroplasty were screened for the presence of proinflammatory cytokines in the systemic circulation. Only increased levels of interleukin-6 were detected in patients having had total hip arthroplasty more than 10 years ago. These increased levels of interleukin-6 were associated with a decrease in bone mineral density associated with polyethylene wear and with radiologic osteolysis in some patients. These abnormalities were not found in control subjects without total hip arthroplasty or in patients who had a prosthesis in place for less than 6 years. The elevation in interleukin-6 levels found in patients with the oldest prostheses could constitute a marker for periprosthetic osteolysis.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10627728     DOI: 10.1097/00003086-199909000-00018

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  Discovery of biomarkers to identify peri-implant osteolysis before radiographic diagnosis.

Authors:  Ryan D Ross; Youping Deng; Rui Fang; Nicholas B Frisch; Joshua J Jacobs; Dale R Sumner
Journal:  J Orthop Res       Date:  2018-06-05       Impact factor: 3.494

2.  Biological responses of human mesenchymal stem cells to titanium wear debris particles.

Authors:  Hana Haleem-Smith; Evan Argintar; Curtis Bush; Daniel Hampton; William F Postma; Faye H Chen; Todd Rimington; Joshua Lamb; Rocky S Tuan
Journal:  J Orthop Res       Date:  2011-11-14       Impact factor: 3.494

3.  Alumina heads minimize wear and femoral osteolysis progression after isolated simple acetabular revision.

Authors:  Philippe Hernigou; Nicolas Dupuy; Olivier Pidet; Yashuhiro Homma; Charles Henri Flouzat Lachaniette
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  Interaction of Materials and Biology in Total Joint Replacement - Successes, Challenges and Future Directions.

Authors:  J Pajarinen; T-H Lin; T Sato; Z Yao; S B Goodman
Journal:  J Mater Chem B       Date:  2014-11-07       Impact factor: 6.331

5.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

6.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

7.  Serum levels of interleukin 6 (IL-6), granulocyte-macrophage colony-stimulating factor (GM-CSF) and elastase in aseptic prosthetic loosening.

Authors:  Nikolaus A Streich; Steffen J Breusch; Ulrich Schneider
Journal:  Int Orthop       Date:  2003-07-15       Impact factor: 3.075

8.  Multiple biomarkers analysis for the early detection of prosthetic aseptic loosening of hip arthroplasty.

Authors:  Tao He; Wen Wu; Yan Huang; Xiaoling Zhang; Tingting Tang; Kerong Dai
Journal:  Int Orthop       Date:  2013-03-07       Impact factor: 3.075

9.  The central role of wear debris in periprosthetic osteolysis.

Authors:  P Edward Purdue; Panagiotis Koulouvaris; Bryan J Nestor; Thomas P Sculco
Journal:  HSS J       Date:  2006-09

10.  Elevated levels of numerous cytokines in drainage fluid after primary total hip arthroplasty.

Authors:  Huub J L van der Heide; Peter M van der Kraan; Willard J Rijnberg; Pieter Buma; B Willem Schreurs
Journal:  Int Orthop       Date:  2009-08-21       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.