Literature DB >> 18975680

Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator.

Louis Archambault1, Tina Marie Briere, Sam Beddar.   

Abstract

Charge coupled devices (CCDs) are being increasingly used in radiation therapy for dosimetric purposes. However, CCDs are sensitive to stray radiation. This effect induces transient noise. Radiation-induced noise strongly alters the image and therefore limits its quantitative analysis. The purpose of this work is to characterize the radiation-induced noise and to develop filtration algorithms to restore image quality. Two models of CCD were used for measurements close to a medical linac. The structure of the transient noise was first characterized. Then, four methods of noise filtration were compared: median filtering of a time series of identical images, uniform median filtering of single images, an adaptive filter with switching mechanism, and a modified version of the adaptive switch filter. The intensity distribution of noisy pixels was similar in both cameras. However, the spatial distribution of the noise was different: The average noise cluster size was 1.2 +/- 0.6 and 3.2 +/- 2.7 pixels for the U2000 and the Luca, respectively. The median of a time series of images resulted in the best filtration and minimal image distortion. For applications where time series is impractical, the adaptive switch filter must be used to reduce image distortion. Our modified version of the switch filter can be used in order to handle nonisolated groups of noisy pixels.

Entities:  

Mesh:

Year:  2008        PMID: 18975680      PMCID: PMC2736755          DOI: 10.1118/1.2975147

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.

Authors:  Louis Archambault; Jean Arsenault; Luc Gingras; A Sam Beddar; René Roy; Luc Beaulieu
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

2.  The three-dimensional scintillation dosimetry method: test for a 106Ru eye plaque applicator.

Authors:  A S Kirov; J Z Piao; N K Mathur; T R Miller; S Devic; S Trichter; M Zaider; C G Soares; T LoSasso
Journal:  Phys Med Biol       Date:  2005-06-22       Impact factor: 3.609

3.  Development and characterization of a tissue equivalent plastic scintillator based dosimetry system.

Authors:  M P Petric; J L Robar; B G Clark
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

4.  Noise adaptive soft-switching median filter.

Authors:  H L Eng; K K Ma
Journal:  IEEE Trans Image Process       Date:  2001       Impact factor: 10.856

5.  Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications.

Authors:  Fréderic Lacroix; Louis Archambault; Luc Gingras; Mathieu Guillot; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

6.  Fast 2D phantom dosimetry for scanning proton beams.

Authors:  S N Boon; P van Luijk; J M Schippers; H Meertens; J M Denis; S Vynckier; J Medin; E Grusell
Journal:  Med Phys       Date:  1998-04       Impact factor: 4.071

7.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements.

Authors:  A S Beddar; T R Mackie; F H Attix
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

8.  Water-equivalent dosimeter array for small-field external beam radiotherapy.

Authors:  Louis Archambault; A Sam Beddar; Luc Gingras; Fréderic Lacroix; René Roy; Luc Beaulieu
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

  8 in total
  27 in total

1.  Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.

Authors:  L Archambault; F Poenisch; N Sahoo; D Robertson; A Lee; M T Gillin; R Mohan; S Beddar
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam.

Authors:  Rongxiao Zhang; Adam K Glaser; David J Gladstone; Colleen J Fox; Brian W Pogue
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

4.  Real-time in vivo Cherenkoscopy imaging during external beam radiation therapy.

Authors:  Rongxiao Zhang; David J Gladstone; Lesley A Jarvis; Rendall R Strawbridge; P Jack Hoopes; Oscar D Friedman; Adam K Glaser; Brian W Pogue
Journal:  J Biomed Opt       Date:  2013-11       Impact factor: 3.170

5.  Liquid scintillator for 2D dosimetry for high-energy photon beams.

Authors:  Falk Pönisch; Louis Archambault; Tina Marie Briere; Narayan Sahoo; Radhe Mohan; Sam Beddar; Michael T Gillin
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

6.  Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.

Authors:  Sam Beddar; Louis Archambault; Narayan Sahoo; Falk Poenisch; George T Chen; Michael T Gillin; Radhe Mohan
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

7.  Inorganic scintillation detectors based on Eu-activated phosphors for 192Ir brachytherapy.

Authors:  Gustavo Kertzscher; Sam Beddar
Journal:  Phys Med Biol       Date:  2017-05-05       Impact factor: 3.609

8.  A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization.

Authors:  Frédéric Lacroix; A Sam Beddar; Mathieu Guillot; Luc Beaulieu; Luc Gingras
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

9.  Quenching correction for volumetric scintillation dosimetry of proton beams.

Authors:  Daniel Robertson; Dragan Mirkovic; Narayan Sahoo; Sam Beddar
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

10.  Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement.

Authors:  François Therriault-Proulx; Louis Archambault; Luc Beaulieu; Sam Beddar
Journal:  Phys Med Biol       Date:  2012-10-12       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.