Literature DB >> 30737518

[Total hip arthroplasty in young patients : Bearings and custom-made prostheses].

C Benignus1, M Morlock2, J Beckmann3.   

Abstract

BACKGROUND: Carefully and correctly implanted components are the prerequisite for the lifespan of a prosthesis. Whether higher levels of activity lead to prior failure of total hip arthroplasty in young patients is controversially discussed. The right choice of bearings is still of great relevance. BEARINGS: Ceramic-on-ceramic as well as polyethylene-on-ceramic bearings achieve comparable results, although ceramic-on-ceramic bearings should be avoided in patients with high demands on their range of motion. Polyethylene-on-metal bearings also show good clinical results, if corrosion between head and stem is absent. Metal-on-metal bearings lead to adverse systemic effects due to metal wear and should be implanted in individual cases only, e. g. as hip resurfacing. Alternative bearings have to give proof of effectivity first. Custom-made prostheses constitute an option for young patients with special conditions of hip anatomy. Planning and study results of these prostheses are elucidated in this review article.

Entities:  

Keywords:  Corrosion; THA; Tribology; Wear

Mesh:

Substances:

Year:  2019        PMID: 30737518     DOI: 10.1007/s00132-019-03692-y

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  56 in total

1.  Reduction of wear in total hip replacement prostheses by amorphous diamond coatings.

Authors:  Reijo Lappalainen; Mikko Selenius; Asko Anttila; Yrjö T Konttinen; Seppo S Santavirta
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2003-07-15       Impact factor: 3.368

2.  Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.

Authors:  I C Clarke; V Good; P Williams; D Schroeder; L Anissian; A Stark; H Oonishi; J Schuldies; G Gustafson
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

3.  The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating.

Authors:  M T Raimondi; R Pietrabissa
Journal:  Biomaterials       Date:  2000-05       Impact factor: 12.479

Review 4.  [The importance of wear couples for younger endoprosthesis patients].

Authors:  J Kircher; P Bergschmidt; R Bader; D Kluess; E Besser-Mahuzir; A Leder; W Mittelmeier
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

5.  Use of metal-on-metal total hip resurfacing for the treatment of osteonecrosis of the femoral head.

Authors:  Michael A Mont; Thorsten M Seyler; David R Marker; German A Marulanda; Ronald E Delanois
Journal:  J Bone Joint Surg Am       Date:  2006-11       Impact factor: 5.284

6.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

7.  Custom cementless stem improves hip function in young patients at 15-year followup.

Authors:  Xavier Flecher; Oliver Pearce; Sebastien Parratte; Jean-Manuel Aubaniac; Jean-Noel Argenson
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

Review 8.  [Polyethylene as an implant material].

Authors:  R M Streicher; M Thomsen
Journal:  Orthopade       Date:  2003-01       Impact factor: 1.087

9.  The central role of wear debris in periprosthetic osteolysis.

Authors:  P Edward Purdue; Panagiotis Koulouvaris; Bryan J Nestor; Thomas P Sculco
Journal:  HSS J       Date:  2006-09

10.  Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.

Authors:  G H Isaac; C Brockett; A Breckon; D van der Jagt; S Williams; C Hardaker; J Fisher; A Schepers
Journal:  J Bone Joint Surg Br       Date:  2009-09
View more
  1 in total

1.  Semi-Automated Determination of Heavy Metals in Autopsy Tissue Using Robot-Assisted Sample Preparation and ICP-MS.

Authors:  Heidi Fleischer; Christoph Lutter; Andreas Büttner; Wolfram Mittelmeier; Kerstin Thurow
Journal:  Molecules       Date:  2021-06-23       Impact factor: 4.411

  1 in total